23 hasil untuk "Dalbert, Adrian"
Menampilkan 1–20 · 0,51 detik · RSS
-
Artikel Jurnal Teks lengkap
Anwendung der extra- und intracochleären Elektrocochleographie während und nach der Cochleaimplantation
Electrocochleography (ECochG) represents a promising approach for monitoring cochlear function during cochlear implantation and for investigating the causes of residual cochlear function loss after implantation. This paper provides an overview of the current research and application status of…
-
Artikel Jurnal Teks lengkap
Radioanatomy of the Silent Sinus Syndrome
OBJECTIVES: Silent sinus syndrome (SSS) arises from negative pressure in the maxillary sinus through occlusion of the ethmoidal infundibulum. Convexity of the surrounding bone towards the lumen and a hypoglobus can occur. It may endanger surrounding structures during endoscopic sinus surgery. This…
-
Artikel Jurnal Teks lengkap
Correlation between Speech Perception Outcomes after Cochlear Implantation and Postoperative Acoustic and Electric Hearing Thresholds
The reliable prediction of cochlear implant (CI) speech perception outcomes is highly relevant and can facilitate the monitoring of postoperative hearing performance. To date, multiple audiometric, demographic, and surgical variables have shown some degree of correlation with CI speech perception…
-
Artikel Jurnal Teks lengkap
Amplitude and Phase Changes in Electrocochleographic Real-Time Recordings During Cochlear Implantation and Its Relation to Pre- and Postoperative Hearing
BACKGROUND: The aim of this study was to relate response patterns of electrocochleography (ECochG) recordings during cochlear implantation to pre- and postoperative hearing. METHODS: Thirty subjects with either flat (FA, n = 9) or sloping (SA, n = 21) audiograms before cochlear implantation were…
-
Artikel Jurnal Teks lengkap
Assessment of Cochlear Function during Cochlear Implantation by Extra- and Intracochlear Electrocochleography
Objective: The aims of this study were: (1) To investigate the correlation between electrophysiological changes during cochlear implantation and postoperative hearing loss, and (2) to detect the time points that electrophysiological changes occur during cochlear implantation. Material and Methods…
-
Artikel Jurnal Teks lengkap
Objectification of intracochlear electrocochleography using machine learning
INTRODUCTION: Electrocochleography (ECochG) measures inner ear potentials in response to acoustic stimulation. In patients with cochlear implant (CI), the technique is increasingly used to monitor residual inner ear function. So far, when analyzing ECochG potentials, the visual assessment has been…
-
Artikel Jurnal Teks lengkap
ZH-ECochG Bode Plot: A Novel Approach to Visualize Electrocochleographic Data in Cochlear Implant Users
Background: Various representations exist in the literature to visualize electrocochleography (ECochG) recordings along the basilar membrane (BM). This lack of generalization complicates comparisons within and between cochlear implant (CI) users, as well as between publications. This study…
-
Artikel Jurnal Teks lengkap
Packaging Technology for an Implantable Inner Ear MEMS Microphone
Current cochlear implant (CI) systems provide substantial benefits for patients with severe hearing loss. However, they do not allow for 24/7 hearing, mainly due to the external parts that cannot be worn in all everyday situations. One of the key missing parts for a totally implantable CI (TICI) is…
-
Artikel Jurnal Teks lengkap
The Inter-Phase Gap Offset Effect as a Measure of Neural Health in Cochlear Implant Users With Residual Acoustic Hearing
OBJECTIVES: The inter-phase gap (IPG) offset effect is defined as the dB offset between the linear parts of electrically evoked compound action potential (ECAP) amplitude growth functions for two stimuli differing only in IPG. The method was recently suggested to represent neural health in cochlear…
-
Artikel Jurnal Teks lengkap
Simultaneous Intra- and Extracochlear Electrocochleography During Cochlear Implantation to Enhance Response Interpretation
The use of electrocochleography (ECochG) for providing real-time feedback of cochlear function during cochlear implantation is receiving increased attention for preventing cochlear trauma and preserving residual hearing. Although various studies investigated the relationship between intra-operative…
