60 hasil untuk "Contini, Davide"
Menampilkan 1–20 · 0,19 detik · RSS
-
Artikel Jurnal Teks lengkap
Method for the discrimination of superficial and deep absorption variations by time domain fNIRS
A method for the discrimination of superficial and deep absorption variations by time domain functional near infrared spectroscopy is presented. The method exploits the estimate of the photon time-dependent pathlength in different domains of the sampled medium and makes use of an approach based on…
-
Artikel Jurnal Teks lengkap
Effect of a thin superficial layer on the estimate of hemodynamic changes in a two-layer medium by time domain NIRS
In order to study hemodynamic changes involved in muscular metabolism by means of time domain fNIRS, we need to discriminate in the measured signal contributions coming from different depths. Muscles are, in fact, typically located under other tissues, e.g. skin and fat. In this paper, we study the…
-
Artikel Jurnal Teks lengkap
Time Domain Near Infrared Spectroscopy Device for Monitoring Muscle Oxidative Metabolism: Custom Probe and In Vivo Applications
Measurement of muscle oxidative metabolism is of interest for monitoring the training status in athletes and the rehabilitation process in patients. Time domain near infrared spectroscopy (TD NIRS) is an optical technique that allows the non-invasive measurement of the hemodynamic parameters in…
-
Artikel Jurnal Teks lengkap
Depth-selective data analysis for time-domain fNIRS: moments vs. time windows
Time-domain measurements facilitate the elimination of the influence of extracerebral, systemic effects, a key problem in functional near-infrared spectroscopy (fNIRS) of the adult human brain. The analysis of measured time-of-flight distributions of photons often relies on moments or time windows…
-
Artikel Jurnal Teks lengkap
Instrument response function acquisition in reflectance geometry for time-resolved diffuse optical measurements
In time-domain diffuse optical spectroscopy, the simultaneous acquisition of the time-of-flight distribution (DTOF) of photons traveling in a diffusive medium and of the instrument response function (IRF) is necessary to perform quantitative measurements of optical properties (absorption and…
-
Artikel Jurnal Teks lengkap
Fast Multi-Distance Time-Domain NIRS and DCS System for Clinical Applications
We have designed and built an improved system for combined Time-Domain Near-Infrared Spectroscopy (TD NIRS) and Diffuse Correlation Spectroscopy (DCS) measurements. The system features two independent channels, enabling TD NIRS and DCS acquisition at short and long source-detector distances to…
-
Artikel Jurnal Teks lengkap
Detectability of hemodynamic oscillations in cerebral cortex through functional near-infrared spectroscopy: a simulation study
SIGNIFICANCE: We explore the feasibility of using time-domain (TD) and continuous-wave (CW) functional near-infrared spectroscopy (fNIRS) to monitor brain hemodynamic oscillations during resting-state activity in humans, a phenomenon that is of increasing interest in the scientific and medical…
-
Artikel Jurnal Teks lengkap
Probe-hosted silicon photomultipliers for time-domain functional near-infrared spectroscopy: phantom and in vivo tests
We report the development of a compact probe for time-domain (TD) functional near-infrared spectroscopy (fNIRS) based on a fast silicon photomultiplier (SiPM) that can be put directly in contact with the sample without the need of optical fibers for light collection. We directly integrated an…
-
Artikel Jurnal Teks lengkap
Cerebral time domain-NIRS: reproducibility analysis, optical properties, hemoglobin species and tissue oxygen saturation in a cohort of adult subjects
The reproducibility of cerebral time-domain near-infrared spectroscopy (TD-NIRS) has not been investigated so far. Besides, reference intervals of cerebral optical properties, of absolute concentrations of deoxygenated-hemoglobin (HbR), oxygenated-hemoglobin (HbO), total hemoglobin (HbT) and tissue…
-
Artikel Jurnal Teks lengkap
Effect of adipose tissue thickness and tissue optical properties on the differential pathlength factor estimation for NIRS studies on human skeletal muscle
