74 hasil untuk "Heise, Tim"
Menampilkan 1–20 · 0,29 detik · RSS
-
Artikel Jurnal Teks lengkap
Impact of the mode of protraction of basal insulin therapies on their pharmacokinetic and pharmacodynamic properties and resulting clinical outcomes
Manufacturers of insulin products for diabetes therapy have long sought ways to modify the absorption rate of exogenously administered insulins in an effort to better reproduce the naturally occurring pharmacokinetics of endogenous insulin secretion. Several mechanisms of protraction have been used…
-
Artikel Jurnal Teks lengkap
A Review of the Pharmacological Properties of Insulin Degludec and Their Clinical Relevance
Insulin degludec (IDeg) is a new-generation basal insulin with an ultra-long duration of action. To date, a large number of studies have been conducted to investigate the pharmacokinetic and pharmacodynamic properties of IDeg. Standardised methods for collection and analysis of blood samples (for…
-
Artikel Jurnal Teks lengkap
Fast-Acting Insulin Aspart: A Review of its Pharmacokinetic and Pharmacodynamic Properties and the Clinical Consequences
Fast-acting insulin aspart (faster aspart) is insulin aspart (IAsp) with two added excipients, l-arginine and niacinamide, to ensure formulation stability with accelerated initial absorption after subcutaneous administration compared with previously developed rapid-acting insulins. The…
-
Artikel Jurnal Teks lengkap
Biosimilar insulins: Narrative review of the regulatory framework and registration studies
Biosimilar insulins have been commercially available in the EU since 2014. Currently, six biosimilar insulins are approved in the EU and four in the US. However, commercial success has been limited, which may be in part due to concerns among physicians and people with diabetes that biosimilar…
-
Artikel Jurnal Teks lengkap
Inhaled Insulin: Take a Deep Breath, but How?
Inhalation of insulin is the first alternative route of insulin administration, which has been developed to such a mature status that the first product (Exubera®, Pfizer) was made available to the market and subsequently withdrawn as of early 2008. In view of the relatively low bioavailability of…
-
Artikel Jurnal Teks lengkap
Considering Blood Dilution improves the Precision of Continuous Whole Blood Glucose Measurements
BACKGROUND: One major advantage of automated over manual clamps are continuous measurements of blood glucose concentrations (BG) allowing frequent adaptations in glucose infusion rates (GIR). However, BG measurements might be affected by changes in blood dilution. ClampArt®, a modern automated…
-
Artikel Jurnal Teks lengkap
Comparison of Pharmacokinetics and Pharmacodynamics of Inhaled Technosphere Insulin and Subcutaneous Insulin Lispro in the Treatment of Type 1 Diabetes Mellitus
BACKGROUND: This study was performed to satisfy a US Food and Drug Administration post-marketing requirement to compare the dose responses for Technosphere(®) Insulin (TI; MannKind Corporation, Westlake Village, CA, USA) and subcutaneous insulin lispro (LIS) across a wide range of doses…
-
Artikel Jurnal Teks lengkap
Day-to-Day and Within-Day Variability in Glucose-Lowering Effect Between Insulin Degludec and Insulin Glargine (100 U/mL and 300 U/mL): A Comparison Across Studies
BACKGROUND: Insulin degludec (IDeg) has significantly lower day-to-day and within-day variability compared to insulin glargine (IGlar) 100U/mL (U100) and 300U/mL (U300). Here, we report post hoc assessments to confirm the robustness of these observations while accounting for potential experimental…
-
Artikel Jurnal Teks lengkap
A Review of Insulin Degludec/Insulin Aspart: Pharmacokinetic and Pharmacodynamic Properties and Their Implications in Clinical Use
Insulin degludec/insulin aspart (IDegAsp; 70 % IDeg and 30 % IAsp) is a soluble combination of two individual insulin analogues in one product, designed to provide mealtime glycaemic control due to the IAsp component and basal glucose-lowering effect from the IDeg component. The pharmacokinetic and…
-
Artikel Jurnal Teks lengkap
Common Standards of Basal Insulin Titration in T2DM
Type 2 diabetes mellitus has become a worldwide major health problem, and the number of people affected is steadily increasing. Thus, not all patients suffering from the disease can be treated by specialized diabetes centers or outpatient clinics, but by primary care physicians. The latter…
-
Artikel Jurnal Teks lengkap
Pharmacokinetic and pharmacodynamic bioequivalence of proposed biosimilar MYL‐1501D with US and European insulin glargine formulations in patients with type 1 diabetes mellitus
