Biblio Discovery — Demo Discovery Service

56 results for "Augat, Peter"

Showing 1–20 · 0.33 seconds · RSS

  1. Journal Article Full text

    Load distribution between cephalic screws in a dual lag screw trochanteric nail

    Henschel, Julia; Eberle, Sebastian; Augat, Peter

    J Orthop Surg Res · 2016 · English · PubMed Central

    BACKGROUND: It has been observed clinically that the Z-effect is a potential cause of failure of an intramedullary nail with two cephalic screws. It describes the migration behavior of the cephalic screws in the femoral head. The primary objective was to examine different cephalic screw…

  2. Journal Article Full text

    Unicortical self-drilling external fixator pins reduce thermal effects during pin insertion

    Greinwald, Markus; Varady, Patrick A.; Augat, Peter

    Eur J Trauma Emerg Surg · 2017 · English · PubMed Central

    INTRODUCTION: External fixation is associated with the risk of pin loosening and pin infection potentially associated to thermal bone necrosis during pin insertion. OBJECTIVE: This study aims to investigate if the use of external fixator systems with unicortical pins reduces the heat production…

  3. Journal Article Full text

    Implant Material and Design Alter Construct Stiffness in Distal Femur Locking Plate Fixation: A Pilot Study

    Schmidt, Ulf; Penzkofer, Rainer; Bachmaier, Samuel et al.

    Clin Orthop Relat Res · 2013 · English · PubMed Central

    BACKGROUND: Construct stiffness affects healing of bones fixed with locking plates. However, variable construct stiffness reported in the literature may be attributable to differing test configurations and direct comparisons may clarify these differences. QUESTIONS/PURPOSES: We therefore asked…

  4. Journal Article Full text

    Influence of total knee arthroplasty on patellar kinematics and contact characteristics

    Kainz, Hans; Reng, Wolfgang; Augat, Peter et al.

    Int Orthop · 2011 · English · PubMed Central

    PURPOSE: Femoro-patellar complications are one of the most common problems after total knee arthroplasty (TKA). TKA components that reduce patellar loads and preserve physiological patellar kinematics should reduce these problems. Therefore, we evaluated the patellar kinematics and the…

  5. Journal Article Full text

    The effect of coronal splits on the structural stability of bi-condylar tibial plateau fractures: a biomechanical investigation

    Samsami, Shabnam; Pätzold, Robert; Winkler, Martin et al.

    Arch Orthop Trauma Surg · 2020 · English · PubMed Central

    INTRODUCTION: Surgical treatment of bi-condylar tibial plateau fractures is still challenging due to the complexity of the fracture and the difficult surgical approach. Coronal fracture lines are associated with a high risk of fixation failure. However, previous biomechanical studies and fracture…

  6. Journal Article Full text

    Impact of lateral cortical notching on biomechanical performance in cephalomedullary nailing for unstable pertrochanteric fractures

    Sandriesser, Sabrina; Ganser, Niels; Hollensteiner, Marianne et al.

    Eur J Trauma Emerg Surg · 2024 · English · PubMed Central

    PURPOSE: In pertrochanteric femur fractures the risk for fracture healing complications increases with the complexity of the fracture. In addition to dynamization along the lag screw, successful fracture healing may also be facilitated by further dynamization along the shaft axis. The aim of this…

  7. Journal Article Full text

    Evaluation of Meniscal Load and Load Distribution in the Sound Canine Stifle at Different Angles of Flexion

    Schmutterer, Johannes Maximilian; Augat, Peter; Greinwald, Markus et al.

    Vet Comp Orthop Traumatol · 2024 · English · PubMed Central

    Objectives The aim of the study was to investigate the contact mechanics and kinematic changes in the stifle in different standing angles. Study Design We performed a biomechanical ex vivo study using pairs of canine cadaver hindlimbs. Motion sensors were fixed to the tibia and the femur for…

  8. Journal Article Full text

    Bewegungsanalyse bei Querschnittverletzungen

    Kröger, Inga; Wackerle, Hannes; Maier, Doris et al.

    Orthopadie (Heidelb) · 2023 · German · PubMed Central

    For motor incomplete spinal cord injured patients, improvement of walking function is an important aim in the rehabilitation program. In specialized treatment centers, the 6‑minute walking test, the 10-meter walking test or the timed-up-and-go test are used as an assessment tool to determine…

  9. Journal Article Full text

    Type of Hip Fracture Determines Load Share in Intramedullary Osteosynthesis

    Eberle, Sebastian; Gerber, Claus; von Oldenburg, Geert et al.

    Clin Orthop Relat Res · 2009 · English · PubMed Central

    The choice of the appropriate implant continues to be critical for fixation of unstable hip fractures. Therefore, the goal of this study was to develop a numerical model to investigate the mechanical performance of hip fracture osteosynthesis. We hypothesized that decreasing fracture stability…

  10. Journal Article Full text

    Biomechanics of Osteoporotic Fracture Fixation

    Hollensteiner, Marianne; Sandriesser, Sabrina; Bliven, Emily et al.

    Curr Osteoporos Rep · 2019 · English · PubMed Central

    PURPOSE OF REVIEW: Fractures of osteoporotic bone in elderly individuals need special attention. This manuscript reviews the current strategies to provide sufficient fracture fixation stability with a particular focus on fractures that frequently occur in elderly individuals with osteoporosis and…

  11. Journal Article Full text

    Cerclage Wiring Improves Biomechanical Stability in Distal Tibia Spiral Fractures Treated by Intramedullary Nailing

    Förch, Stefan; Sandriesser, Sabrina; von Rüden, Christian et al.