We propose a quantitative and systematic investigation of the differential pathlength factor (DPF) behavior for skeletal muscles and its dependence on different factors, such as the subcutaneous adipose tissue thickness (ATT), the variations of the tissue absorption (µ(a)) and reduced scattering…
-
Artikel Jurnal Teks lengkap
A Compact Multi-Distance DCS and Time Domain NIRS Hybrid System for Hemodynamic and Metabolic Measurements
In this work, we present a new multi-distance diffuse correlation spectroscopy (DCS) device integrated with a compact state-of-the-art time domain near infrared spectroscopy (TD-NIRS) device. The hybrid DCS and TD-NIRS system allows to retrieve information on blood flow, tissue oxygenation, and…
-
Artikel Jurnal Teks lengkap
Effects and correctability of pile-up distortion using established figures of merit in time-domain diffuse optics at extreme photon rates
Time-domain diffuse optics (TD-DO) allows one to probe diffusive media with recognized advantages over other working domains but suffers from a poor signal-to-noise ratio (SNR) resulting from the need to build-up the histogram of single-photon arrival times with maximum count rates (CR) of few…
-
Artikel Jurnal Teks lengkap
Robustness of tissue oxygenation estimates by continuous wave space-resolved near infrared spectroscopy
SIGNIFICANCE: Continuous wave near infrared spectroscopy (CW-NIRS) is widely exploited in clinics to estimate skeletal muscles and brain cortex oxygenation. Spatially resolved spectroscopy (SRS) is generally implemented in commercial devices. However, SRS suffers from two main limitations: the a…
-
Artikel Jurnal Teks lengkap
Accuracy of homogeneous models for photon diffusion in estimating neonatal cerebral hemodynamics by TD-NIRS
We assessed the accuracy of homogenous (semi-infinite, spherical) photon diffusion models in estimating absolute hemodynamic parameters of the neonatal brain in realistic scenarios (ischemia, hyperoxygenation, and hypoventilation) from 1.5 cm interfiber distance TD NIRS measurements…
-
Artikel Jurnal Teks lengkap
Multi-channel medical device for time domain functional near infrared spectroscopy based on wavelength space multiplexing
We have designed a compact dual wavelength (687 nm, 826 nm) multi-channel (16 sources, 8 detectors) medical device for muscle and brain imaging based on time domain functional near infrared spectroscopy. The system employs the wavelength space multiplexing approach to reduce wavelength cross-talk…
-
Artikel Jurnal Teks lengkap
Self-calibrating time-resolved near infrared spectroscopy
Time-resolved near infrared spectroscopy is considered to be a gold standard technique when measuring absolute values of tissue optical properties, as it provides separable and independent information about both tissue absorption and scattering. However, time-resolved instruments require an…
-
Artikel Jurnal Teks lengkap
Time-domain near-infrared spectroscopy in acute ischemic stroke patients
Large vessel occlusion (LVO) stroke might cause different degrees of hemodynamic impairment that affects microcirculation and contributes to metabolic derangement. Time-domain near-infrared spectroscopy (TD-NIRS) estimates the oxygenation of microcirculation of cerebral outer layers. We measure…
-
Artikel Jurnal Teks lengkap
Linear regression models and k-means clustering for statistical analysis of fNIRS data
We propose a new algorithm, based on a linear regression model, to statistically estimate the hemodynamic activations in fNIRS data sets. The main concern guiding the algorithm development was the minimization of assumptions and approximations made on the data set for the application of statistical…
-
Artikel Jurnal Teks lengkap
Optical characterization of 3D printed PLA and ABS filaments for diffuse optics applications
The interest for Fused Deposition Modelling (FDM) in the field of Diffuse Optics (DO) is rapidly increasing. The most widespread FDM materials are polylactic acid (PLA) and acrylonitrile butadiene styrene (ABS), thanks to their low cost and easiness-to-print. This is why, in this study, 3D printed…