23 hasil untuk "Dave, Jaydev K."
Menampilkan 1–20 · 1,61 detik · RSS
-
Artikel Jurnal Teks lengkap
Shear Wave Elastography Primer for the Abdominal Radiologist
PURPOSE: Shear wave elastography (SWE) provides a means for adding information about the mechanical properties of tissues to a diagnostic ultrasound examination. It is important to understand the physics and methods by which the measurements are made to aid interpretation of the results as they…
-
Artikel Jurnal Teks lengkap
Shear wave elastography of the deltoid muscle in healthy volunteers – quantifying age-dependent normal values
INTRODUCTION: Reverse shoulder arthroplasty (RSA) is performed for various shoulder pathologies. Inadequate tensioning of the deltoid muscle can lead to complications, highlighting the need for optimization. Preoperative quantification of deltoid health may improve operative execution and outcomes…
-
Artikel Jurnal Teks lengkap
Parametric Imaging Using Subharmonic Signals From Ultrasound Contrast Agents in Patients With Breast Lesions
Parametric maps showing perfusion of contrast media can be useful tools for characterizing lesions in breast tissue. In this study we show the feasibility of parametric subharmonic imaging (SHI), which allows imaging of a vascular marker (the ultrasound contrast agent) while providing near complete…
-
Artikel Jurnal Teks lengkap
Recent Technological Advancements in Cardiac Ultrasound Imaging
About 92.1 million Americans suffer from at least one type of cardiovascular disease. Worldwide, cardiovascular diseases are the number one cause of death (about 31% of all global deaths). Recent technological advancements in cardiac ultrasound imaging are expected to aid in the clinical diagnosis…
-
Artikel Jurnal Teks lengkap
Alcoholic vs. Nonalcoholic Steatohepatitis: Vascular Branching Heterogeneity on Magnetic Resonance Imaging as a Diagnostic Marker
BACKGROUND AND AIMS: Distinguishing alcoholic steatohepatitis (ASH) and nonalcoholic steatohepatitis (NASH) with biopsy alone is often difficult without a reliable clinical context. A novel finding on liver imaging, perivascular branching heterogeneity, has shown promise in distinguishing between…
-
Artikel Jurnal Teks lengkap
Estimated size of the clinical medical imaging physics workforce in the United States
There is no current authoritative accounting of the number of clinical imaging physicists practicing in the United States. Information about the workforce is needed to inform future efforts to secure training pathways and opportunities. In this study, the AAPM Diagnostic Demand and Supply…
-
Artikel Jurnal Teks lengkap
SUBHARMONIC CONTRAST MICROBUBBLE SIGNALS FOR NONINVASIVE PRESSURE ESTIMATION UNDER STATIC AND DYNAMIC FLOW CONDITIONS
Our group has proposed the concept of subharmonic aided pressure estimation (SHAPE) utilizing microbubble-based ultrasound contrast agent signals for the noninvasive estimation of hydrostatic blood pressures. An experimental system for in vitro SHAPE was constructed based on two single-element…
-
Artikel Jurnal Teks lengkap
Photon-counting detector CT allows significant reduction in radiation dose while maintaining image quality and noise on non-contrast chest CT
PURPOSE: To investigate if clinical non-contrast chest CT studies obtained with PCD CT using much lower radiation exposure can achieve the same image quality as with the currently established EID protocol. MATERIALS/METHODS: A total of seventy-one patients were identified who had a non-contrast…
-
Artikel Jurnal Teks lengkap
Subharmonic microbubble emissions for noninvasively tracking right ventricular pressures
Right heart catheterization is often required to monitor intra-cardiac pressures in a number of disease states. Ultrasound contrast agents can produce pressure modulated subharmonic emissions that may be used to estimate right ventricular (RV) pressures. A technique based on subharmonic acoustic…
-
Artikel Jurnal Teks lengkap
Noninvasive left ventricular pressure estimation using subharmonic emissions from microbubbles – an in vivo pilot study
The purpose of this study was to develop and investigate a new noninvasive approach to quantify left ventricular (LV) pressures using subharmonic emissions from microbubbles. A Sonix RP ultrasound scanner with PA4-2 phased array transducer was used in pulse inversion grayscale mode. Unprocessed…
