Biblio Discovery — Demo Discovery Service

34 hasil untuk "Dehaes, Mathieu"

Menampilkan 1–20 · 0,07 detik · RSS

  1. Artikel Jurnal Teks lengkap

    MCOCT: an experimentally and numerically validated, open-source Monte Carlo simulator for optical coherence tomography

    Erdenedalai, Khaliun; Maltais-Tariant, Raphaël; Dehaes, Mathieu dkk.

    Biomed Opt Express · 2024 · Inggris · PubMed Central

    Here, we present MCOCT, a Monte Carlo simulator for optical coherence tomography (OCT), incorporating a Gaussian illumination scheme and bias to increase backscattered event collection. MCOCT optical fluence was numerically compared and validated to an established simulator (MCX) and showed…

  2. Artikel Jurnal Teks lengkap

    Multifocal optical coherence tomography of the mouse eye to image the vitreoretinal vasculature in full depth

    Brais-Brunet, Simon; Maltais-Tariant, Raphaël; Boudoux, Caroline dkk.

    J Biomed Opt · 2025 · Inggris · PubMed Central

    SIGNIFICANCE: In vivo optical coherence tomography (OCT) of the mouse vitreoretinal vasculature in full depth is technically challenging. Conventional OCT techniques employ axial confocal gating, which induces signal drop-off and limits spatial resolution outside the Rayleigh range. AIM: Our aim is…

  3. Artikel Jurnal Teks lengkap

    Cerebral oxygen saturation and peripheral perfusion in the extremely premature infant with intraventricular and/or pulmonary haemorrhage early in life

    Beausoleil, Thierry P.; Janaillac, Marie; Barrington, Keith J. dkk.

    Sci Rep · 2018 · Inggris · PubMed Central

    Extremely preterm infants are at higher risk of pulmonary (PH) and intraventricular (IVH) haemorrhage during the transitioning physiology due to immature cardiovascular system. Monitoring of haemodynamics can detect early abnormal circulation that may lead to these complications. We described…

  4. Artikel Jurnal Teks lengkap

    Quantification of extra-cerebral and cerebral hemoglobin concentrations during physical exercise using time-domain near infrared spectroscopy

    Auger, Héloïse; Bherer, Louis; Boucher, Étienne dkk.

    Biomed Opt Express · 2016 · Inggris · PubMed Central

    Fitness is known to have beneficial effects on brain anatomy and function. However, the understanding of mechanisms underlying immediate and long-term neurophysiological changes due to exercise is currently incomplete due to the lack of tools to investigate brain function during physical activity…

  5. Artikel Jurnal Teks lengkap

    Quantitative effect of the neonatal fontanel on synthetic near infrared spectroscopy measurements

    Dehaes, Mathieu; Kazemi, Kamran; Pélégrini‐Issac, Mélanie dkk.

    Hum Brain Mapp · 2011 · Inggris · PubMed Central

    Near infrared spectroscopy (NIRS) is a functional imaging technique allowing measurement of local cerebral oxygenation. This modality is particularly adapted to critically ill neonates, as it can be used at the bedside and is a suitable and noninvasive tool for carrying out longitudinal studies…

  6. Artikel Jurnal Teks lengkap

    Development of a semi-automatic segmentation technique based on mean magnetic resonance imaging intensity thresholding for volumetric quantification of plexiform neurofibromas

    Kiaei, Dorsa Sadat; El-Jalbout, Ramy; Décarie, Jean-Claude dkk.

    Heliyon · 2023 · Inggris · PubMed Central

    RATIONALE AND OBJECTIVES: Plexiform neurofibromas (PNs) are peripheral nerve tumors that occur in 25–50 % of patients with neurofibromatosis type 1. PNs may have complex, diffused, and irregular shapes. The objective of this work was to develop a volumetric quantification method for PNs as clinical…

  7. Artikel Jurnal Teks lengkap

    Speckle contrast reduction through the use of a modally-specific photonic lantern for optical coherence tomography

    Maltais-Tariant, Raphaël; Itzamna Becerra-Deana, Rodrigo; Brais-Brunet, Simon dkk.

