24 results for "Ellis, Benjamin J."
Showing 1–20 · 0.19 seconds · RSS
-
Journal Article Full text
Micromechanical Model of a Surrogate for Collagenous Soft Tissues: Development, Validation and Analysis of Mesoscale Size Effects
Aligned, collagenous tissues such as tendons and ligaments are composed primarily of water and type I collagen, organized hierarchically into nanoscale fibrils, microscale fibers and mesoscale fascicles. Force transfer across scales is complex and poorly understood. Since innervation, the…
-
Journal Article Full text
Verification, Validation and Sensitivity Studies in Computational Biomechanics
Computational techniques and software for the analysis of problems in mechanics have naturally moved from their origins in the traditional engineering disciplines to the study of cell, tissue and organ biomechanics. Increasingly complex models have been developed to describe and predict the…
-
Journal Article Full text
EQUIVALENCE BETWEEN SHORT-TIME BIPHASIC AND INCOMPRESSIBLE ELASTIC MATERIAL RESPONSES
Porous-permeable tissues have often been modeled using porous media theories such as the biphasic theory. This study examines the equivalence of the short-time biphasic and incompressible elastic responses for arbitrary deformations and constitutive relations from first principles. This equivalence…
-
Journal Article Full text
FEBio: Finite Elements for Biomechanics
In the field of computational biomechanics, investigators have primarily used commercial software that is neither geared toward biological applications nor sufficiently flexible to follow the latest developments in the field. This lack of a tailored software environment has hampered research…
-
Journal Article Full text
Factors Influencing Cartilage Thickness Measurements with Multi-Detector CT: A Phantom Study
PURPOSE: To prospectively assess in a phantom the reconstruction errors and detection limits of cartilage thickness measurements from MDCT arthrography as a function of contrast agent concentration, imaging plane, spatial resolution, joint space and tube current, using known measurements as the…
-
Journal Article Full text
Effects of Idealized Joint Geometry on Finite Element Predictions of Cartilage Contact Stresses in the Hip
Computational models may have the ability to quantify the relationship between hip morphology, cartilage mechanics and osteoarthritis. Most models have assumed the hip joint to be a perfect ball and socket joint and have neglected deformation at the interface between bone/cartilage. The objective…
-
Journal Article Full text
Finite Element Simulation of Articular Contact Mechanics with Quadratic Tetrahedral Elements
Although it is easier to generate finite element discretizations with tetrahedral elements, trilinear hexahedral (HEX8) elements are more often used in simulations of articular contact mechanics. This is due to numerical shortcomings of linear tetrahedral (TET4) elements, limited availability of…
-
Journal Article Full text
Contributions of Elastic Fibers, Collagen, and Extracellular Matrix to the Multiaxial Mechanics of Ligament
Elastin is a biopolymer known to provide resilience to extensible biologic tissues through elastic recoil of its highly crosslinked molecular network. Recent studies have demonstrated that elastic fibers in ligament provide significant resistance to tensile and especially shear stress. We…
-
Journal Article Full text
Validation of Finite Element Predictions of Cartilage Contact Pressure in the Human Hip Joint
Methods to predict contact stresses in the hip can provide an improved understanding of load distribution in the normal and pathologic joint. The objectives of this study were to develop and validate a three-dimensional finite element (FE) model for predicting cartilage contact stresses in the…
-
Journal Article Full text
Finding Consistent Strain Distributions in the Glenohumeral Capsule Between Two Subjects: Implications for Development of Physical Examinations
The anterior-inferior glenohumeral capsule is the primary passive stabilizer to the glenohumeral joint during anterior dislocation. Physical examinations following dislocation are crucial for proper diagnosis of capsule pathology; however, they are not standardized for joint position which may lead…
-
Journal Article Full text
Continuum Description of the Poisson's Ratio of Ligament and Tendon Under Finite Deformation
Ligaments and tendons undergo volume loss when stretched along the primary fiber axis, which is evident by the large, strain-dependent Poisson's ratios measured during quasi-static tensile tests. Continuum constitutive models that have been used to describe ligament material behavior generally…
-
Journal Article Full text
Muscle connective tissue controls development of the diaphragm and is a source of congenital diaphragmatic hernias
The diaphragm is an essential mammalian skeletal muscle, and defects in diaphragm development are the cause of congenital diaphragmatic hernias (CDH), a common and often lethal birth defect. The diaphragm is derived from multiple embryonic sources, but how these give rise to the diaphragm is…
-
Journal Article Full text
Specimen-specific predictions of contact stress under physiological loading in the human hip: validation and sensitivity studies
Hip osteoarthritis may be initiated and advanced by abnormal cartilage contact mechanics, and finite element (FE) modeling provides an approach with the potential to allow the study of this process. Previous FE models of the human hip have been limited by single specimen validation and the use of…
-
Journal Article Full text
Finite Element Modelling of the Glenohumeral Capsule Can Help Assess the Tested Region during a Clinical Exam
The objective of this research was to examine the efficacy of evaluating the region of the glenohumeral capsule being tested by clinical exams for shoulder instability using finite element models of the glenohumeral joint. Specifically, the regions of high capsule strain produced by glenohumeral…
-
Journal Article Full text
Role of the Acetabular Labrum in Load Support Across the Hip Joint
The relatively high incidence of labral tears among patients presenting with hip pain suggests that the acetabular labrum is often subjected to injurious loading in vivo. However, it is unclear whether the labrum participates in load transfer across the joint during activities of daily living. This…
-
Journal Article Full text
Finite Element Prediction of Cartilage Contact Stresses in Normal Human Hips
Our objectives were to determine cartilage contact stress during walking, stair climbing and descending stairs in a well-defined group of normal volunteers and to assess variations in contact stress and area among subjects and across loading scenarios. Ten volunteers without history of hip pain or…
-
Journal Article Full text
A New Discrete Element Analysis Method for Predicting Hip Joint Contact Stresses
Quantifying cartilage contact stress is paramount to understanding hip osteoarthritis. Discrete element analysis (DEA) is a computationally efficient method to estimate cartilage contact stresses. Previous applications of DEA have underestimated cartilage stresses and yielded unrealistic contact…
-
Journal Article Full text
Effect of Mechanical Boundary Conditions on Orientation of Angiogenic Microvessels
AIM: Mechanical forces are important regulators of cell and tissue phenotype. We hypothesized that mechanical loading and boundary conditions would influence neovessel activity during angiogenesis. METHODS: Using an in vitro model of angiogenesis sprouting and a mechanical loading system, we…
-
Journal Article Full text
Patient-specific Analysis of Cartilage and Labrum Mechanics in Human Hips with Acetabular Dysplasia
BACKGROUND: Acetabular dysplasia is a major predisposing factor for development of hip osteoarthritis, and may result from alterations to chondrolabral loading. Subject-specific finite element (FE) modeling can be used to evaluate chondrolabral mechanics in the dysplastic hip, thereby providing…
-
Journal Article Full text
Finite element predictions of cartilage contact mechanics in hips with retroverted acetabula
BACKGROUND: A contributory factor to hip osteoarthritis (OA) is abnormal cartilage mechanics. Acetabular retroversion, a version deformity of the acetabulum, has been postulated to cause OA via decreased posterior contact area and increased posterior contact stress. Although cartilage mechanics…