108 results for "Alizad, Azra"
Showing 1–20 · 0.23 seconds · RSS
-
Journal Article Full text
Adaptive Background Noise Bias Suppression in Contrast-free Ultrasound Microvascular Imaging
Non-invasive, contrast-free imaging of small vessel blood flow is diagnostically invaluable for detection, diagnosis and monitoring of disease. Recent advances in ultrafast imaging and tissue clutter-filtering have considerably improved the sensitivity of power Doppler (PD) imaging in detecting…
-
Journal Article Full text
Fast inter-frame motion correction in contrast-free ultrasound quantitative microvasculature imaging using deep learning
Contrast-free ultrasound quantitative microvasculature imaging shows promise in several applications, including the assessment of benign and malignant lesions. However, motion represents one of the major challenges in imaging tumor microvessels in organs that are prone to physiological motions…
-
Journal Article Full text
Artificial intelligence techniques in liver cancer
Hepatocellular Carcinoma (HCC), the most common primary liver cancer, is a significant contributor to worldwide cancer-related deaths. Various medical imaging techniques, including computed tomography, magnetic resonance imaging, and ultrasound, play a crucial role in accurately evaluating HCC and…
-
Journal Article Full text
Background Noise Removal in Non-Contrast- Enhanced Ultrasound Microvasculature Imaging Using Combined Collaborative, Morphological, and Vesselness Filtering
Suppression of background noise in clutter filtered contrast-free ultrasound microvasculature images is an important step towards better visualization, accurate segmentation, and subsequent morphological analysis of vascular structures. While different approaches to tackling this problem have been…
-
Journal Article Full text
Vibro-acoustography and Multifrequency Image Compounding
Vibro-acoustography is an ultrasound based imaging modality that can visualize normal and abnormal soft tissue through mapping the acoustic response of the object to a harmonic radiation force at frequency Δf induced by focused ultrasound. In this method, the ultrasound energy is converted from…
-
Journal Article Full text
Non-Local Based Denoising Framework for In Vivo Contrast-Free Ultrasound Microvessel Imaging
Vascular networks can provide invaluable information about tumor angiogenesis. Ultrafast Doppler imaging enables ultrasound to image microvessels by applying tissue clutter filtering methods on the spatio-temporal data obtained from plane-wave imaging. However, the resultant vessel images suffer…
-
Journal Article Full text
Ultrasound characterization of bone demineralization using a support vector machine
In this work, we propose an ultrasound-guided remote measurement technique, utilizing an acoustic radiation force (ARF) beam as our excitation source and a receiving hydrophone, to noninvasively assess a bone’s mechanical properties. Features, such as velocity, were extracted from the received…
-
Journal Article Full text
Quantification of Morphological Features in Non-Contrast-Enhanced Ultrasound Microvasculature Imaging
There are significant differences in microvascular morphological features in diseased tissues, such as cancerous lesions, compared to noncancerous tissue. Quantification of microvessel morphological features could play an important role in disease diagnosis and tumor classification. However…
-
Journal Article Full text
Custom-made Flow Phantoms for Quantitative Ultrasound Microvessel Imaging
Morphologically realistic flow phantoms are essential experimental tools for quantitative ultrasound-based microvessel imaging. As new quantitative flow imaging tools are developed, the need for more complex vessel-mimicking phantoms is indisputable. In this article, we propose a method for…
-
Journal Article Full text
Complex Background Suppression for Vibro-acoustography Images
Vibro-acoustography (VA) is an ultrasound-based imaging modality that maps the acoustic response, or acoustic emission, of an object stimulated by two ultrasound waves at slightly different frequencies. VA images typically have a nonzero background intensity which can reduce contrast in images. We…
-
Journal Article Full text
Gap-filling method for suppressing grating lobes in ultrasound imaging: Theory and simulation results
Sparse array (SA) is an approach to reduce the number of system channels. However, SA suffers from grating lobe (GL) artefacts due to the sparsity of array aperture resulting in degradation of the ultrasound image quality. Based on a given or known data sets of radio frequency (RF) echo acquired…
-
Journal Article Full text
Deep Learning in Different Ultrasound Methods for Breast Cancer, from Diagnosis to Prognosis: Current Trends, Challenges, and an Analysis
SIMPLE SUMMARY: Breast cancer is one of the leading causes of cancer death among women. Ultrasound is a harmless imaging modality used to help make decisions about who should undergo biopsies and several aspects of breast cancer management. It shows high false positivity due to high operator…
-
Journal Article Full text
Deep learning based motion correction in ultrasound microvessel imaging approach improves thyroid nodule classification
To address inter-frame motion artifacts in ultrasound quantitative high-definition microvasculature imaging (qHDMI), we introduced a novel deep learning-based motion correction technique. This approach enables the derivation of more accurate quantitative biomarkers from motion-corrected HDMI…
-
Journal Article Full text
Artifacts in Urodynamic Studies: A Narrative Review
BACKGROUND: Urodynamic studies (UDS) are integral to the evaluation and management of lower urinary tract dysfunction. However, artifacts are frequently encountered, affecting both clinical interpretation and research reliability. OBJECTIVE: This expert narrative review examines the prevalence…
-
Journal Article Full text
Image Features in Medical Vibro-acoustography: In Vitro and in Vivo Results
Vibro-acoustography is an imaging method based on audio-frequency harmonic vibrations induced in the object by the radiation force of focused ultrasound. The purpose of this study is to investigate features of vibro-acoustography images and manifestation of various tissue structures and…
-
Journal Article Full text
Non-invasive small vessel imaging of human thyroid using motion-corrected spatiotemporal clutter filtering
Reliable assessment of small vessel blood flow in thyroid, without using any contrast agents, can be challenging due to increased physiological motion as a consequence of its proximity to the pulsating carotid artery. In this study, we hypothesized that correction of tissue motion prior to singular…
-
Journal Article Full text
Impact of imaging cross-section on visualization of thyroid microvessels using ultrasound: Pilot study
Non-invasive, contrast-free microvascular imaging of human thyroids can be potentially beneficial in reducing the large number of benign biopsies of suspicious nodules. However, motion incurred by thyroid due to its proximity to the pulsating carotid artery significantly impacts the visualization…
-
Journal Article Full text
Non-Invasive Measurement of the Internal Pressure of a Pressurized Biological Compartment Using Lamb Waves
In this study, we propose a mechanical analysis for estimating the internal pressure of a finitely deformed spherical compartment from Lamb wave measurements. The proposed analysis produces a dispersion relation associating Lamb wave speed with pressure using limited material parameters (only a…
-
Journal Article Full text
DMAeEDNet: Dense Multiplicative Attention Enhanced Encoder Decoder Network for Ultrasound-Based Automated Breast Lesion Segmentation
Automated and precise segmentation of breast lesions can facilitate early diagnosis of breast cancer. Recent research studies employ deep learning for automatic segmentation of breast lesions using ultrasound imaging. Numerous studies introduce somewhat complex modifications to the well adapted…