16 hasil untuk "Burke, Martin C."
Menampilkan 1–16 · 1,95 detik · RSS
-
Artikel Jurnal Teks lengkap
Basal cell carcinoma overlying a pacemaker pocket in a pacemaker-dependent patient: Management and course
-
Artikel Jurnal Teks lengkap
QRS complex fragmentation and survival following left ventricular assist device implantation
BACKGROUND: In patients with heart disease, the presence of a fragmented QRS complex (fQRS) on the surface electrocardiogram (ECG) is associated with an increased risk of mortality. We sought to evaluate the prevalence and location of fQRS before and after left ventricular assist device (LVAD)…
-
Artikel Jurnal Teks lengkap
Evaluation of a second-generation intercostal extravascular implantable cardioverter defibrillator lead with a pectoral pulse generator for sensing, defibrillation, and anti-tachycardia pacing
AIMS: Intercostal extravascular implantable cardioverter defibrillator (EV-ICD) leads may work better in contact with the pericardium thereby directing pacing and defibrillation energy towards excitable myocytes. We report 3-month safety and performance outcomes with a second-generation intercostal…
-
Artikel Jurnal Teks lengkap
Successful external cardioversion of atrial fibrillation in patients referred to an electrophysiologist for internal cardioversion
Background: Internal cardioversion of atrial fibrillation with direct current energy has become an increasingly employed technique for patients who fail external cardioversion. Hypothesis: The purpose of this study was to determine whether internal cardioversion could be avoided by careful…
-
Artikel Jurnal Teks lengkap
Influence of late gadolinium enhancement on left ventricular morphology and function in patients with sarcoidosis
Juga tersedia di: PubMed Central
-
Artikel Jurnal Teks lengkap
Impact of Implantable Transvenous Device Lead Location on Severity of Tricuspid Regurgitation
BACKGROUND: Implantable device leads can cause tricuspid regurgitation (TR) when they interfere with leaflet motion. The aim of this study was to determine whether lead-leaflet interference is associated with TR severity, independent of other causative factors of functional TR. METHODS: A total of…
-
Artikel Jurnal Teks lengkap
Myocardial damage in patients with sarcoidosis and preserved left ventricular systolic function: an observational study
AIMS: Late gadolinium enhanced cardiovascular magnetic resonance (LGE‐CMR) is a valuable test to detect myocardial damage in patients with sarcoidosis; however, the clinical significance of LGE in sarcoidosis patients with preserved left ventricular ejection fraction (LVEF) is not defined. We aim…
-
Artikel Jurnal Teks lengkap
The learning curve associated with the introduction of the subcutaneous implantable defibrillator
AIMS: The subcutaneous implantable cardioverter defibrillator (S-ICD) was introduced to overcome complications related to transvenous leads. Adoption of the S-ICD requires implanters to learn a new implantation technique. The aim of this study was to assess the learning curve for S-ICD implanters…
-
Artikel Jurnal Teks lengkap
Primary Results From the Understanding Outcomes With the S-ICD in Primary Prevention Patients With Low Ejection Fraction (UNTOUCHED) Trial
BACKGROUND: The subcutaneous (S) implantable cardioverter-defibrillator (ICD) is safe and effective for sudden cardiac death prevention. However, patients in previous S-ICD studies had fewer comorbidities, had less left ventricular dysfunction, and received more inappropriate shocks (IAS) than in…
-
Artikel Jurnal Teks lengkap
Design and rationale of the MODULAR ATP global clinical trial: A novel intercommunicative leadless pacing system and the subcutaneous implantable cardioverter-defibrillator
BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) has demonstrated safety and efficacy for the treatment of malignant ventricular arrhythmias. However, a limitation of the S-ICD lies in the inability to either pace-terminate ventricular tachycardia or provide prolonged…
-
Artikel Jurnal Teks lengkap
One-Year Outcomes of the MODULAR ATP Trial: A Novel Leadless Pacemaker in Wireless Communication With a Subcutaneous Implantable Cardioverter Defibrillator
BACKGROUND: MODULAR antitachycardia pacing (ATP), a multicenter, international trial, assesses a modular cardiac rhythm management system: a subcutaneous implantable cardioverter defibrillator in wireless communication with a leadless pacemaker (LP) capable of pace-terminating ventricular…
-
Artikel Jurnal Teks lengkap
Pain after subcutaneous implantable cardioverter-defibrillator implantation: A secondary analysis of the PRAETORIAN-DFT trial
BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) overcomes transvenous lead-related complications. Its extrathoracic design results in a generator twice the size of transvenous ICDs. OBJECTIVE: We investigated pain after S-ICD implantation and explore predictors for…
-
Artikel Jurnal Teks lengkap
Device-Related Complications in Transvenous Versus Subcutaneous Defibrillator Therapy During Long-Term Follow-Up: The PRAETORIAN-XL Trial
BACKGROUND: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) investigated the efficacy and safety of the subcutaneous implantable cardioverter defibrillator (S-ICD) compared with a transvenous ICD (TV-ICD) and…
-
Artikel Jurnal Teks lengkap
Quality of Life in Subcutaneous or Transvenous Implantable Cardioverter-Defibrillator Patients: A Secondary Analysis of the PRAETORIAN Trial
BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) was developed to overcome the risk of lead-related complications associated with the transvenous implantable cardioverter-defibrillator (TV-ICD). In contrast to the TV-ICD, the S-ICD is a completely extrathoracic device…
-
Artikel Jurnal Teks lengkap
Device-related complications in subcutaneous versus transvenous ICD: a secondary analysis of the PRAETORIAN trial
BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is developed to overcome lead-related complications and systemic infections, inherent to transvenous ICD (TV-ICD) therapy. The PRAETORIAN trial demonstrated that the S-ICD is non-inferior to the TV-ICD with regard to the…