    Biomed Opt Express · 2023 · Inggris · PubMed Central

    A few-mode optical coherence tomography (FM-OCT) system was developed around a 2 × 1 modally-specific photonic lantern (MSPL) centered at 1310 nm. The MSPL allowed FM-OCT to acquire two coregistered images with uncorrelated speckle patterns generated by their specific coherent spread function…

  8. Artikel Jurnal Teks lengkap

    Accurate flow speed measurement through correlation ratios using a mode-selective photonic lantern in optical coherence tomography

    Maltais-Tariant, Raphaël; Becerra-Deana, Rodrigo Itzamna; Brais-Brunet, Simon dkk.

    Biomed Opt Express · 2025 · Inggris · PubMed Central

    A novel method for measuring non-axial flow speed using optical techniques such as optical coherence tomography is introduced. The approach was based on the use of a modally-specific photonic lantern, which permits simultaneous probing of the sample with three distinct coherent spread functions…

  9. Artikel Jurnal Teks lengkap

    Regional and Hemispheric Asymmetries of Cerebral Hemodynamic and Oxygen Metabolism in Newborns

    Lin, Pei-Yi; Roche-Labarbe, Nadège; Dehaes, Mathieu dkk.

    Cereb Cortex · 2012 · Inggris · PubMed Central

    Understanding the evolution of regional and hemispheric asymmetries in the early stages of life is essential to the advancement of developmental neuroscience. By using 2 noninvasive optical methods, frequency-domain near-infrared spectroscopy and diffuse correlation spectroscopy, we measured…

  10. Artikel Jurnal Teks lengkap

    RELATIONSHIPS BETWEEN NEAR-INFRARED SPECTROSCOPY, PREDUCTAL PERFUSION INDEX AND CARDIAC OUTPUTS IN EXTREMELY PRETERM INFANTS IN THE FIRST 72 HOURS OF LIFE

    Janaillac, Marie; Beausoleil, Thierry; Karam, Oliver dkk.

    Paediatr Child Health · 2018 · Inggris · PubMed Central

    BACKGROUND: Assessment of hemodynamics during the transitional period in preterm infants is challenging. OBJECTIVES: We aimed to describe the relationship between cerebral regional tissue oxygenation saturation (CrSO(2)), preductal perfusion index (PI), echocardiographic and clinical parameters in…

  11. Artikel Jurnal Teks lengkap

    Morphometric and Microstructural Changes During Murine Retinal Development Characterized Using In Vivo Optical Coherence Tomography

    Brais-Brunet, Simon; Heckel, Émilie; Kanniyappan, Udayakumar dkk.

    Invest Ophthalmol Vis Sci · 2021 · Inggris · PubMed Central

    PURPOSE: The purpose of this study was to develop an in vivo optical coherence tomography (OCT) system capable of imaging the developing mouse retina and its associated morphometric and microstructural changes. METHODS: Thirty-four wild-type mice (129S1/SvlmJ) were anesthetized and imaged between…

  12. Artikel Jurnal Teks lengkap

    All-fiber few-mode optical coherence tomography using a modally-specific photonic lantern

    de Sivry-Houle, Martin Poinsinet; Beaudoin, Simon Bolduc; Brais-Brunet, Simon dkk.

    Biomed Opt Express · 2021 · Inggris · PubMed Central

    Optical coherence tomography (OCT) was recently performed using a few-mode (FM) fiber to increase contrast or improve resolution using a sequential time-domain demultiplexing scheme isolating the different interferometric signals of the mode-coupled backscattered light. Here, we present an…

  13. Artikel Jurnal Teks lengkap

    Near-infrared spectroscopy assessment of cerebral oxygen metabolism in the developing premature brain

    Roche-Labarbe, Nadège; Fenoglio, Angela; Aggarwal, Alpna dkk.

