21 hasil untuk "Forster, Kenneth"
Menampilkan 1–20 · 0,18 detik · RSS
-
Artikel Jurnal Teks lengkap
Commissioning compensator‐based IMRT on the Pinnacle treatment planning system
We present a systematic approach to commissioning of the compensator‐based IMRT in Pinnacle treatment planning system for commercially manufactured brass compensators. Some model parameters for the beams modulated by the variable‐thickness compensators can only be associated with a single…
-
Artikel Jurnal Teks lengkap
Compensator‐based intensity‐modulated radiation therapy for malignant pleural mesothelioma post extrapleural pneumonectomy
The present work investigated the potential of compensator‐based intensity‐modulated radiation therapy (CB‐IMRT) as an alternative to multileaf collimator (MLC)–based intensity‐modulated radiation therapy (IMRT) to treat malignant pleural mesothelioma (MPM) post extrapleural pneumonectomy…
-
Artikel Jurnal Teks lengkap
Simulation of intrafraction motion and overall geometric accuracy of a frameless intracranial radiosurgery process
We conducted a comprehensive evaluation of the clinical accuracy of an image‐guided frameless intracranial radiosurgery system. All links in the process chain were tested. Using healthy volunteers, we evaluated a novel method to prospectively quantify the range of target motion for optimal…
-
Artikel Jurnal Teks lengkap
Evaluation of a biplanar diode array dosimeter for quality assurance of step‐and‐shoot IMRT
In this paper, we describe and characterize a novel biplanar diode array, and demonstrate its applicability to dosimetric QA of step‐and‐shoot IMRT. It is the first commercially available device of its kind specifically designed for performing measurements at varying gantry angles. The detector…
-
Artikel Jurnal Teks lengkap
Comparing dose in the build‐up region between compensator‐ and MLC‐based IMRT
The build‐up dose in the megavoltage photon beams can be a limiting factor in intensity‐modulated radiation therapy (IMRT) treatments. Excessive surface dose can cause patient discomfort and treatment interruptions, while underdosing may lead to tumor repopulation and local failure. Dose in the…
-
Artikel Jurnal Teks lengkap
Quality assurance evaluation of delivery of respiratory‐gated treatments
We describe a method for evaluating the quality of respiratory‐gated radiation delivery using a commercially available device. During irradiation, gating traces for one field for each treatment were extracted from the system for each of 14 patients. The data were then transferred to a spreadsheet…
-
Artikel Jurnal Teks lengkap
Validation of three deformable image registration algorithms for the thorax
Deformable image registration (DIR) has been proposed for lung ventilation calculation using 4D CT. Spatial accuracy of DIR can be evaluated using expert landmark correspondences. Additionally, image differences between the deformed and the target images give a degree of accuracy of DIR algorithms…
-
Artikel Jurnal Teks lengkap
Speech motor planning in the context of phonetically similar words: Evidence from apraxia of speech and aphasia
The purpose of this study was to test two competing hypotheses about the nature of the impairment in apraxia of speech (AOS). The Reduced Buffer Capacity Hypothesis argues that people with AOS can hold only one syllable at a time in the speech motor planning buffer. The Program Retrieval Deficit…
-
Artikel Jurnal Teks lengkap
Providing a fast conversion of total dose to biological effective dose (BED) for hybrid seed brachytherapy
Optimization of permanent seed implant brachytherapy plans for treatment of prostate cancer should be based on biological effective dose (BED) distributions, since dose does not accurately represent biological effects between different types of sources. Currently, biological optimization for these…
-
Artikel Jurnal Teks lengkap
Examining speech motor planning difficulties in apraxia of speech and aphasia via the sequential production of phonetically similar words
This study investigated the underlying nature of apraxia of speech (AOS) by testing two competing hypotheses. The Reduced Buffer Capacity Hypothesis argues that people with AOS can plan speech only one syllable at a time (Rogers & Storkel, 1999). The Program Retrieval Deficit Hypothesis states that…
-
Artikel Jurnal Teks lengkap