AIMS: To report phase 1 bioequivalence results comparing MYL‐1501D, US reference insulin glargine (US IG), and European reference insulin glargine (EU IG). MATERIALS AND METHODS: The double‐blind, randomized, three‐way crossover study compared the pharmacokinetic (PK) and pharmacodynamic (PD)…
-
Artikel Jurnal Teks lengkap
New Clamp-PID Algorithm for Automated Glucose Clamps Improves Clamp Quality
BACKGROUND: In automated glucose clamp experiments, blood glucose (BG) concentrations are kept close to a predefined target level using variable glucose infusion rates (GIRs) determined by implemented algorithms. Clamp quality (ie, the ability to keep BG close to target) highly depends on the…
-
Artikel Jurnal Teks lengkap
Inhaled Technosphere® Insulin in Comparison to Subcutaneous Regular Human Insulin: Time Action Profile and Variability in Subjects with Type 2 Diabetes
BACKGROUND: This study assessed time action profile and within- and between-subject variability of inhaled Technosphere® Insulin (TI) compared with subcutaneous regular human insulin (sc RHI). METHODS: Thirteen subjects with type 2 diabetes (age 56 ± 7 years, body mass index 30.4 ± 3.0 kg·m(-2)…
-
Artikel Jurnal Teks lengkap
Pharmacological properties of faster‐acting insulin aspart vs insulin aspart in patients with type 1 diabetes receiving continuous subcutaneous insulin infusion: A randomized, double‐blind, crossover trial
AIM: To evaluate the pharmacological characteristics of faster‐acting insulin aspart (faster aspart) compared with insulin aspart (IAsp) during continuous subcutaneous insulin infusion (CSII). METHODS: In this randomized, double‐blind, crossover trial, 48 men and women aged 18 to 64 years with type…
-
Artikel Jurnal Teks lengkap
How to Assess the Quality of Glucose Clamps? Evaluation of Clamps Performed With ClampArt, a Novel Automated Clamp Device
BACKGROUND: There are no widely accepted parameters to assess the quality of glucose clamps. Thus, we selected different parameters describing clamp quality. These parameters were then evaluated in glucose clamps carried out with ClampArt, a novel CE-marked, state-of-the-art fully automated glucose…
-
Artikel Jurnal Teks lengkap
A Pooled Analysis of Clinical Pharmacology Trials Investigating the Pharmacokinetic and Pharmacodynamic Characteristics of Fast-Acting Insulin Aspart in Adults with Type 1 Diabetes
BACKGROUND: Fast-acting insulin aspart (faster aspart) is insulin aspart (IAsp) in a new formulation aiming to mimic the fast endogenous prandial insulin release more closely than currently available insulin products. In a post hoc analysis of pooled data from six clinical pharmacology trials, the…
-
Artikel Jurnal Teks lengkap
Selective Inhibition of 11beta-Hydroxysteroiddehydrogenase-1 with BI 187004 in Patients with Type 2 Diabetes and Overweight or Obesity: Safety, Pharmacokinetics, and Pharmacodynamics After Multiple Dosing Over 14 Days
Objective To assess safety, tolerability, pharmacokinetics, and pharmacodynamics of treatment with the selective 11beta-hydroxysteroid dehydrogenase-1 (11beta-HSD1) inhibitor BI 187004 in male and female patients with type 2 diabetes and overweight or obesity. Methods Randomized, double-blind…
-
Artikel Jurnal Teks lengkap
Safety, tolerability, pharmacodynamics and pharmacokinetics following once‐daily doses of BI 187004, an inhibitor of 11 beta‐hydroxysteroid dehydrogenase‐1, over 28 days in patients with type 2 diabetes mellitus and overweight or obesity
AIMS: To study the oral 11 beta‐hydroxysteroid dehydrogenase‐1 (11β‐HSD1) inhibitor BI 187004 (NCT02150824), as monotherapy and in combination with metformin, versus placebo in patients with type 2 diabetes mellitus (T2DM) affected by overweight or obesity. MATERIALS AND METHODS: This Phase II…
-
Artikel Jurnal Teks lengkap
Distinct Prandial and Basal Glucose-Lowering Effects of Insulin Degludec/Insulin Aspart (IDegAsp) at Steady State in Subjects with Type 1 Diabetes Mellitus
INTRODUCTION/AIM: Insulin degludec/insulin aspart (IDegAsp) is a soluble co-formulation of long-acting and short-acting insulin analogs. The primary objective of this study was to investigate the pharmacodynamic response of once-daily IDegAsp dosing in patients with type 1 diabetes. Pharmacokinetic…
-
Artikel Jurnal Teks lengkap
Automated Near-Continuous Glucose Monitoring Measured in Plasma Using Mid-Infrared Spectroscopy
OBJECTIVE: There are increasing calls for a precise, automated system to enable tight glycemic control and to avoid hypoglycemia in an intensive care unit setting. OptiScan Biomedical has developed a glucose monitor based on mid-infrared spectroscopy that withdraws blood samples (120 µl) and…