Biblio Discovery — Demo Discovery Service

72 hasil untuk "Defaye, Pascal"

Menampilkan 41–60 · 0,33 detik · RSS

  1. Artikel Jurnal Teks lengkap

    Outcomes after cryoballoon ablation of paroxysmal atrial fibrillation with the PolarX or the Arctic Front Advance Pro: a prospective multicentre experience

    Tanese, Nikita; Almorad, Alexandre; Pannone, Luigi dkk.

    Europace · 2023 · Inggris · PubMed Central

    AIMS: The aim of this study was to compare procedural efficacy and safety, including 1-year freedom from AF recurrence, between the novel cryoballoon system PolarX (Boston Scientific) and the Arctic Front Advance Pro (AFA-Pro) (Medtronic), in patients with paroxysmal AF undergoing PVI. METHODS AND…

  2. Artikel Jurnal Teks lengkap

    Multipoint pacing is associated with improved prognosis and cardiac resynchronization therapy response: MORE-CRT MPP randomized study secondary analyses

    Calò, Leonardo; De Ruvo, Ermenegildo; Kolb, Christof dkk.

    Europace · 2024 · Inggris · PubMed Central

    AIMS: Cardiac resynchronization therapy (CRT) via biventricular (BIV) pacing is indicated in patients with heart failure (HF), reduced ejection fraction, and prolonged QRS duration. Quadripolar leads and multipoint pacing (MPP) allow multiple left ventricle (LV) sites pacing. We aimed to assess the…

  3. Artikel Jurnal Teks lengkap

    Atrioventricular Synchrony Delivered by a Dual-Chamber Leadless Pacemaker System

    Ip, James E.; Rashtian, Mayer; Exner, Derek V. dkk.

    Circulation · 2024 · Inggris · PubMed Central

    BACKGROUND: A dual-chamber leadless pacemaker system has been designed for atrioventricular synchronous pacing using wireless, beat-to-beat, implant-to-implant (i2i) communication between distinct atrial and ventricular leadless pacemakers. The atrioventricular synchrony achieved across various…

  4. Artikel Jurnal Teks lengkap

    Battery longevity of a helix-fixation dual-chamber leadless pacemaker: results from the AVEIR DR i2i Study

    Reddy, Vivek Y; Doshi, Rahul; Ip, James E dkk.

    Europace · 2025 · Inggris · PubMed Central

    AIMS: A dual-chamber leadless pacemaker (LP) system that employs distinct atrial and ventricular LP devices (ALP, VLP) has been introduced to clinical practice. Proprietary, low-energy, implant-to-implant (i2i) communication at each beat enables the devices to maintain synchronous atrioventricular…

  5. Artikel Jurnal Teks lengkap

    Atrioventricular synchrony maintained by a dual-chamber leadless pacemaker in real-world conditions

    Defaye, Pascal; Reddy, Vivek Y; Ip, James E dkk.

    Europace · 2026 · Inggris · PubMed Central

    AIMS: A dual-chamber leadless pacemaker (LP) system relies on a beat-to-beat, wireless, implant-to-implant (i2i™) communication between implanted devices in the right atrium and right ventricle (A-to-V and V-to-A). Atrioventricular (AV) synchrony was evaluated during an ambulatory 24 h period of…

  6. Artikel Jurnal Teks lengkap

    How is Contact Force implemented in routine clinical practice? Results from a French National and Monaco Survey

    Bun, Sok‐Sithikun; Lațcu, Decebal Gabriel; Taghji, Philippe dkk.

    J Arrhythm · 2019 · Inggris · PubMed Central

    BACKGROUND: Combination of elementary parameters (force, time, power, impedance drop) has been proposed to optimize radiofrequency (RF) delivery. They have been partially validated in clinical studies. AIMS: The aim of this study was to assess contact‐force (CF) implementation into clinical…

  7. Artikel Jurnal Teks lengkap

    Incidence, Characteristics, and Outcomes of Ventricular Fibrillation Complicating Acute Myocardial Infarction in Women Admitted Alive in the Hospital

    Weizman, Orianne; Marijon, Eloi; Narayanan, Kumar dkk.

