Biblio Discovery — Demo Discovery Service

16 hasil untuk "Fuchs, Hermann"

Menampilkan 1–16 · 1,44 detik · RSS

  1. Artikel Jurnal Teks lengkap

    A pencil beam algorithm for magnetic resonance image‐guided proton therapy

    Padilla‐Cabal, Fatima; Georg, Dietmar; Fuchs, Hermann

    Med Phys · 2018 · Inggris · PubMed Central

    PURPOSE: The feasibility of magnetic resonance image (MRI)‐based proton therapy is based, among several other factors, on the implementation of appropriate extensions on current dose calculation methods. This work aims to develop a pencil beam algorithm (PBA) for dose calculation of proton beams…

  2. Artikel Jurnal Teks lengkap

    Technical Note: Design and commissioning of a water phantom for proton dosimetry in magnetic fields

    Fuchs, Hermann; Padilla‐Cabal, Fatima; Hummel, Andreas dkk.

    Med Phys · 2020 · Inggris · PubMed Central

    PURPOSE: To design and commission a water phantom suitable for constrained environments and magnetic fields for magnetic resonance (MR)‐guided proton therapy. METHODS: A phantom was designed, to enable precise, remote controlled detector positioning in water within the constrained environment of a…

  3. Artikel Jurnal Teks lengkap

    MR‐guided proton therapy: Impact of magnetic fields on the detector response

    Fuchs, Hermann; Padilla‐Cabal, Fatima; Zimmermann, Lukas dkk.

    Med Phys · 2021 · Inggris · PubMed Central

    PURPOSE: To investigate the response of detectors for proton dosimetry in the presence of magnetic fields. MATERIAL AND METHODS: Four ionization chambers (ICs), two thimble‐type and two plane‐parallel‐type, and a diamond detector were investigated. All detectors were irradiated with homogeneous…

  4. Artikel Jurnal Teks lengkap

    Dosimetry in MRgPT: Impact of magnetic fields on TLD dose response during proton irradiation

    Fuchs, Hermann; Palmans, Hugo; Heilemann, Gerd dkk.

    Med Phys · 2024 · Inggris · PubMed Central

    BACKGROUND: Proton beam therapy, when integrated with MRI guidance, presents complex dosimetric challenges due to interactions with magnetic fields. Prior research has emphasized the nuanced impact of magnetic fields on dosimetry. For thermoluminescent dosimeters (TLDs) the electron‐return effect…

  5. Artikel Jurnal Teks lengkap

    Benchmarking a GATE/Geant4 Monte Carlo model for proton beams in magnetic fields

    Padilla‐Cabal, Fatima; Alejandro Fragoso, Jose; Franz Resch, Andreas dkk.

    Med Phys · 2019 · Inggris · PubMed Central

    PURPOSE: Magnetic resonance guidance in proton therapy (MRPT) is expected to improve its current performance. The combination of magnetic fields with clinical proton beam lines poses several challenges for dosimetry, treatment planning and dose delivery. Proton beams are deflected by magnetic…

  6. Artikel Jurnal Teks lengkap

    Characterization of EBT3 radiochromic films for dosimetry of proton beams in the presence of magnetic fields

    Padilla‐Cabal, Fatima; Kuess, Peter; Georg, Dietmar dkk.

    Med Phys · 2019 · Inggris · PubMed Central

    PURPOSE: Radiochromic film dosimetry is extensively used for quality assurance in photon and proton beam therapy. So far, GafchromicTM EBT3 film appears as a strong candidate to be used in future magnetic resonance (MR) based therapy systems. The response of Gafchromic EBT3 films in the presence of…

  7. Artikel Jurnal Teks lengkap

    Radiobiological Assessment of Targeted Radionuclide Therapy with [(177)Lu]Lu-PSMA-I&T in 2D vs. 3D Cell Culture Models

    Raitanen, Julia; Barta, Bernadette; Fuchs, Hermann dkk.

    Int J Mol Sci · 2023 · Inggris · PubMed Central

    In vitro therapeutic efficacy studies are commonly conducted in cell monolayers. However, three-dimensional (3D) tumor spheroids are known to better represent in vivo tumors. This study used [(177)Lu]Lu-PSMA-I&T, an already clinically applied radiopharmaceutical for targeted radionuclide therapy…

  8. Artikel Jurnal Teks lengkap

    Dose‐ rather than fluence‐averaged LET should be used as a single‐parameter descriptor of proton beam quality for radiochromic film dosimetry

    Resch, Andreas Franz; Heyes, Paul David; Fuchs, Hermann dkk.

