72 hasil untuk "Defaye, Pascal"
Menampilkan 21–40 · 2,13 detik · RSS
-
Artikel Jurnal Teks lengkap
Dynamic changes in nocturnal heart rate predict short-term cardiovascular events in patients using the wearable cardioverter-defibrillator: from the WEARIT-France cohort study
AIMS: While elevated resting heart rate measured at a single point of time has been associated with cardiovascular outcomes, utility of continuous monitoring of nocturnal heart rate (NHR) has never been evaluated. We hypothesized that dynamic NHR changes may predict, at short term, impending…
-
Artikel Jurnal Teks lengkap
European experience with a first totally leadless cardiac resynchronization therapy pacemaker system
AIMS: Totally leadless cardiac resynchronization therapy (CRT) can be delivered with a combination of Micra and WiSE-CRT systems. We describe the technical feasibility and first insights into the safety and efficacy of this combination in European experience. METHODS AND RESULTS: Patients enrolled…
-
Artikel Jurnal Teks lengkap
Impact of COVID-19 on the incidence of cardiac arrhythmias in implantable cardioverter defibrillator recipients followed by remote monitoring()
BACKGROUND: The coronavirus disease 2019 (COVID-19) has been a fast-growing worldwide pandemic. AIMS: We aimed to investigate the incidence of cardiac arrhythmias among a large French cohort of implantable cardioverter defibrillator recipients over the first 5 months of 2020. METHODS: Five thousand…
-
Artikel Jurnal Teks lengkap
Role of the Pharmacist in Supporting the Use of Connected Health Devices: Example of Connected Watches
The use of Connected Medical Devices (CMDs) is growing significantly throughout the world. Although they are not dispensed in pharmacies and are not part of the pharmacy-only drug dispensing system, clinical pharmacists must be able to support patients in the use of these new technologies, which…
-
Artikel Jurnal Teks lengkap
Long-term clinical effects of ventricular pacing reduction with a changeover mode to minimize ventricular pacing in a general pacemaker population
AIM: Right ventricular pacing (VP) has been hypothesized to increase the risk in heart failure (HF) and atrial fibrillation (AF). The ANSWER study evaluated, whether an AAI-DDD changeover mode to minimize VP (SafeR) improves outcome compared with DDD in a general dual-chamber pacemaker population…
-
Artikel Jurnal Teks lengkap
Use of drugs with potential cardiac effect in the setting of SARS-CoV-2 infection
-
Artikel Jurnal Teks lengkap
Prospective multicenter randomized trial of fast ventricular tachycardia termination by prolonged versus conventional anti-tachyarrhythmia burst pacing in implantable cardioverter-defibrillator patients-Atp DeliVery for pAiNless ICD thErapy (ADVANCE-D) Trial results
PURPOSE: The purpose of the trial was to quantify and compare the efficacy of two different sequences of burst anti-tachycardia pacing (ATP) strategies for the termination of fast ventricular tachycardia. METHODS: The trial was prospective, multicenter, parallel and randomized, enrolling patients…
-
Artikel Jurnal Teks lengkap
Role of medical reaction in management of inappropriate ventricular arrhythmia diagnosis: the inappropriate Therapy and HOme monitoRiNg (THORN) registry
AIMS: Implantable cardioverter-defibrillators (ICDs) reduce sudden cardiac death in selected patients but inappropriate ICD shocks have been associated with increased mortality. The THORN registry aims to describe the rate of inappropriate ventricular arrhythmia diagnoses and therapies in patients…
-
Artikel Jurnal Teks lengkap
Prognosis assessment of persistent left bundle branch block after TAVI by an electrophysiological and remote monitoring risk-adapted algorithm: rationale and design of the multicentre LBBB–TAVI Study
INTRODUCTION: Percutaneous aortic valve replacement (transcatheter aortic valve implantation (TAVI)) notably increases the likelihood of the appearance of a complete left bundle branch block (LBBB) by direct lesion of the LBB of His. This block can lead to high-grade atrioventricular conduction…
-
Artikel Jurnal Teks lengkap
Technical feasibility of leadless left bundle branch area pacing for cardiac resynchronization: a case series
BACKGROUND: Left bundle branch area pacing (LBBAP) is a novel form of conduction system pacing which can reverse left bundle branch block and deliver cardiac resynchronization therapy (CRT). The WiSE-CRT system delivers leadless endocardial pacing with symptomatic and left ventricular (LV)…
-
Artikel Jurnal Teks lengkap
Management of Rhythm and Conduction Disorders in Cardiac Amyloidosis
BACKGROUND: Cardiac amyloidosis (CA) is an increasingly recognized cardiomyopathy with an associated risk of arrhythmias and conduction disorders; however, managing arrhythmias and conductive disorders remains largely undefined. OBJECTIVES: This study aims to gather French expert experience on…
-
Artikel Jurnal Teks lengkap
Assessment of cardiac resynchronisation therapy in patients with wide QRS and non-specific intraventricular conduction delay: rationale and design of the multicentre randomised NICD-CRT study
INTRODUCTION: Cardiac resynchronisation therapy (CRT) was initially developed to treat patients with left bundle branch block (LBBB). However, many patients with heart failure have a widened QRS but neither left-BBB nor right-BBB; this is called non-specific intraventricular conduction delay…
-
Artikel Jurnal Teks lengkap
A leadless pacemaker in the real‐world setting: Patient profile and performance over time
BACKGROUND: While prior Micra trials demonstrated a high implant success rate and favorable safety and efficacy results, changes in implant populations and safety over time is not well studied. The objective of this analysis was to report the performance of Micra in European and Middle Eastern…
-
Artikel Jurnal Teks lengkap
Validation Against Polysomnography of a Transthoracic Impedance Sensor for Screening of Sleep Apnea in Heart Failure Patients: A Pooled Analysis of AIRLESS and UPGRADE
Background/Introduction: Cardiac implantable electronic devices and their integrated thoracic impedance sensors have been used to detect sleep apnea for over a decade now. Despite their usage in daily clinical practice, there are only limited data on their diagnostic accuracy. Methods: AIRLESS and…
-
Artikel Jurnal Teks lengkap
Multipoint pacing is associated with reduction of heart failure hospitalizations or death in patients who do not respond to cardiac resynchronization therapy: results of the MORE-CRT MPP randomized trial
AIMS: Cardiac resynchronization therapy (CRT) via biventricular pacing (BIVP) is an effective treatment, but non-responders are at a higher risk of death and heart failure (HF) hospitalizations compared with CRT responders. The MORE-CRT MPP trial aimed to evaluate whether CRT with multipoint pacing…
-
Artikel Jurnal Teks lengkap
The learning curve associated with the implantation of the Nanostim leadless pacemaker
PURPOSE: Use of novel medical technologies, such as leadless pacemaker (LP) therapy, may be subjected to a learning curve effect. The objective of the current study was to assess the impact of operators’ experience on the occurrence of serious adverse device effects (SADE) and procedural…
-
Artikel Jurnal Teks lengkap
Preventing atrial fibrillation by combined right isthmus ablation and cryoballoon pulmonary vein isolation in patients with typical atrial flutter: PAF‐CRIOBLAF study
BACKGROUND: Although less common, typical atrial flutter shares similar pathophysiological roots with atrial fibrillation. Following successful cavo‐tricuspid isthmus ablation using radiofrequency, many patients, however, develop atrial fibrillation in the mid‐to‐long‐term. This study sought to…