    J Clin Med · 2023 · English · PubMed Central

    Background: Partial weight-bearing after operatively treated fractures has been the standard of care over the past decades. Recent studies report on better rehabilitation and faster return to daily life in case of immediate weight-bearing as tolerated. To allow early weight-bearing, osteosynthesis…

  12. Journal Article Full text

    Does minimally invasive external fixation of proximal humerus fractures provide adequate stability? A biomechanical in vitro study

    Greinwald, Markus; Matschl, Franz; Regenbogen, Stephan et al.

    BMC Musculoskelet Disord · 2024 · English · PubMed Central

    INTRODUCTION: Proximal humerus fractures are usually treated with rigid angle-stable plates or nails. As an alternative, semi-rigid, minimally invasive systems have been developed for supportive fixation. A new system uses this principle with 2.5 mm partially threaded pins and external fixation…

  13. Journal Article Full text

    Risk of Interprosthetic Femur Fracture Is Associated with Implant Spacing—A Biomechanical Study

    Mühling, Mischa; Sandriesser, Sabrina; Glowalla, Claudio et al.

    J Clin Med · 2023 · English · PubMed Central

    Background: Ipsilateral revision surgeries of total hip or knee arthroplasties due to periprosthetic fractures or implant loosening are becoming more frequent in aging populations. Implants in revision arthroplasty usually require long anchoring stems. Depending on the residual distance between two…

  14. Journal Article Full text

    Supplemental cerclage wiring in angle stable plate fixation of distal tibial spiral fractures enables immediate post-operative full weight-bearing: a biomechanical analysis

    Sandriesser, Sabrina; Förch, Stefan; Mayr, Edgar et al.

    Eur J Trauma Emerg Surg · 2020 · English · PubMed Central

    PURPOSE: Distal tibial fractures generally require post-operative weight-bearing restrictions. Especially geriatric patients are unable to follow these recommendations. To increase post-operative implant stability and enable early weight-bearing, augmentation of the primary osteosynthesis by…

  15. Journal Article Full text

    Early biomechanical outcome in patients with acetabular fractures treated using the pararectus approach: a gait and stair climb analysis study

    Brand, Andreas; von Rüden, Christian; Probst, Carina et al.

    Eur J Trauma Emerg Surg · 2021 · English · PubMed Central

    PURPOSE: Patients with surgically treated acetabular fractures using extensive dissection of hip muscles demonstrate an incomplete biomechanical recovery and limited joint mobility during movement. The purpose of this study was to evaluate the early biomechanical outcome in a series of patients…

  16. Journal Article Full text

    German translation of the Characterizing Freezing of gait questionnaire: implementation of the TRAPD process

    Wilhelm, Agnes; Janssen, Jessie; Teufelhart, Malena et al.

    J Patient Rep Outcomes · 2025 · English · PubMed Central

    BACKGROUND: Freezing of Gait (FOG) is a severe symptom of Parkinson’s Disease (PD) that affects mobility and quality of life. The ‘Characterizing Freezing of Gait Questionnaire’ (C-FOG) is an assessment tool for screening and determining subtypes of FOG. However, it currently only exists in the…

  17. Journal Article Full text

    Effectiveness of robot-assisted training added to conventional rehabilitation in patients with humeral fracture early after surgical treatment: protocol of a randomised, controlled, multicentre trial

    Nerz, Corinna; Schwickert, Lars; Becker, Clemens et al.

    Trials · 2017 · English · PubMed Central

    BACKGROUND: The incidence of proximal humeral fractures increases with age. The functional recovery of the upper arm after such fractures is slow, and results are often disappointing. Treatment is associated with long immobilisation periods. Evidence-based exercise guidelines are missing. Loss of…

  18. Journal Article Full text

    Single or Double Plating for Acromial Type III Fractures: Biomechanical Comparison of Load to Failure and Fragment Motion

    Hollensteiner, Marianne; Sandriesser, Sabrina; Rittenschober, Felix et al.

    J Clin Med · 2022 · English · PubMed Central

    Background: Acromial Levy III fractures after inverse shoulder arthroplasty occur in up to 7% of patients. To date, it is not clear how these fractures should be treated as clinical outcomes remain unsatisfactory. The aim of this study was to evaluate the biomechanical performance of three…

  19. Journal Article Full text

    The Neutral Hinge for Medial Closing Wedge Distal Femur Osteotomy. A 3-dimensional Surgical Simulation Study

    Watrinet, Julius; Rupp, Marco; Blum, Philipp et al.

    Orthop J Sports Med · 2025 · English · PubMed Central

    BACKGROUND: Because a valgus deformity is frequently associated with patellar instability, medial closed wedge distal femoral osteotomy (MCWDFO) has gained popularity. While the influence of MCWDFO on the leg axis in the coronal plane is widely understood, information is relatively scarce on…

  20. Journal Article Full text

    Biomechanical evaluation of cerclage wiring in plated tibia fractures using human and synthetic specimens

    Sandriesser, Sabrina; Förch, Stefan; Reuter, Jan et al.

    Eur J Trauma Emerg Surg · 2025 · English · PubMed Central

    PURPOSE: Supplemental cerclage wiring at the distal tibia has shown to improve the mechanical stabilization of the fracture. However, its clinical use remains controversial partly because of concerns about implant loosening as well as frictional or constrictive interference between the cerclage and…