77 results for "Alessio, Adam"
Showing 21–40 · 0.24 seconds · RSS
-
Journal Article Full text
The impact of respiratory motion on tumor quantification and delineation in static PET/CT imaging
Our aim is to investigate the impact of respiratory motion on tumor quantification and delineation in static PET/CT imaging using a population of patient respiratory traces. A total of 1295 respiratory traces acquired during whole body PET/CT imaging were classified into three types according to…
-
Journal Article Full text
Validation of an axially distributed model for quantification of myocardial blood flow using (13)N-ammonia PET
BACKGROUND: Estimation of myocardial blood flow (MBF) with cardiac PET is often performed with conventional compartmental models. In this study, we developed and evaluated a physiologically and anatomically realistic axially distributed model. Unlike compartmental models, this axially distributed…
-
Journal Article Full text
Attenuation-emission alignment in cardiac PET∕CT based on consistency conditions
Purpose: In cardiac PET and PET∕CT imaging, misaligned transmission and emission images are a common problem due to respiratory and cardiac motion. This misalignment leads to erroneous attenuation correction and can cause errors in perfusion mapping and quantification. This study develops and tests…
-
Journal Article Full text
Direct Reconstruction of CT-based Attenuation Correction Images for PET with Cluster-Based Penalties
Extremely low-dose CT acquisitions used for PET attenuation correction have high levels of noise and potential bias artifacts due to photon starvation. This work explores the use of a priori knowledge for iterative image reconstruction of the CT-based attenuation map. We investigate a maximum a…
-
Journal Article Full text
Variable temporal sampling and tube current modulation for myocardial blood flow estimation from dose-reduced dynamic computed tomography
Quantification of myocardial blood flow (MBF) can aid in the diagnosis and treatment of coronary artery disease. However, there are no widely accepted clinical methods for estimating MBF. Dynamic cardiac perfusion computed tomography (CT) holds the promise of providing a quick and easy method to…
-
Journal Article Full text
Sinogram smoothing techniques for myocardial blood flow estimation from dose-reduced dynamic computed tomography
Dynamic contrast-enhanced computed tomography (CT) could provide an accurate and widely available technique for myocardial blood flow (MBF) estimation to aid in the diagnosis and treatment of coronary artery disease. However, one of its primary limitations is the radiation dose imparted to the…
-
Journal Article Full text
Mixed Confidence Estimation for Iterative CT Reconstruction
We present a statistical analysis of our previously proposed Constrain-Static Target-Kinetic algorithm for 4D CT reconstruction. This method, where framed iterative reconstruction is only performed on the dynamic regions of each frame, while static regions are fixed across frames to a composite…
-
Journal Article Full text
Morphology supporting function: attenuation correction for SPECT/CT, PET/CT, and PET/MR imaging
Both SPECT, and in particular PET, are unique in medical imaging for their high sensitivity and direct link to a physical quantity, i.e. radiotracer concentration. This gives PET and SPECT imaging unique capabilities for accurately monitoring disease activity for the purposes of clinical management…
-
Journal Article Full text
Mixed Confidence Estimation for Iterative CT Reconstruction
Dynamic (4D) CT imaging is used in a variety of applications, but the two major drawbacks of the technique are its increased radiation dose and longer reconstruction time. Here we present a statistical analysis of our previously proposed Mixed Confidence Estimation (MCE) method that addresses both…
-
Journal Article Full text
Performance Evaluation of Small Animal PET Scanners With Different System Designs
This study evaluated the image quality metrics of small animal PET scanners based upon measured single detector module positioning performance. A semi-analytical approach was developed to study PET scanner performance in the scenario of multiple realizations. Positron range blurring, scanner system…
-
Journal Article Full text
Multiscale modeling of metabolism, flows, and exchanges in heterogeneous organs
Large-scale models accounting for the processes supporting metabolism and function in an organ or tissue with a marked heterogeneity of flows and metabolic rates are computationally complex and tedious to compute. Their use in the analysis of data from positron emission tomography (PET) and…
-
Journal Article Full text
Cine CT for Attenuation Correction in Cardiac PET/CT
In dual-modality PET/CT systems, the CT scan provides the attenuation map for PET attenuation correction. The current clinical practice of obtaining a single helical CT scan provides only a snapshot of the respiratory cycle, whereas PET occurs over multiple respiratory cycles. Misalignment of the…
-
Journal Article Full text
Patient body motion correction for dynamic cardiac PET‐CT by attenuation‐emission alignment according to projection consistency conditions
INTRODUCTION: Patient body motion is known to cause large deviations in the determination of myocardial blood flow (MBF) with errors exceeding 300%. Accurate correction for patient whole‐body motion is still a largely unsolved problem in cardiac positron emission tomography (PET) imaging…
-
Journal Article Full text
Comparison of Blood Flow Models and Acquisitions for Quantitative Myocardial Perfusion Estimation from Dynamic CT
Myocardial blood flow (MBF) can be estimated from dynamic contrast enhanced (DCE) cardiac CT acquisitions leading to quantitative assessment of regional perfusion. The need for low radiation dose and the lack of consensus on MBF estimation methods motivates this study to refine the selection of…
-
Journal Article Full text
Impact on Image Noise of Incorporating Detector Blurring into Image Reconstruction for a Small Animal PET Scanner
We study the noise characteristics of an image reconstruction algorithm that incorporates a model of the non-stationary detector blurring (DB) for a mouse-imaging positron emission tomography (PET) scanner. The algorithm uses ordered subsets expectation maximization (OSEM) image reconstruction…
-
Journal Article Full text
Quiescent period respiratory gating for PET∕CT
Purpose: To minimize respiratory motion artifacts, this work proposes quiescent period gating (QPG) methods that extract PET data from the end-expiration quiescent period and form a single PET frame with reduced motion and improved signal-to-noise properties. Methods: Two QPG methods are proposed…
-
Journal Article Full text
Simulation Evaluation of Quantitative Myocardial Perfusion Assessment from Cardiac CT
Contrast enhancement on cardiac CT provides valuable information about myocardial perfusion and methods have been proposed to assess perfusion with static and dynamic acquisitions. There is a lack of knowledge and consensus on the appropriate approach to ensure 1) sufficient diagnostic accuracy for…
-
Journal Article Full text
Evaluation of static and dynamic perfusion cardiac computed tomography for quantitation and classification tasks
Cardiac computed tomography (CT) acquisitions for perfusion assessment can be performed in a dynamic or static mode. Either method may be used for a variety of clinical tasks, including (1) stratifying patients into categories of ischemia and (2) using a quantitative myocardial blood flow (MBF)…
-
Journal Article Full text
Direct Reconstruction of CT-based Attenuation Correction Images for PET with Cluster-Based Penalties
Extremely low-dose CT acquisitions for the purpose of PET attenuation correction will have a high level of noise and biasing artifacts due to factors such as photon starvation. This work explores a priori knowledge appropriate for CT iterative image reconstruction for PET attenuation correction. We…
-
Journal Article Full text
Optimal kVp Selection for Contrast CT Imaging Based on a Projection-domain Method
Computed Tomography (CT) has been in clinical use for several decades. The number of CT scans has increased significantly worldwide, which results in increased radiation dose delivered to the general population. Many technologies have been developed to minimize the dose from CT scans, including…