    J Am Heart Assoc · 2022 · Inggris · PubMed Central

    BACKGROUND: Little data are available in women presenting with ventricular fibrillation (VF) in the setting of acute myocardial infarction (AMI). We assessed frequency, predictors of VF, and outcomes, with a special focus on women compared with men. METHODS AND RESULTS: Data were analyzed from the…

  8. Artikel Jurnal Teks lengkap

    Pre‐emptive treatment of heart failure exacerbations in patients managed with the HeartLogic™ algorithm

    Garcia, Rodrigue; Gras, Daniel; Mansourati, Jacques dkk.

    ESC Heart Fail · 2024 · Inggris · PubMed Central

    AIMS: Heart failure (HF) is a chronic disease affecting 64 million people worldwide and places a severe burden on society because of its mortality, numerous re‐hospitalizations and associated costs. HeartLogic™ is an algorithm programmed into implanted devices incorporating several biometric…

  9. Artikel Jurnal Teks lengkap

    Upgrading expandable leadless pacemakers from single- to dual-chamber

    Bongiorni, Maria Grazia; Doshi, Rahul; Ip, James E dkk.

    Europace · 2026 · Inggris · PubMed Central

    AIMS: The aim of this analysis was to evaluate the upgradeability of a single-chamber leadless pacemaker (LP) to a dual-chamber system in patients indicated for a dual-chamber pacemaker. METHODS AND RESULTS: A prospective, multicentre study evaluated the safety and performance of a dual-chamber LP…

  10. Artikel Jurnal Teks lengkap

    Impact and safety of remote monitoring of heart failure patients managed with the HeartLogic algorithm: the HeartLogic France Cohort Study

    Garcia, Rodrigue; Gras, Daniel; Mansourati, Jacques dkk.

    Eur Heart J Digit Health · 2025 · Inggris · PubMed Central

    AIMS: HeartLogic, an algorithm in implanted devices, predicts heart failure (HF) episodes via a remotely monitored index, aiding proactive congestion treatment to prevent acute decompensation. This study assessed the efficacy and safety of pre-emptive HF management using the HeartLogic index…

  11. Artikel Jurnal Teks lengkap

    Primary Prevention Implantable Cardioverter Defibrillator (ICD) Therapy in Women—Data From a Multicenter French Registry

    Providência, Rui; Marijon, Eloi; Lambiase, Pier D. dkk.

    J Am Heart Assoc · 2016 · Inggris · PubMed Central

    BACKGROUND: There are limited data describing sex specificities regarding implantable cardioverter defibrillators (ICDs) in the real‐world European setting. METHODS AND RESULTS: Using a large multicenter cohort of consecutive patients referred for ICD implantation for primary prevention…

  12. Artikel Jurnal Teks lengkap

    Impact of Body Mass Index on the Outcomes of Catheter Ablation of Atrial Fibrillation: A European Observational Multicenter Study

    Providência, Rui; Adragão, Pedro; de Asmundis, Carlo dkk.

    J Am Heart Assoc · 2019 · Inggris · PubMed Central

    BACKGROUND: Outcomes of catheter ablation of atrial fibrillation (AF) are variable and the predictors of success require further elucidation since the identification of correctable risk factors could help to optimize therapy. We aimed to assess the impact of body mass index (BMI) in the overall…

  13. Artikel Jurnal Teks lengkap

    Real-world experience of leadless left ventricular endocardial cardiac resynchronization therapy: A multicenter international registry of the WiSE-CRT pacing system

    Sieniewicz, Benjamin J.; Betts, Timothy R.; James, Simon dkk.

    Heart Rhythm · 2020 · Inggris · PubMed Central

    BACKGROUND: Biventricular endocardial pacing (BiV ENDO) is a therapy for heart failure patients who cannot receive transvenous epicardial cardiac resynchronization therapy (CRT) or have not responded adequately to CRT. BiV ENDO CRT can be delivered by a new wireless LV ENDO pacing system (WiSE-CRT…

  14. Artikel Jurnal Teks lengkap

    Leadless Ultrasound-Based Cardiac Resynchronization System in Heart Failure

    Singh, Jagmeet P.; Rinaldi, Christopher A.; Sanders, Prashanthan dkk.

