Biblio Discovery — Demo Discovery Service

72 results for "Desai, Jaydev P."

Showing 1–20 · 0.27 seconds · RSS

  1. Journal Article Full text

    Pulse width modulation-based temperature tracking for feedback control of a shape memory alloy actuator

    Ayvali, Elif; Desai, Jaydev P.

    J Intell Mater Syst Struct · 2013 · English · PubMed Central

    This work presents a temperature-feedback approach to control the radius of curvature of an arc-shaped shape memory alloy (SMA) wire. The nonlinear properties of the SMA such as phase transformation and its dependence on temperature and stress make SMA actuators difficult to control. Tracking a…

  2. Journal Article Full text

    Estimating zero strain states of very soft tissue under gravity loading using digital image correlation,,

    Gao, Zhan; Desai, Jaydev P.

    Med Image Anal · 2009 · English · PubMed Central

    This paper presents several experimental techniques and concepts in the process of measuring mechanical properties of very soft tissue in an ex vivo tensile test. Gravitational body force on very soft tissue causes pre-compression and results in a non-uniform initial deformation. The global Digital…

  3. Journal Article Full text

    Development of a Meso-Scale Fiberoptic Rotation Sensor for a Torsion Actuator

    Sheng, Jun; Desai, Jaydev P.

    IEEE Robot Autom Lett · 2017 · English · PubMed Central

    This paper presents the development of a meso-scale fiberoptic rotation sensor for a shape memory alloy (SMA) torsion actuator for neurosurgical applications. Within the sensor, a rotary head with a reflecting surface is capable of modulating the light intensity collected by optical fibers when the…

  4. Journal Article Full text

    Micropositioning and Control of an Underactuated Platform for Microscopic Applications

    Park, Kihan; Desai, Jaydev P.

    IEEE ASME Trans Mechatron · 2016 · English · PubMed Central

    For automation of biological experiments at the micro-scale, highly precise manipulator equipped with a microscope is required. However, current micropositioning stages have several limitations, such as: 1) manual operation, 2) lack of rotational capability, 3) incompatibility with a microscope…

  5. Journal Article Full text

    Determination of Mechanical Properties of Spatially Heterogeneous Breast Tissue Specimens Using Contact Mode Atomic Force Microscopy (AFM)

    Roy, Rajarshi; Desai, Jaydev P.

    Ann Biomed Eng · 2014 · English · PubMed Central

    This paper outlines a comprehensive parametric approach for quantifying mechanical properties of spatially heterogeneous thin biological specimens such as human breast tissue using contact-mode Atomic Force Microscopy. Using inverse finite element (FE) analysis of spherical nanoindentation, the…

  6. Journal Article Full text

    Optical Flow-Based Tracking of Needles and Needle-Tip Localization Using Circular Hough Transform in Ultrasound Images

    Ayvali, Elif; Desai, Jaydev P.

    Ann Biomed Eng · 2014 · English · PubMed Central

    Image-guided interventions have become the standard of care for needle-based procedures. The success of the image-guided procedures depends on the ability to precisely locate and track the needle. This work is primarily focused on 2D ultrasound-based tracking of a hollow needle (cannula) that is…

  7. Journal Article Full text

    Design, Modeling and Characterization of A Novel Meso-Scale SMA-Actuated Torsion Actuator

    Sheng, Jun; Desai, Jaydev P.

    Smart Mater Struct · 2015 · English · PubMed Central

    This paper presents our work on design, modeling and characterization of a novel shape memory alloy (SMA) actuated torsion actuator for meso-scale robots. Development of a miniature torsion actuator is challenging, but it can enhance the agility and enlarge the workspace of meso-scale robots. This…

  8. Journal Article Full text

    Towards a Tendon-Driven Robotically Steerable Guidewire with a Retractable Distal Balloon

    Barré, C. Cloud; Desai, Jaydev P.

    IEEE Robot Autom Lett · 2025 · English · PubMed Central

    Minimally invasive endovascular and transcather procedures frequently involve delivering tools to the surgical site via a guidewire. Even when made steerable, the guidewire tip has the potential to cause tissue damage while traversing the vasculature and the connected organs. In this work, a…

  9. Journal Article Full text

    Modeling Non-linear Effects in a 4-DoF Robotic Transcatheter Delivery System

    Nayar, Namrata U.; Desai, Jaydev P.

    IEEE Robot Autom Lett · 2024 · English · PubMed Central

    Transcatheter mitral valve repair (TMVr), a minimally invasive approach, is becoming increasingly popular for treating mitral regurgitation (MR) since nearly half of the MR patients are non-surgical candidates. However, current TMVr devices are operated manually, increasing radiation exposure to…

  10. Journal Article Full text

    Ultrasound-Guided Real-Time Joint Space Control of a Robotic Transcatheter Delivery System

    Nayar, Namrata U.; Desai, Jaydev P.

