Biblio Discovery — Demo Discovery Service

28 results for "Ang, Wei Tech"

Showing 1–20 · 0.71 seconds · RSS

  1. Journal Article Full text

    Estimation of Physiological Tremor from Accelerometers for Real-Time Applications

    Veluvolu, Kalyana C.; Ang, Wei Tech

    Sensors (Basel) · 2011 · English · PubMed Central

    Accurate filtering of physiological tremor is extremely important in robotics assisted surgical instruments and procedures. This paper focuses on developing single stage robust algorithms for accurate tremor filtering with accelerometers for real-time applications. Existing methods rely on…

  2. Journal Article Full text

    Multi-Camera Calibration Using Far-Range Dual-LED Wand and Near-Range Chessboard Fused in Bundle Adjustment

    Jatesiktat, Prayook; Lim, Guan Ming; Ang, Wei Tech

    Sensors (Basel) · 2024 · English · PubMed Central

    This paper presents a calibration approach for multiple synchronized global-shutter RGB cameras surrounding a large capture volume for 3D application. The calibration approach uses an active wand with two LED-embedded markers waved manually within the target capture volume. Data from the waving…

  3. Journal Article Full text

    Drift-Free Position Estimation of Periodic or Quasi-Periodic Motion Using Inertial Sensors

    Latt, Win Tun; Veluvolu, Kalyana Chakravarthy; Ang, Wei Tech

    Sensors (Basel) · 2011 · English · PubMed Central

    Position sensing with inertial sensors such as accelerometers and gyroscopes usually requires other aided sensors or prior knowledge of motion characteristics to remove position drift resulting from integration of acceleration or velocity so as to obtain accurate position estimation. A method based…

  4. Journal Article Full text

    Real-Time Foot Tracking and Gait Evaluation with Geometric Modeling

    Foo, Ming Jeat; Chang, Jen-Shuan; Ang, Wei Tech

    Sensors (Basel) · 2022 · English · PubMed Central

    Gait evaluation is important in gait rehabilitation and assistance to monitor patient’s balance status and assess recovery performance. Recent technologies leverage on vision-based systems with high portability and low operational complexity. In this paper, we propose a new vision-based foot…

  5. Journal Article Full text

    A Modified Prandtl–Ishlinskii Hysteresis Model for Modeling and Compensating Asymmetric Hysteresis of Piezo-Actuated Flexure-Based Systems

    Zhou, Chao; Yuan, Meng; Feng, Chen et al.

    Sensors (Basel) · 2022 · English · PubMed Central

    Piezo-actuated flexure-based systems are widely used in applications with high accuracy requirements, but the intrinsic hysteresis has a detrimental effect on the performance which should be compensated. Conventional models were presented to model this undesired effect using additional dead-zone…

  6. Journal Article Full text

    Automatic Identification of Systolic Time Intervals in Seismocardiogram

    Shafiq, Ghufran; Tatinati, Sivanagaraja; Ang, Wei Tech et al.

    Sci Rep · 2016 · English · PubMed Central

    Continuous and non-invasive monitoring of hemodynamic parameters through unobtrusive wearable sensors can potentially aid in early detection of cardiac abnormalities, and provides a viable solution for long-term follow-up of patients with chronic cardiovascular diseases without disrupting the daily…

  7. Journal Article Full text

    A Digitized Representation of the Modified Prandtl–Ishlinskii Hysteresis Model for Modeling and Compensating Piezoelectric Actuator Hysteresis

    Zhou, Chao; Feng, Chen; Aye, Yan Naing et al.

    Micromachines (Basel) · 2021 · English · PubMed Central

    Piezoelectric actuators are widely used in micromanipulation and miniature robots due to their rapid response and high repeatability. The piezoelectric actuators often have undesired hysteresis. The Prandtl–Ishlinskii (PI) hysteresis model is one of the most popular models for modeling and…

  8. Journal Article Full text

    Analysis of Accuracy in Pointing with Redundant Hand-held Tools: A Geometric Approach to the Uncontrolled Manifold Method

    Campolo, Domenico; Widjaja, Ferdinan; Xu, Hong et al.

    PLoS Comput Biol · 2013 · English · PubMed Central

    This work introduces a coordinate-independent method to analyse movement variability of tasks performed with hand-held tools, such as a pen or a surgical scalpel. We extend the classical uncontrolled manifold (UCM) approach by exploiting the geometry of rigid body motions, used to describe tool…

  9. Journal Article Full text

    ExTraCT – Explainable trajectory corrections for language-based human-robot interaction using textual feature descriptions

    Yow, J-Anne; Garg, Neha Priyadarshini; Ramanathan, Manoj et al.

    Front Robot AI · 2024 · English · PubMed Central

    INTRODUCTION: In human-robot interaction (HRI), understanding human intent is crucial for robots to perform tasks that align with user preferences. Traditional methods that aim to modify robot trajectories based on language corrections often require extensive training to generalize across diverse…

  10. Journal Article Full text

    Fall inducing movable platform (FIMP) for overground trips and slips

    Er, Jie Kai; Donnelly, Cyril John William; Wee, Seng Kwee et al.

