9 hasil untuk "Bester, Christofer"
Menampilkan 1–9 · 0,59 detik · RSS
-
Artikel Jurnal Teks lengkap
Characteristics of the Summating Potential Measured Across a Cochlear Implant Array as an Indicator of Cochlear Function
OBJECTIVES: The underlying state of cochlear and neural tissue function is known to affect postoperative speech perception following cochlear implantation. The ability to assess these tissues in patients can be performed using intracochlear electrocochleography (IC ECochG). One component of ECochG…
-
Artikel Jurnal Teks lengkap
Automatic analysis of cochlear response using electrocochleography signals during cochlear implant surgery
Cochlear implants (CIs) provide an opportunity for the hearing impaired to perceive sound through electrical stimulation of the hearing (cochlear) nerve. However, there is a high risk of losing a patient’s natural hearing during CI surgery, which has been shown to reduce speech perception in noisy…
-
Artikel Jurnal Teks lengkap
Characterizing Electrocochleography in Cochlear Implant Recipients with Residual Low-Frequency Hearing
Objective: Lay the groundwork for using electrocochleography (ECochG) as a measure of cochlear health, by characterizing typical patterns of the ECochG response observed across the electrode array in cochlear implant recipients with residual hearing. Methods: ECochG was measured immediately after…
-
Artikel Jurnal Teks lengkap
The effect of surgical complexity on hearing preservation during cochlear implantation with sheathed perimodiolar electrodes
PURPOSE: The causes of residual hearing loss during cochlear implantation are generally poorly understood. This study sought to understand whether the complexity of this surgical approach related to a loss of residual hearing. METHOD: Thirty-four adults underwent implantation with a sheathed…
-
Artikel Jurnal Teks lengkap
Amplitude and Phase Changes in Electrocochleographic Real-Time Recordings During Cochlear Implantation and Its Relation to Pre- and Postoperative Hearing
BACKGROUND: The aim of this study was to relate response patterns of electrocochleography (ECochG) recordings during cochlear implantation to pre- and postoperative hearing. METHODS: Thirty subjects with either flat (FA, n = 9) or sloping (SA, n = 21) audiograms before cochlear implantation were…
-
Artikel Jurnal Teks lengkap
Speech-in-noise performance in objectively determined cochlear implant maps, including the effect of cognitive state
OBJECTIVE: Cochlear Implant (CI) programming based on subjective psychophysical fine-tuning of loudness scaling involves active participation and cognitive skills and thus may not be appropriate for difficult-to-condition populations. The electrically evoked stapedial reflex threshold (eSRT) is an…
-
Preprint Teks lengkap
Time-Transformer: Integrating Local and Global Features for Better Time Series Generation (Extended Version)
Generating time series data is a promising approach to address data deficiency problems. However, it is also challenging due to the complex temporal properties of time series data, including local correlations as well as global dependencies. Most existing generative models have failed to…
-
Artikel Jurnal Teks lengkap
Four-point impedance as a biomarker for bleeding during cochlear implantation
Cochlear implantation has successfully restored the perception of hearing for nearly 200 thousand profoundly deaf adults and children. More recently, implant candidature has expanded to include those with considerable natural hearing which, when preserved, provides an improved hearing experience in…
-
Artikel Jurnal Teks lengkap
Electrocochleography for Monitoring Hearing Preservation During Cochlear Implantation
IMPORTANCE: Many cochlear implant candidates retain residual hearing, which can improve speech perception and overall outcomes. However, residual hearing is frequently lost during implantation. Intraoperative electrocochleography may enable monitoring of residual hearing, but its clinical relevance…