    IEEE Robot Autom Lett · 2024 · English · PubMed Central

    Transcatheter mitral valve repair (TMVr) is growing in popularity for non-surgical mitral regurgitation (MR) patients, but the manual operation of current TMVr devices increases radiation exposure and limits telesurgery feasibility. A robotically steerable delivery system can alleviate these…

  11. Journal Article Full text

    Development of in vivo Constitutive Models for Liver: Application to Surgical Simulation

    Lister, Kevin; Gao, Zhan; Desai, Jaydev P.

    Ann Biomed Eng · 2010 · English · PubMed Central

    Advancements in real-time surgical simulation techniques have provided the ability to utilize more complex nonlinear constitutive models for biological tissues which result in increased haptic and graphic accuracy. When developing such a model, verification is necessary to determine the accuracy of…

  12. Journal Article Full text

    Constitutive Modeling of Liver Tissue: Experiment and Theory

    Gao, Zhan; Lister, Kevin; Desai, Jaydev P.

    Ann Biomed Eng · 2009 · English · PubMed Central

    Realistic surgical simulation requires incorporation of the mechanical properties of soft tissue in mathematical models. In actual deformation of soft-tissue during surgical intervention, the tissue is subject to tension, compression, and shear. Therefore, characterization and modeling of…

  13. Journal Article Full text

    Design, Modeling, and Control of a Coaxially Aligned Steerable (COAST) Guidewire Robot

    Jeong, Seokhwan; Chitalia, Yash; Desai, Jaydev P.

    IEEE Robot Autom Lett · 2020 · English · PubMed Central

    Manual navigation of a guidewire is the first step in endovascular interventions. However, this procedure is time consuming with uncertain results due to tortuous vascular anatomy. This paper introduces the design of a novel COaxially Aligned STeerable (COAST) guidewire robot that is 0.40 mm in…

  14. Journal Article Full text

    Force Feedback Plays a Significant Role in Minimally Invasive Surgery

    Tholey, Gregory; Desai, Jaydev P.; Castellanos, Andres E.

    Ann Surg · 2005 · English · PubMed Central

    OBJECTIVE: To evaluate the role of force feedback with applications to minimally invasive surgery (MIS). Two research hypotheses were tested using our automated laparoscopic grasper. SUMMARY BACKGROUND DATA: Conventional laparoscopic tools do not have the ability of providing force feedback to a…

  15. Journal Article Full text

    Design, Analysis, and Evaluation of a Remotely Actuated MRI-Compatible Neurosurgical Robot

    Wang, Xuefeng; Cheng, Shing Shin; Desai, Jaydev P.

    IEEE Robot Autom Lett · 2018 · English · PubMed Central

    The paper presents an MRI-compatible neurosurgical robotic system that is designed to operate the head-mounted meso-scale 6-degree-of-freedom (DoF) spring-based MINIR-II. The robotic system consists of an actuation module, a transmission module, and the robot module. The transmission module consist…

  16. Journal Article Full text

    Active Stiffness Tuning of a Spring-based Continuum Robot for MRI-Guided Neurosurgery

    Kim, Yeongjin; Cheng, Shing Shin; Desai, Jaydev P.

    IEEE Trans Robot · 2017 · English · PubMed Central

    Deep intracranial tumor removal can be achieved if the neurosurgical robot has sufficient flexibility and stability. Towards achieving this goal, we have developed a spring-based continuum robot, namely a Minimally Invasive Neurosurgical Intracranial Robot (MINIR-II) with novel tendon routing and…

  17. Journal Article Full text

    Modeling and characterization of shape memory alloy springs with water cooling strategy in a neurosurgical robot

    Cheng, Shing Shin; Kim, Yeongjin; Desai, Jaydev P.

    J Intell Mater Syst Struct · 2017 · English · PubMed Central

    Since shape memory alloy (SMA) has high power density and is magnetic resonance imaging (MRI) compatible, it has been chosen as the actuator for the meso-scale minimally invasive neurosurgical intracranial robot (MINIR-II) that is envisioned to be operated under continuous MRI guidance. We have…

  18. Journal Article Full text

    New Actuation Mechanism for Actively Cooled SMA Springs in a Neurosurgical Robot

    Cheng, Shing Shin; Kim, Yeongjin; Desai, Jaydev P.

    IEEE Trans Robot · 2017 · English · PubMed Central

    The paper presents the use of shape memory alloy (SMA) spring actuators with real-time cooling to control the motion of the MINIR-II robot. A new actuation mechanism involving the passage of water as the cooling medium and air as the medium to drive out the water has been developed to facilitate…

  19. Journal Article Full text

    MEMS-Based Flexible Force Sensor for Tri-Axial Catheter Contact Force Measurement

    Pandya, Hardik J.; Sheng, Jun; Desai, Jaydev P.

    J Microelectromech Syst · 2016 · English · PubMed Central

    Atrial fibrillation (AFib) is a significant healthcare problem caused by the uneven and rapid discharge of electrical signals from pulmonary veins (PVs). The technique of radiofrequency (RF) ablation can block these abnormal electrical signals by ablating myocardial sleeves inside PVs. Catheter…