    Med Phys · 2020 · Inggris · PubMed Central

    PURPOSE: The dose response of Gafchromic EBT3 films exposed to proton beams depends on the dose, and additionally on the beam quality, which is often quantified with the linear energy transfer (LET) and, hence, also referred to as LET quenching. Fundamentally different methods to determine…

  9. Artikel Jurnal Teks lengkap

    An external perpendicular magnetic field does not influence survival and DNA damage after proton and carbon ion irradiation in human cancer cells

    Kerschbaum-Gruber, Sylvia; Padilla-Cabal, Fatima; Mara, Elisabeth dkk.

    Z Med Phys · 2022 · Inggris · PubMed Central

    BACKGROUND AND PURPOSE: Magnetic field effects on the radiobiological effectiveness during treatment of magnetic resonance (MRI) guided particle therapy are being debated. This study aims at assessing the influence of a perpendicular magnetic field on the biological effects in two human cancer cell…

  10. Artikel Jurnal Teks lengkap

    Efficient full Monte Carlo modelling and multi-energy generative model development of an advanced X-ray device

    Fuchs, Hermann; Zimmermann, Lukas; Reisz, Niklas dkk.

    Z Med Phys · 2022 · Inggris · PubMed Central

    Monte Carlo (MC) simulations of X-ray image devices require splitting the simulation into two parts (i.e. the generation of x-rays and the actual imaging). The X-ray production remains unchanged for repeated imaging and can thus be stored in phase space (PhS) files and used for subsequent MC…

  11. Artikel Jurnal Teks lengkap

    Evaluation of electromagnetic and nuclear scattering models in GATE/Geant4 for proton therapy

    Resch, Andreas F.; Elia, Alessio; Fuchs, Hermann dkk.

    Med Phys · 2019 · Inggris · PubMed Central

    PURPOSE: The dose core of a proton pencil beam (PB) is enveloped by a low dose area reaching several centimeters off the central axis and containing a considerable amount of the dose. Adequate modeling of the different components of the PB profile is, therefore, required for accurate dose…

  12. Artikel Jurnal Teks lengkap

    Computer‐assisted beam modeling for particle therapy

    Fuchs, Hermann; Elia, Alessio; Resch, Andreas F. dkk.

    Med Phys · 2020 · Inggris · PubMed Central

    PURPOSE: To develop a computer‐driven and thus less user‐dependent method, allowing for a simple and straightforward generation of a Monte Carlo (MC) beam model of a scanned proton and carbon ion beam delivery system. METHODS: In a first step, experimental measurements were performed for proton and…

  13. Artikel Jurnal Teks lengkap

    Implementation of Sphinx/Lynx as daily QA equipment for scanned proton and carbon ion beams

    Grevillot, Loïc; Moreno, Jhonnatan Osorio; Fuchs, Hermann dkk.

    J Appl Clin Med Phys · 2023 · Inggris · PubMed Central

    PURPOSE: Reporting on the first implementation of a proton dedicated commercial device (IBA Sphinx/Lynx) for daily Quality Assurance (QA) of scanned proton and carbon ion beams. METHODS: Daily QA trendlines over more than 3 years for protons and more than 2 years for carbon ions have been acquired…

  14. Artikel Jurnal Teks lengkap

    The OpenGATE ecosystem for Monte Carlo simulation in medical physics

    Sarrut, David; Arbor, Nicolas; Baudier, Thomas dkk.

    Phys Med Biol · 2022 · Inggris · PubMed Central

    This paper reviews the ecosystem of GATE, an open-source Monte Carlo toolkit for medical physics. Based on the shoulders of Geant4, the principal modules (geometry, physics, scorers) are described with brief descriptions of some key concepts (Volume, Actors, Digitizer). The main source code…

  15. Artikel Jurnal Teks lengkap

    GATE Monte Carlo simulation toolkit for medical physics

    Kochebina Olga; Sarrut David; Arbor Nicolas dkk.

    EPJ Web of Conferences, Vol. 302 · 2024 · Inggris · DOAJ

    The GATE toolkit (GEANT4 Application for Tomographic Emission) is a GEANT4-based (GEometry ANd Tracking) platform for Monte Carlo simulations in medical physics. GATE applications can be divided into two main axes: radiation-based medical imaging and radiotherapy/dosimetry. The accurate modeling of…