Biblio Discovery — Demo Discovery Service

41 results for "Hartnell, Sara"

Showing 1–20 · 3.11 seconds · RSS

  1. Journal Article Full text

    Hybrid Closed-loop to Manage Gastroparesis in People With Type 1 Diabetes: a Case Series

    Daly, Aideen; Hartnell, Sara; Boughton, Charlotte K. et al.

    J Diabetes Sci Technol · 2021 · English · PubMed Central

    BACKGROUND: Gastroparesis is associated with unpredictable gastric emptying and can lead to erratic glucose profiles and negative impacts on quality-of-life. Many people with gastroparesis are unable to meet glycemic targets and there is a need for new approaches for this population. Hybrid…

  2. Journal Article Full text

    Real-World Evidence of the Cambridge Hybrid Closed-Loop App With a Novel Real-Time Continuous Glucose Monitoring System

    Newman, Christine; Hartnell, Sara; Wilinska, Malgorzata et al.

    J Diabetes Sci Technol · 2023 · English · PubMed Central

    We evaluated the performance of the interoperable Cambridge hybrid closed-loop app with FreeStyle Libre 3 glucose sensor, and YpsoPump insulin pump in a real-world setting. Data from 100 users (63 adults [mean ± SD age 41.9 ± 14.0 years], 15 children [8.6 ± 5.2 years)] and 22 users of unreported…

  3. Journal Article Full text

    Training and Support for Hybrid Closed-Loop Therapy

    Boughton, Charlotte K.; Hartnell, Sara; Allen, Janet M. et al.

    J Diabetes Sci Technol · 2020 · English · PubMed Central

    Hybrid closed-loop therapy is an emerging technology transforming the management of type 1 diabetes (T1D). Research studies demonstrate glycemic and quality of life benefits of hybrid closed-loop therapy for people with T1D. Translating these outcomes into standard clinical practice is critical for…

  4. Journal Article Full text

    Fully automated closed-loop insulin delivery in adults with type 2 diabetes: an open-label, single-center, randomized crossover trial

    Daly, Aideen B.; Boughton, Charlotte K.; Nwokolo, Munachiso et al.

    Nat Med · 2023 · English · PubMed Central

    In adults with type 2 diabetes, the benefits of fully closed-loop insulin delivery, which does not require meal bolusing, are unclear. In an open-label, single-center, randomized crossover study, 26 adults with type 2 diabetes (7 women and 19 men; (mean ± s.d.) age, 59 ± 11 years; baseline glycated…

  5. Journal Article Full text

    Lived Experience of Fully Closed-Loop Insulin Delivery in Adults with Type 1 Diabetes

    Lakshman, Rama; Hartnell, Sara; Ware, Julia et al.

    Diabetes Technol Ther · 2024 · English · PubMed Central

    INTRODUCTION: The Closing the Loop in Adults With Type 1 Diabetes (CLEAR) randomized crossover study compared a novel fully closed-loop insulin delivery system with no carbohydrate entry or mealtime bolusing (CamAPS HX), with standard insulin pump therapy and glucose sensor in adults with type 1…

  6. Journal Article Full text

    Healthcare professionals' views about how pregnant women can benefit from using a closed‐loop system: Qualitative study

    Lawton, Julia; Rankin, David; Hartnell, Sara et al.

    Diabet Med · 2023 · English · PubMed Central

    BACKGROUND: Interest is growing in how closed‐loop systems can support attainment of within‐target glucose levels amongst pregnant women with type 1 diabetes. We explored healthcare professionals' views about how, and why, pregnant women benefitted from using the CamAPS FX system during the AiDAPT…

  7. Journal Article Full text

    Fully automated closed-loop glucose control compared with standard insulin therapy in adults with type 2 diabetes requiring dialysis: an open-label, randomized crossover trial

    Boughton, Charlotte K.; Tripyla, Afroditi; Hartnell, Sara et al.

    Nat Med · 2021 · English · PubMed Central

    We evaluated the safety and efficacy of fully closed-loop insulin therapy compared with standard insulin therapy in adults with type 2 diabetes requiring dialysis. In an open-label, multinational, two-center, randomized crossover trial, 26 adults with type 2 diabetes requiring dialysis (17 men, 9…

  8. Journal Article Full text

    CamAPS FX Hybrid Closed-Loop with Ultra-Rapid Lispro Compared with Standard Lispro in Adults with Type 1 Diabetes: A Double-Blind, Randomized, Crossover Study

    Nwokolo, Munachiso; Lakshman, Rama; Hartnell, Sara et al.

    Diabetes Technol Ther · 2023 · English · PubMed Central

    INTRODUCTION: To evaluate hybrid closed-loop with ultra-rapid insulin lispro (Lyumjev) compared with hybrid closed-loop with standard insulin lispro in adults with type 1 diabetes. MATERIALS AND METHODS: In a single-center, double-blind, randomized, crossover study, 28 adults with type 1 diabetes…

  9. Journal Article Full text

    Lived experience of fully closed-loop insulin delivery in adolescents with type 1 diabetes and HbA1c above target

    Kadiyala, Nithya; Allen, Janet; Lakshman, Rama et al.