-
Artikel Jurnal Teks lengkap
An intracochlear electrocochleography dataset - from raw data to objective analysis using deep learning
Electrocochleography (ECochG) measures electrophysiological inner ear potentials in response to acoustic stimulation. These potentials reflect the state of the inner ear and provide important information about its residual function. For cochlear implant (CI) recipients, we can measure ECochG…
-
Artikel Jurnal Teks lengkap
Bilocated Intracochlear Electrocochleography During Cochlear Implantation to Provide Surgical Feedback
INTRODUCTION: Recent advancements toward minimizing surgical trauma and preserving residual hearing during cochlear implantation have promoted the use of intracochlear electrocochleography (ECochG) for intraoperative surveillance. However, variations in the distribution of response generators…
-
Artikel Jurnal Teks lengkap
Calcium sulfate matrix as local antibiotic carrier in the mastoid
We describe the use of calcium sulfate beads as antibiotic carrier in a patient, who suffered from chronic mastoiditis with consecutive otogenic meningitis due to Burkholderia cenocepacia. Our findings suggest a possible role of calcium sulfate matrix as a local antibiotic carrier in the mastoid in…
-
Artikel Jurnal Teks lengkap
Radiologically Assessed Stapes Footplate Thickness and Audiologic Outcomes in Patients with Otosclerosis
INTRODUCTION: Otosclerosis is a known cause of particularly conductive hearing loss of a variable extent. Radiological examination reveals footplate thickening in addition to heterogeneously distributed hypodense foci. The objective of this study was to investigate the correlation between a…
-
Artikel Jurnal Teks lengkap
Impact of Cochlear Trauma Degree and Localization on Intracochlear Electrocochleographic Recordings
Background/Objectives: Electrocochleography (ECochG) is a promising tool to monitor preservation of cochlear structures and function during cochlear implant (CI) surgery. However, the interpretation of ECochG signal changes during insertion of the CI electrode array remains controversial. This…
-
Artikel Jurnal Teks lengkap
Normative Values of Brainstem Auditory-Evoked Responses in Sheep
Background: The brainstem auditory-evoked response (BAER) is an established electrophysiological measure of neural activity from the auditory nerve up to the brain stem. The BAER is used to diagnose abnormalities in auditory pathways and in neurophysiological human and animal research. However…
-
Artikel Jurnal Teks lengkap
Evaluating Wideband Tympanometry Absorbance Changes in Cochlear Implant Recipients: Mechanical Insights and Influencing Parameters
Background: Cochlear implant (CI) electrode insertion can change the mechanical state of the ear whereby wideband tympanometry absorbance (WBTA) may serve as a sensitive tool to monitor these mechanical changes of the peripheral auditory pathway after CI surgery. In WBTA, the amount of acoustic…
-
Artikel Jurnal Teks lengkap
Electrocochleography for Monitoring Hearing Preservation During Cochlear Implantation
IMPORTANCE: Many cochlear implant candidates retain residual hearing, which can improve speech perception and overall outcomes. However, residual hearing is frequently lost during implantation. Intraoperative electrocochleography may enable monitoring of residual hearing, but its clinical relevance…
-
Artikel Jurnal Teks lengkap
Vestibular Aqueduct Hypoplasia Identifies Semicircular Canal Dehiscence Patients Who Progress to Meniere’s Disease
OBJECTIVE: Semicircular canal dehiscence (SCD) and vestibular aqueduct (VA) hypoplasia are developmental anomalies associated with distinct inner ear syndromes—SCD syndrome and Meniere’s disease (MD). Our previous work found frequent SCD in MD patients with VA hypoplasia, suggesting a shared…
-
Artikel Jurnal Teks lengkap
Proof of Concept for an Intracochlear Acoustic Receiver for Use in Acute Large Animal Experiments
(1) Background: The measurement of intracochlear sound pressure (ICSP) is relevant to obtain better understanding of the biomechanics of hearing. The goal of this work was a proof of concept of a partially implantable intracochlear acoustic receiver (ICAR) fulfilling all requirements for acute ICSP…