Spatially Variant Positron Range Modeling Derived from CT for PET Image Reconstruction
The influence of a finite positron annihilation distance represents a fundamental limit to the spatial resolution of PET scanners. It is appreciated that this effect is a minor concern in whole-body F18 imaging, but it does represent an issue when imaging with higher energy isotopes such as N13 or…
-
Artikel Jurnal Teks lengkap
What are the basic concepts of temporal, contrast, and spatial resolution in cardiac CT?
An imaging instrument can be characterized by its spatial resolution, contrast resolution, and temporal resolution. The capabilities of computed tomography (CT) relative to other cardiac imaging modalities can be understood in these terms. The purpose of this review is to characterize the spatial…
-
Artikel Jurnal Teks lengkap
Multi-Objective Evolutionary Algorithm for PET Image Reconstruction: Concept
In many diagnostic imaging settings, including positron emission tomography (PET), images are typically used for multiple tasks such as detecting disease and quantifying disease. Unlike conventional image reconstruction that optimizes a single objective, this work proposes a multi-objective…
-
Artikel Jurnal Teks lengkap
Quantitative material characterization from multi-energy photon counting CT
Purpose: To quantify the concentration of soft-tissue components of water, fat, and calcium through the decomposition of the x-ray spectral signatures in multi-energy CT images. Methods: Decomposition of dual-energy and multi-energy x-ray data into basis materials can be performed in the projection…
-
Artikel Jurnal Teks lengkap
Consistency Driven Respiratory Phase Alignment and Motion Compensation in PET/CT
Respiratory motion in PET/CT imaging degrades PET image quantitation due to misaligned attenuation correction (AC) factors and motion blurring. This work explores the use of the Radon consistency conditions to compensate for these limitations in respiratory gated PET images in which only a single…
-
Artikel Jurnal Teks lengkap
APPLICATION OF A SPATIALLY VARIANT SYSTEM MODEL FOR 3-D WHOLE-BODY PET IMAGE RECONSTRUCTION
Accurate system modeling in tomographic image reconstruction has been shown to reduce the spatial variance of resolution and improve quantitative accuracy. System modeling can be improved through analytic calculations, Monte Carlo simulations, and physical measurements. This work presents a novel…
-
Artikel Jurnal Teks lengkap
Statistical image reconstruction from correlated data with applications to PET
Most statistical reconstruction methods for emission tomography are designed for data modeled as conditionally independent Poisson variates. In reality, due to scanner detectors, electronics and data processing, correlations are introduced into the data resulting in dependent variates. In general…
-
Artikel Jurnal Teks lengkap
Dual energy CT for attenuation correction with PET/CT
Purpose: The authors evaluate the energy dependent noise and bias properties of monoenergetic images synthesized from dual-energy CT (DECT) acquisitions. These monoenergetic images can be used to estimate attenuation coefficients at energies suitable for positron emission tomography (PET) and…
-
Artikel Jurnal Teks lengkap
Respiratory motion correction for quantitative PET∕CT using all detected events with internal—external motion correlation
Purpose: We present a method to correct respiratory motion blurring in PET∕CT imaging using internal–external (INTEX) motion correlation. The internal motion of a known tumor is derived from respiratory-gated PET images; this internal motion is then correlated with external respiratory signals to…
-
Artikel Jurnal Teks lengkap
Evaluation of Noise Properties in PSF-Based PET Image Reconstruction
The addition of accurate system modeling in PET image reconstruction results in images with distinct noise texture and characteristics. In particular, the incorporation of point spread functions (PSF) into the system model has been shown to visually reduce image noise, but the noise properties have…
-
Artikel Jurnal Teks lengkap
Noise and Bias Properties of Monoenergetic Images from DECT used for Attenuation Correction with PET/CT and SPECT/CT
We evaluate the energy dependent noise and bias properties of monoenergetic images synthesized from dual-energy CT (DECT) acquisitions used to estimate attenuation coefficients at PET or SPECT energies. This is becoming more relevant with the increased used of quantitative imaging by PET/CT and…
-
Artikel Jurnal Teks lengkap
Limits of Ultra-Low Dose CT Attenuation Correction for PET/CT
We present an analysis of the effects of ultra-low dose X-ray computerized tomography (CT) based attenuation correction for positron emission tomography (PET). By ultra low dose we mean less than approximately 5 mAs or 0.5 mSv total effective whole body dose. The motivation is the increased…
-
Artikel Jurnal Teks lengkap
Image reconstruction for PET/CT scanners: past achievements and future challenges
PET is a medical imaging modality with proven clinical value for disease diagnosis and treatment monitoring. The integration of PET and CT on modern scanners provides a synergy of the two imaging modalities. Through different mathematical algorithms, PET data can be reconstructed into the spatial…
-
Artikel Jurnal Teks lengkap
Quantitative Myocardial Perfusion from Static Cardiac and Dynamic Arterial CT
Quantitative myocardial blood flow (MBF) estimation by dynamic contrast enhanced cardiac computed tomography (CT) requires multi-frame acquisition of contrast transit through the blood pool and myocardium to inform the arterial input and tissue response functions. Both the input and the tissue…
-
Artikel Jurnal Teks lengkap
Relationships of Pediatric Anthropometrics for CT Protocol Selection
OBJECTIVE: Determining the optimal CT technique to minimize patient radiation exposure while maintaining diagnostic utility requires patient-specific protocols that are based on patient characteristics. This work develops relationships between different anthropometrics and CT image noise to…
-
Artikel Jurnal Teks lengkap
Phantom and Methodology for Comparison of Small Lesion Detectability in PET
PURPOSE: The main goal of this work is to describe a phantom design, data acquisition and data analysis methodology enabling comparison of small lesion detectability between PET imaging systems and reconstruction algorithms. Several methods are currently available to characterize intrinsic and…
-
Artikel Jurnal Teks lengkap
Detector Position Estimation for PET Scanners
Physical positioning of scintillation crystal detector blocks in Positron Emission Tomography (PET) scanners is not always exact. We test a proof of concept methodology for the determination of the six degrees of freedom for detector block positioning errors by utilizing a rotating point source…
-
Artikel Jurnal Teks lengkap
Determining Block Detector Positions for PET Scanners
We present an algorithm for accurate localization of block detectors in a positron emission tomography (PET) scanner. Accurate reconstruction of PET images requires precise knowledge of the physical position and orientation of the detectors. However, in some systems, block detector positioning and…
-
Artikel Jurnal Teks lengkap
Analysis pipeline to quantify uterine gland structural variations
BACKGROUND: Technical advances in whole tissue imaging and clearing have allowed 3D reconstruction of exocrine uterine glands deep‐seated in the endometrium. However, there are limited gland structure analysis platforms to analyze these imaging data sets. Here, we present a pipeline for segmenting…
-
Artikel Jurnal Teks lengkap
Quantitative imaging of coronary blood flow
Positron emission tomography (PET) is a nuclear medicine imaging modality based on the administration of a positron-emitting radiotracer, the imaging of the distribution and kinetics of the tracer, and the interpretation of the physiological events and their meaning with respect to health and…