    Diabetes Technol Ther · 2025 · English · PubMed Central

    AIMS: The aim of this qualitative study was to explore the impact of using the CamAPS HX fully closed-loop system, which does not require carbohydrate counting, meal announcements or premeal bolusing, on the daily lives of adolescents with type 1 diabetes and HbA1c above the recommended target (≥…

  10. Journal Article Full text

    Fully closed-loop insulin delivery in inpatients receiving nutritional support: a two-centre, open-label, randomised controlled trial

    Boughton, Charlotte K; Bally, Lia; Martignoni, Franco et al.

    Lancet Diabetes Endocrinol · 2019 · English · PubMed Central

    BACKGROUND: Glucose management is challenging in patients who require nutritional support in hospital. We aimed to assess whether fully closed-loop insulin delivery would improve glycaemic control compared with conventional subcutaneous insulin therapy in inpatients receiving enteral or parenteral…

  11. Journal Article Full text

    Listening to Women: Experiences of Using Closed-Loop in Type 1 Diabetes Pregnancy

    Lawton, Julia; Kimbell, Barbara; Closs, Mia et al.

    Diabetes Technol Ther · 2023 · English · PubMed Central

    INTRODUCTION: Recent high-profile calls have emphasized that women's experiences should be considered in maternity care provisioning. We explored women's experiences of using closed-loop during type 1 diabetes (T1D) pregnancy to inform decision-making about antenatal rollout and guidance and…

  12. Journal Article Full text

    Hypoglycemia and Hyperglycemia According to Type of Diabetes: Observations During Fully Closed-Loop Insulin Delivery in Adults With Type 1 and Type 2 Diabetes

    Kadiyala, Nithya; Wilinska, Malgorzata E.; Daly, Aideen B. et al.

    J Diabetes Sci Technol · 2024 · English · PubMed Central

    BACKGROUND: CamAPS HX fully closed-loop (FCL) system, with no user input required at mealtimes, has been shown to be safe and effective in adults with type 1 and type 2 diabetes. We assessed whether time spent in hypoglycemia and hyperglycemia during FCL insulin delivery in adults varied by type of…

  13. Journal Article Full text

    Day-and-night glycaemic control with closed-loop insulin delivery versus conventional insulin pump therapy in free-living adults with well controlled type 1 diabetes: an open-label, randomised, crossover study

    Bally, Lia; Thabit, Hood; Kojzar, Harald et al.

    Lancet Diabetes Endocrinol · 2017 · English · PubMed Central

    BACKGROUND: Tight control of blood glucose concentration in people with type 1 diabetes predisposes to hypoglycaemia. We aimed to investigate whether day-and-night hybrid closed-loop insulin delivery can improve glucose control while alleviating the risk of hypoglycaemia in adults with HbA(1c)…

  14. Journal Article Full text

    Behavioral Patterns and Associations with Glucose Control During 12-Week Randomized Free-Living Clinical Trial of Day and Night Hybrid Closed-Loop Insulin Delivery in Adults with Type 1 Diabetes

    Emami, Ali; Willinska, Malgorzata E.; Thabit, Hood et al.

    Diabetes Technol Ther · 2017 · English · PubMed Central

    Objectives: We evaluated patterns of meal intake, insulin bolus delivery, and fingerstick glucose measurements during hybrid closed-loop and sensor-augmented pump (SAP) therapy, including associations with glucose control. Methods: Data were retrospectively analyzed from pump-treated adults with…

  15. Journal Article Full text

    Hybrid closed-loop glucose control compared with sensor augmented pump therapy in older adults with type 1 diabetes: an open-label multicentre, multinational, randomised, crossover study

    Boughton, Charlotte K; Hartnell, Sara; Thabit, Hood et al.

    Lancet Healthy Longev · 2022 · English · PubMed Central

    BACKGROUND: Older adults with type 1 diabetes have distinct characteristics that can make optimising glycaemic control challenging. We sought to test our hypothesis that hybrid closed-loop glucose control is safe and more effective than sensor-augmented pump (SAP) therapy in older adults with type…

  16. Journal Article Full text

    Impact of Ultra-Rapid Insulin on Boost and Ease-Off in the Cambridge Hybrid Closed-Loop System for Individuals With Type 1 Diabetes

    Royston, Chloë; Boughton, Charlotte; Nwokolo, Munachiso et al.

    J Diabetes Sci Technol · 2024 · English · PubMed Central

    OBJECTIVE: The objective was to evaluate the safety and efficacy of ultra–rapid-acting insulin with the Boost and Ease-off features of the Cambridge hybrid closed-loop system. METHODS: A secondary analysis of Boost and Ease-off from two double-blind, randomized, crossover hybrid closed-loop studies…

  17. Journal Article Full text

    Trends in total daily dose and variability of insulin requirements in newly diagnosed children and adolescents with type 1 diabetes over 48 months

    Royston, Chloë; Ware, Julia; Allen, Janet M. et al.

    Diabetes Technol Ther · 2025 · English · PubMed Central

    OBJECTIVE: To evaluate trends in insulin delivery and day-to-day variability of insulin requirements over 48 months of hybrid closed-loop use following diagnosis of type 1 diabetes in individuals aged 10 to 16 years. METHODS: A secondary analysis of the closed-loop arm of an open-label…