21 hasil untuk "Horner, Marc"
Menampilkan 1–20 · 0,45 detik · RSS
-
Artikel Jurnal Teks lengkap
Modeling radiofrequency responses of realistic multi-electrode leads containing helical and straight wires
PURPOSE: To present a modeling workflow for the evaluation of a lead electromagnetic model (LEM) consisting of a transfer function (TF) and a calibration factor. The LEM represents an analytical relationship between the RF response of a lead and the incident electromagnetic field. The study also…
-
Artikel Jurnal Teks lengkap
Simulating Dissolution of Intravitreal Triamcinolone Acetonide Suspensions in an Anatomically Accurate Rabbit Eye Model
PURPOSE: A computational fluid dynamics (CFD) study examined the impact of particle size on dissolution rate and residence of intravitreal suspension depots of Triamcinolone Acetonide (TAC). METHODS: A model for the rabbit eye was constructed using insights from high-resolution NMR imaging studies…
-
Buku Teks lengkap
Brain and Human Body Modeling
This open access book describes modern applications of computational human modeling with specific emphasis in the areas of neurology and neuroelectromagnetics, depression and cancer treatments, radio-frequency studies and wireless communications. Special consideration is also given to the use of…
Juga tersedia di: OAPEN
-
Artikel Jurnal Teks lengkap
A uniform-shear rate microfluidic bioreactor for real-time study of proplatelet formation and rapidly-released platelets
Platelet transfusions, with profound clinical importance in blood clotting and wound healing, are entirely derived from human volunteer donors. Hospitals rely on a steady supply of donations, but these methods are limited by a 5-day shelf life, the potential risk of contamination, and differences…
-
Artikel Jurnal Teks lengkap
Modeling radio-frequency energy-induced heating due to the presence of transcranial electric stimulation setup at 3T
PURPOSE: The purpose of the present study was to develop a numerical workflow for simulating temperature increase in a high-resolution human head and torso model positioned in a whole-body magnetic resonance imaging (MRI) radio-frequency (RF) coil in the presence of a transcranial electric…
-
Artikel Jurnal Teks lengkap
In silico trials: Verification, validation and uncertainty quantification of predictive models used in the regulatory evaluation of biomedical products
Historically, the evidences of safety and efficacy that companies provide to regulatory agencies as support to the request for marketing authorization of a new medical product have been produced experimentally, either in vitro or in vivo. More recently, regulatory agencies started receiving and…
-
Artikel Jurnal Teks lengkap
Assessing Computational Model Credibility Using a Risk-Based Framework: Application to Hemolysis in Centrifugal Blood Pumps
Medical device manufacturers using computational modeling to support their device designs have traditionally been guided by internally developed modeling best practices. A lack of consensus on the evidentiary bar for model validation has hindered broader acceptance, particularly in regulatory…
-
Artikel Jurnal Teks lengkap
A System for Optimizing Medical Device Development Using Finite Element Analysis Predictions
-
Artikel Jurnal Teks lengkap
CANNULATION STRATEGY FOR AORTIC ARCH RECONSTRUCTION USING DEEP HYPOTHERMIC CIRCULATORY ARREST
BACKGROUND: Aortic arch reconstruction in neonates is commonly performed using deep hypothermic circulatory arrest. However, concerns have arisen regarding potential adverse neurologic outcomes from this complex procedure, raising questions as to best arterial cannulation approach for cerebral…
-
Artikel Jurnal Teks lengkap
In Silico Fit Evaluation of Additively Manufactured Face Coverings
In response to the respiratory protection device shortage during the COVID-19 pandemic, the additive manufacturing (AM) community designed and disseminated numerous AM face masks. Questions regarding the effectiveness of AM masks arose because these masks were often designed with limited (if any)…
-
Artikel Jurnal Teks lengkap
Use of the FDA nozzle model to illustrate validation techniques in computational fluid dynamics (CFD) simulations
A “credible” computational fluid dynamics (CFD) model has the potential to provide a meaningful evaluation of safety in medical devices. One major challenge in establishing “model credibility” is to determine the required degree of similarity between the model and experimental results for the model…
-
Artikel Jurnal Teks lengkap
Thrombogenic Risk Assessment of Transcatheter Prosthetic Heart Valves Using a Fluid-Structure Interaction Approach
BACKGROUND AND OBJECTIVE: Prosthetic heart valve interventions such as TAVR have surged over the past decade, but the associated complication of long-term, life-threatening thrombotic events continues to undermine patient outcomes. Thus, improving thrombogenic risk analysis of TAVR devices is…
-
Artikel Jurnal Teks lengkap
Numerical Model of Full Cardiac Cycle Hemodynamics in a Total Artificial Heart and the Effect of Its Size on Platelet Activation
The SynCardia total artificial heart (TAH) is the only FDA approved device for replacing hearts in patients with congestive heart failure. It pumps blood via pneumatically driven diaphragms and controls the flow with mechanical valves. While it has been successfully implanted in more than 1,300…
-
Artikel Jurnal Teks lengkap
A rubric for assessing conformance to the Ten Rules for credible practice of modeling and simulation in healthcare
The power of computational modeling and simulation (M&S) is realized when the results are credible, and the workflow generates evidence that supports credibility for the context of use. The Committee on Credible Practice of Modeling & Simulation in Healthcare was established to help address the…
-
Artikel Jurnal Teks lengkap
Credibility, Replicability, and Reproducibility in Simulation for Biomedicine and Clinical Applications in Neuroscience
Modeling and simulation in computational neuroscience is currently a research enterprise to better understand neural systems. It is not yet directly applicable to the problems of patients with brain disease. To be used for clinical applications, there must not only be considerable progress in the…
-
Artikel Jurnal Teks lengkap
Towards Estimating the Uncertainty Associated with Three-Dimensional Geometry Reconstructed from Medical Image Data
Patient-specific computational modeling is increasingly used to assist with visualization, planning, and execution of medical treatments. This trend is placing more reliance on medical imaging to provide accurate representations of anatomical structures. Digital image analysis is used to extract…
-
Artikel Jurnal Teks lengkap
An in silico testbed for fast and accurate MR labeling of orthopedic implants
One limitation on the ability to monitor health in older adults using magnetic resonance (MR) imaging is the presence of implants, where the prevalence of implantable devices (orthopedic, cardiac, neuromodulation) increases in the population, as does the pervasiveness of conditions requiring MRI…
-
Artikel Jurnal Teks lengkap
An In-Silico Testbed for Fast and Accurate MR Labeling of Orthopaedic Implants
One limitation on the ability to monitor health in older adults using Magnetic Resonance (MR) imaging is the presence of implants, where the prevalence of implantable devices (orthopedic, cardiac, neuromodulation) increases in the population, as does the pervasiveness of conditions requiring MRI…
-
Artikel Jurnal Teks lengkap
Credible practice of modeling and simulation in healthcare: ten rules from a multidisciplinary perspective
The complexities of modern biomedicine are rapidly increasing. Thus, modeling and simulation have become increasingly important as a strategy to understand and predict the trajectory of pathophysiology, disease genesis, and disease spread in support of clinical and policy decisions. In such cases…