    J Neuroeng Rehabil · 2020 · English · PubMed Central

    BACKGROUND: The study of falls and fall prevention/intervention devices requires the recording of true falls incidence. However, true falls are rare, random, and difficult to collect in real world settings. A system capable of producing falls in an ecologically valid manner will be very helpful in…

  11. Journal Article Full text

    Autonomous modeling of repetitive movement for rehabilitation exercise monitoring

    Jatesiktat, Prayook; Lim, Guan Ming; Kuah, Christopher Wee Keong et al.

    BMC Med Inform Decis Mak · 2022 · English · PubMed Central

    BACKGROUND: Insightful feedback generation for daily home-based stroke rehabilitation is currently unavailable due to the inefficiency of exercise inspection done by therapists. We aim to produce a compact anomaly representation that allows a therapist to pay attention to only a few specific…

  12. Journal Article Full text

    Feedforward Controller of Ill-Conditioned Hysteresis Using Singularity-Free Prandtl–Ishlinskii Model

    Tan, U-Xuan; Latt, Win Tun; Shee, Cheng Yap et al.

    IEEE ASME Trans Mechatron · 2009 · English · PubMed Central

    Piezoelectric, magnetostrictive, and shape memory alloy actuators are gaining importance in high-frequency precision applications constrained by space. Their intrinsic hysteretic behavior makes control difficult. The Prandtl–Ishlinskii (PI) operator can model hysteresis well, albeit a major…

  13. Journal Article Full text

    Compact Sensing Design of a Handheld Active Tremor Compensation Instrument

    Latt, Win Tun; Tan, U-Xuan; Shee, Cheng Yap et al.

    IEEE Sens J · 2009 · English · PubMed Central

    Active physiological tremor compensation instruments have been under research and development recently. The sensing unit of the instruments provides information on three degrees-of-freedom (DOF) motion of the instrument tip using accelerations provided by accelerometers placed inside the…

  14. Journal Article Full text

    Robotic-based ACTive somatoSENSory (Act.Sens) retraining on upper limb functions with chronic stroke survivors: study protocol for a pilot randomised controlled trial

    Sidarta, Ananda; Lim, Yu Chin; Kuah, Christopher Wee Keong et al.

    Pilot Feasibility Stud · 2021 · English · PubMed Central

    BACKGROUND: Prior studies have established that senses of the limb position in space (proprioception and kinaesthesia) are important for motor control and learning. Although nearly one-half of stroke patients have impairment in the ability to sense their movements, somatosensory retraining focusing…

  15. Journal Article Full text

    Learning-Based Motion-Intention Prediction for End-Point Control of Upper-Limb-Assistive Robots

    Yang, Sibo; Garg, Neha P.; Gao, Ruobin et al.

    Sensors (Basel) · 2023 · English · PubMed Central

    The lack of intuitive and active human–robot interaction makes it difficult to use upper-limb-assistive devices. In this paper, we propose a novel learning-based controller that intuitively uses onset motion to predict the desired end-point position for an assistive robot. A multi-modal sensing…

  16. Journal Article Full text

    Relearning Upper Limb Proprioception After Stroke Through Robotic Therapy: A Feasibility Analysis

    Sidarta, Ananda; Lim, Yu Chin; Kuah, Christopher Wee Keong et al.

    J Clin Med · 2025 · English · PubMed Central

    Background: Motor learning can occur through active reaching with the arm hidden from view, leading to improvements in somatosensory acuity and modulation of functional connectivity in sensorimotor and reward networks. In this proof-of-principle study, we assess if the same paradigm benefits stroke…

  17. Journal Article Full text

    A Micro Motion Sensing System for Micromanipulation Tasks

    Latt, Win Tun; Tan, U-Xuan; Georgiou, Andreas et al.

    Sens Actuators A Phys · 2012 · English · PubMed Central

    An optical-based motion sensing system has been developed for real-time sensing of instrument motion in micromanipulation. The main components of the system consist of a pair of position sensitive detectors (PSD), lenses, an infrared (IR) diode that illuminates the workspace of the system, a…

  18. Journal Article Full text

    Tracking Control of Hysteretic Piezoelectric Actuator using Adaptive Rate-Dependent Controller

    Tan, U-Xuan; Latt, Win Tun; Widjaja, Ferdinan et al.

    Sens Actuators A Phys · 2009 · English · PubMed Central

    With the increasing popularity of actuators involving smart materials like piezoelectric, control of such materials becomes important. The existence of the inherent hysteretic behavior hinders the tracking accuracy of the actuators. To make matters worse, the hysteretic behavior changes with rate…

  19. Journal Article Full text

    Versatile clinical movement analysis using statistical parametric mapping in MovementRx

    Alhossary, Amr; Pataky, Todd; Ang, Wei Tech et al.

    Sci Rep · 2023 · English · PubMed Central

    Clinical gait analysis is an important biomechanics field that is often influenced by subjectivity in time-varying analysis leading to type I and II errors. Statistical Parametric Mapping can operate on all time-varying joint dynamics simultaneously, thereby overcoming subjectivity errors. We…