    J Cereb Blood Flow Metab · 2011 · Inggris · PubMed Central

    Little is known about cerebral blood flow, cerebral blood volume (CBV), oxygenation, and oxygen consumption in the premature newborn brain. We combined quantitative frequency-domain near-infrared spectroscopy measures of cerebral hemoglobin oxygenation (SO(2)) and CBV with diffusion correlation…

  14. Artikel Jurnal Teks lengkap

    Design and construction of an optimized transmit/receive hybrid birdcage resonator to improve full body images of medium-sized animals in 7T scanner

    Lopez Rios, Nibardo; Pouliot, Philippe; Papoutsis, Konstantinos dkk.

    PLoS One · 2018 · Inggris · PubMed Central

    The purpose of this work was to develop an optimized transmit/receive birdcage coil to extend the possibilities of a 7T preclinical MRI system to conduct improved full body imaging in medium-sized animals, such as large New Zealand rabbits. The coil was designed by combining calculation and…

  15. Artikel Jurnal Teks lengkap

    Quantitative investigation of the effect of the extra-cerebral vasculature in diffuse optical imaging: a simulation study

    Dehaes, Mathieu; Gagnon, Louis; Lesage, Frédéric dkk.

    Biomed Opt Express · 2011 · Inggris · PubMed Central

    Diffuse optical imaging (DOI) is a non invasive technique allowing the recovery of hemodynamic changes in the brain. Due to the diffusive nature of photon propagation in turbid media and the fact that cerebral tissues are located around 1.5 cm under the adult human scalp, DOI measurements are…

  16. Artikel Jurnal Teks lengkap

    Assessment of the frequency-domain multi-distance method to evaluate the brain optical properties: Monte Carlo simulations from neonate to adult

    Dehaes, Mathieu; Grant, P. Ellen; Sliva, Danielle D. dkk.

    Biomed Opt Express · 2011 · Inggris · PubMed Central

    The near infrared spectroscopy (NIRS) frequency-domain multi-distance (FD-MD) method allows for the estimation of optical properties in biological tissue using the phase and intensity of radiofrequency modulated light at different source-detector separations. In this study, we evaluated the…

  17. Artikel Jurnal Teks lengkap

    Non-invasive Optical Measurement of Cerebral Metabolism and Hemodynamics in Infants

    Lin, Pei-Yi; Roche-Labarbe, Nadege; Dehaes, Mathieu dkk.

    J Vis Exp · 2013 · Inggris · PubMed Central

    Perinatal brain injury remains a significant cause of infant mortality and morbidity, but there is not yet an effective bedside tool that can accurately screen for brain injury, monitor injury evolution, or assess response to therapy. The energy used by neurons is derived largely from tissue…

  18. Artikel Jurnal Teks lengkap

    Electroencephalography and optical neuromonitoring predict short-term outcomes in neonates undergoing therapeutic hypothermia for hypoxic-ischemic encephalopathy

    Chowdhury, Rasheda Arman; Mahdi, Zamzam; Desnous, Beatrice dkk.

    Sci Rep · 2025 · Inggris · PubMed Central

    Electroencephalography (EEG) and optical neuromonitoring were used to predict short-term outcomes in neonates undergoing therapeutic hypothermia (TH) for hypoxic-ischemic encephalopathy (HIE). Fifty-two neonates undergoing TH for HIE were prospectively recruited. Continuous EEG monitoring was…

  19. Artikel Jurnal Teks lengkap

    Cerebral oxygen metabolism in neonatal hypoxic ischemic encephalopathy during and after therapeutic hypothermia

    Dehaes, Mathieu; Aggarwal, Alpna; Lin, Pei-Yi dkk.

    J Cereb Blood Flow Metab · 2013 · Inggris · PubMed Central

    Pathophysiologic mechanisms involved in neonatal hypoxic ischemic encephalopathy (HIE) are associated with complex changes of blood flow and metabolism. Therapeutic hypothermia (TH) is effective in reducing the extent of brain injury, but it remains uncertain how TH affects cerebral blood flow…