-
Artikel Jurnal Teks lengkap
Effect of pulse shaping on subharmonic aided pressure estimation in vitro and in vivo
Subharmonic imaging (SHI) is a technique that uses the nonlinear oscillations of microbubbles when exposed to ultrasound at high pressures transmitting at the fundamental frequency i.e., f(o) and receiving at half the transmit frequency i.e., f(o)/2. Subharmonic aided pressure estimation (SHAPE) is…
-
Artikel Jurnal Teks lengkap
SUBHARMONIC AIDED PRESSURE ESTIMATION FOR MONITORING INTERSTITIAL FLUID PRESSURE IN TUMORS: CALIBRATION AND TREATMENT WITH PACLITAXEL IN BREAST CANCER XENOGRAFTS
This project noninvasively estimated interstitial fluid pressure (IFP) in rats with breast cancer xenografts using subharmonic aided pressure estimation (SHAPE) versus an invasive pressure monitor. Moreover, monitoring of IFP changes after chemotherapy was assessed. Eighty-nine rats (calibration…
-
Artikel Jurnal Teks lengkap
Acute Portal Hypertension Models in Dogs: Low- and High-Flow Approaches
Effective animal models are needed to evaluate the feasibility of new techniques to assess portal hypertension (PH). Here we developed 2 canine models of acute PH by increasing intrasinusoidal resistance and by increasing the portal vein (PV) flow volume to test the efficacy of a noninvasive…
-
Artikel Jurnal Teks lengkap
3D Subharmonic Ultrasound Imaging In Vitro and In Vivo
RATIONALE AND OBJECTIVES: While contrast-enhanced ultrasound imaging techniques such as harmonic imaging (HI) have evolved to reduce tissue signals using the nonlinear properties of the contrast agent, levels of background suppression have been mixed. Subharmonic imaging (SHI) offers near-complete…
-
Artikel Jurnal Teks lengkap
Comparing Central Aortic Pressures Obtained Using a SphygmoCor Device to Pressures Obtained Using a Pressure Catheter
BACKGROUND: This study compared aortic pressures estimated using a SphygmoCor XCEL PWA device (ATCOR, Naperville, IL) noninvasively with aortic pressures obtained using pressure catheters during catheterization procedures and analyzed the impact of a linear-fit function on the estimated pressure…
-
Artikel Jurnal Teks lengkap
Perfusion estimation using contrast enhanced three-dimensional subharmonic ultrasound imaging: an in vivo study
OBJECTIVES: The ability to estimate tissue perfusion (in mL/min/g) in vivo using contrast-enhanced three-dimensional (3D) harmonic and subharmonic ultrasound imaging was investigated. MATERIALS AND METHODS: A Logiq 9 scanner (GE Healthcare, Milwaukee, WI) equipped with a 4D10L probe was modified to…
-
Artikel Jurnal Teks lengkap
Comparing quantitative immunohistochemical markers of angiogenesis to subharmonic contrast imaging
OBJECTIVE: Different methods for obtaining tumor neovascularity parameters based on immunohistochemical markers were compared to contrast-enhanced subharmonic ultrasound imaging (SHI). METHODS: Eighty-five athymic, nude, female rats were implanted with 5×10(6) breast cancer cells (MDA-MB-231) in…
-
Artikel Jurnal Teks lengkap
Evaluation of Intracardiac Pressures Using Subharmonic-aided Pressure Estimation with Sonazoid Microbubbles
PURPOSE: To investigate if the right ventricular (RV) systolic and left ventricular (LV) diastolic pressures can be obtained noninvasively using the subharmonic-aided pressure estimation (SHAPE) technique with Sonazoid microbubbles. MATERIALS AND METHODS: Individuals scheduled for a left and/or…
-
Artikel Jurnal Teks lengkap
High and low frequency subharmonic imaging of angiogenesis in a murine breast cancer model
This project compared quantifiable measures of tumor vascularity obtained from contrast-enhanced high frequency (HF) and low frequency (LF) subharmonic ultrasound imaging (SHI) to 3 immunohistochemical markers of angiogenesis in a murine breast cancer model (since angiogenesis is an important…
-
Artikel Jurnal Teks lengkap
Investigating the efficacy of subharmonic aided pressure estimation for portal vein pressures and portal hypertension monitoring
The efficacy of using subharmonic emissions from Sonazoid microbubbles (GE Healthcare, Oslo, Norway) to track portal vein pressures and pressure changes was investigated in 14 canines using either slow- or high-flow models of portal hypertension (PH). A modified Logiq 9 scanner (GE Healthcare…