Dependence of ventilation image derived from 4D CT on deformable image registration and ventilation algorithms
Ventilation imaging using 4D CT is a convenient and low‐cost functional imaging methodology which might be of value in radiotherapy treatment planning to spare functional lung volumes. Deformable image registration (DIR) is needed to calculate ventilation imaging from 4D CT. This study investigates…
-
Artikel Jurnal Teks lengkap
Dosimetric benefits of respiratory gating: a preliminary study
In this study, we compared the amount of lung tissue irradiated when respiratory gating was imposed during expiration with the amount of lung tissue irradiated when gating was imposed during inspiration. Our hypothesis was that the amount of lung tissue spared increased as inspiration increased…
-
Artikel Jurnal Teks lengkap
Dose-Volume Predictors of Radiation Pneumonitis After Lung Stereotactic Body Radiation Therapy (SBRT): Implications for Practice and Trial Design
Background and purpose Recently published HyTEC report summarized lung toxicity data and proposed guidelines of mean lung dose (MLD)
-
Artikel Jurnal Teks lengkap
Targeting Accuracy Considerations for Simultaneous Tumor Treating Fields Antimitotic Therapy During Robotic Hypofractionated Radiation Therapy
Purpose: Tumor treating fields (TTFields) is a novel antimitotic treatment that was first proven effective for glioblastoma multiforme, now with trials for several extracranial indications underway. Several studies focused on concurrent TTFields therapy with radiation in the same time period, but…
-
Artikel Jurnal Teks lengkap
Estimating the tolerance of brachial plexus to hypofractionated stereotactic body radiotherapy: a modelling-based approach from clinical experience
BACKGROUND: Brachial plexopathy is a potentially serious complication from stereotactic body radiation therapy (SBRT) that has not been widely studied. Therefore, we compared datasets from two different institutions and generated a brachial plexus dose–response model, to quantify what dose…
-
Artikel Jurnal Teks lengkap
Radiation dosimetry and biodistribution of (99m)Tc-ethylene dicysteine-deoxyglucose in patients with non-small-cell lung cancer
PURPOSE: To assess the radiation dosimetry and biodistribution of (99m)Tc-labeled ethylene dicysteine deoxyglucose ((99m)Tc-EC-DG) in patients with non-small-cell lung cancer (NSCLC). METHODS: Serial whole-body scans were acquired 0, 2, 4, 6 and 24 h after injection of (99m)Tc-EC-DG (925 MBq) in…
-
Artikel Jurnal Teks lengkap
QIN. Promise and pitfalls of quantitative imaging in oncology clinical trials
Quantitative imaging using CT, MRI, and PET modalities will play an increasingly important role in the design of oncology trials addressing molecularly targeted, personalized therapies. The advent of molecularly targeted therapies, exemplified by antiangiogenic drugs, creates new complexities in…
-
Artikel Jurnal Teks lengkap
QIN “Radiomics: The Process and the Challenges”
“Radiomics” refers to the extraction and analysis of large amounts of advanced quantitative imaging features with high throughput from medical images obtained with computed tomography (CT), positron emission tomography (PET) or magnetic resonance imaging (MRI). Importantly, these data are designed…
-
Artikel Jurnal Teks lengkap
Potential Clinical Significance of Overall Targeting Accuracy and Motion Management in the Treatment of Tumors That Move With Respiration: Lessons Learnt From a Quarter Century of Stereotactic Body Radiotherapy From Dose Response Models
OBJECTIVE: To determine the long-term normal tissue complication probability with stereotactic body radiation therapy (SBRT) treatments for targets that move with respiration and its relation with the type of respiratory motion management (tracking vs. compression or gating). METHODS: A PubMed…
-
Artikel Jurnal Teks lengkap
Standard-dose versus high-dose conformal radiotherapy with concurrent and consolidation carboplatin plus paclitaxel with or without cetuximab for patients with stage IIIA or IIIB non-small-cell lung cancer (RTOG 0617): a randomised, two-by-two factorial phase 3 study
BACKGROUND: We aimed to compare overall survival after standard-dose versus high-dose conformal radiotherapy with concurrent chemotherapy and the addition of cetuximab to concurrent chemoradiation for patients with inoperable stage III non-small-cell lung cancer. METHODS: In this open-label…