    JAMA Cardiol · 2024 · Inggris · PubMed Central

    IMPORTANCE: Approximately 40% of patients with heart failure (HF) who are eligible for cardiac resynchronization therapy (CRT) either fail to respond or are untreatable due to anatomical constraints. OBJECTIVE: To assess the safety and efficacy of a novel, leadless, left ventricular (LV)…

  15. Artikel Jurnal Teks lengkap

    Catheter Ablation of Atrial Fibrillation in Patients with Previous Lobectomy or Partial Lung Resection: Long-Term Results of an International Multicenter Study

    Demarchi, Andrea; Conte, Giulio; Chen, Shih-Ann dkk.

    J Clin Med · 2022 · Inggris · PubMed Central

    Introduction: Data regarding the efficacy of catheter ablation in patients with atrial fibrillation (AF) and patients’ previous history of pulmonary lobectomy/pneumonectomy are scanty. We sought to evaluate the efficacy and long-term follow-up of catheter ablation in this highly selected group of…

  16. Artikel Jurnal Teks lengkap

    European Society of Cardiology Quality Indicators for the care and outcomes of cardiac pacing: developed by the Working Group for Cardiac Pacing Quality Indicators in collaboration with the European Heart Rhythm Association of the European Society of Cardiology

    Aktaa, Suleman; Abdin, Amr; Arbelo, Elena dkk.

    Europace · 2021 · Inggris · PubMed Central

    AIMS: To develop a suite of quality indicators (QIs) for the evaluation of the care and outcomes for adults undergoing cardiac pacing. METHODS AND RESULTS: Under the auspice of the Clinical Practice Guideline Quality Indicator Committee of the European Society of Cardiology (ESC), the Working Group…

  17. Artikel Jurnal Teks lengkap

    Management of patients with transvalvular right ventricular leads undergoing transcatheter tricuspid valve interventions: a scientific statement of the European Heart Rhythm Association and the European Association of Percutaneous Cardiovascular Interventions of the ESC endorsed by the Heart Rhythm Society, the Asian Pacific Heart Rhythm Society and the Canadian Heart Rhythm Society

    Deharo, Jean-Claude; Dreyfus, Julien; Bongiorni, Maria-Grazia dkk.

    Europace · 2025 · Inggris · PubMed Central

    Up to one-third of patients referred for transcatheter tricuspid valve intervention (TTVI) have a transvalvular pacemaker (PPM) or implantable cardioverter-defibrillator (ICD) lead in place. Both the electrophysiology and interventional cardiology communities have been alerted to the complexity of…

    Juga tersedia di: PubMed Central

  18. Artikel Jurnal Teks lengkap

    Amplified sinus-P-wave analysis predicts outcomes of cryoballoon ablation in patients with persistent and long-standing persistent atrial fibrillation: A multicentre study

    Creta, Antonio; Venier, Sandrine; Tampakis, Konstantinos dkk.

    Front Cardiovasc Med · 2023 · Inggris · PubMed Central

    INTRODUCTION: Outcomes of catheter ablation for non-paroxysmal atrial fibrillation (AF) remain suboptimal. Non-invasive stratification of patients based on the presence of atrial cardiomyopathy (ACM) could allow to identify the best responders to pulmonary vein isolation (PVI). METHODS…

  19. Artikel Jurnal Teks lengkap

    Real-world experience with the pentaspline pulsed field ablation system: one-year outcomes of the FARADISE registry

    Boersma, Lucas V A; Széplaki, Gábor; Dello Russo, Antonio dkk.

    Europace · 2025 · Inggris · PubMed Central

    AIMS: Clinical studies with protocol-mandated workflow and monitoring have analysed performance of pulsed field ablation (PFA) for treating atrial fibrillation (AF). The FARADISE registry captures global use of the pentaspline PFA catheter in real-world clinical practice with a follow-up of 3…