105 hasil untuk "Johnson Francis"
Menampilkan 1–20 · 0,42 detik · RSS
-
Artikel Jurnal
Electromagnetic Interference in Implantable Rhythm Devices - The Indian Scenario
Implantable rhythm device (IRD) is the generic name for the group of implantable devices used for diagnosis and treatment of cardiac arrhythmias. Devices in this category include cardiac pacemakers, implantable cardioverter defibrillators and implantable loop recorders. Since these devices have…
-
Artikel Jurnal
Role of Adenosine/ATP Test in Supraventricular Tachycardia
The successful treatment of paroxysmal supraventricular tachycardia with adenosine 5` triphosphate (ATP) was initially reported by Somlo1 in 1955. Sharma et al2 noted the value of intravenous ATP in the diagnosis and management of wide QRS complex tachycardia. ATP in incremental doses has been used…
-
Artikel Jurnal
ECG monitoring leads and special leads
ECG monitoring is common place in the hospital and even pre-hospital setting. The need for different types of lead systems in different settings has been emphasised. Simple three electrode bipolar recording is ubiquitous for monitoring. This can be used to record modified bipolar chest leads as…
-
Artikel Jurnal
Brugada-Like Electrocardiographic Pattern
The Brugada syndrome is characterized by a ST-segment elevation in the right precordial leads associated with right bundle branch block (RBBB) pattern and a propensity for life-threatening ventricular arrhythmias in the absence of structural heart disease.1 Mutations in a cardiac sodium channel…
-
Artikel Jurnal
Atrial Fibrillation and Hyperthyroidism
Atrial fibrillation occurs in 10 – 15% of patients with hyperthyroidism. Low serum thyrotropin concentration is an independent risk factor for atrial fibrillation. Thyroid hormone contributes to arrythmogenic activity by altering the electrophysiological characteristics of atrial myocytes by…
-
Artikel Jurnal
Interference Between Cellular Telephones and Implantable Rhythm Devices: A Review on Recent Papers
Background: Cardiac pacemakers and implantable defibrillators are potentially susceptible to electromagnetic interferences as they have complex circuitry for sensing and communication purposes. Cellular telephones being an important source of electromagnetic waves are likely to cause interference…
-
Artikel Jurnal
N-terminal Pro-Brain Natriuretic Peptide And Atrial Fibrillation
NT-proBNP is produced from both atria and ventricles. The primary regulation of production is at the synthesis level. The plasma half-life of NT-proBNP is 60-120 min. Cutoff value of NT-proBNP for diagnosis of heart failure is 125 pg/ml in the age group below 75 years and 450 pg/ml in the age group…
-
Artikel Jurnal
Biological Pacemakers
Genetically engineered pacemakers could be a possible alternative to implantable electronic devices for the treatment of bradyarrhythmias. The strategies include upregulation of beta adrenergic receptors, conversion of myocytes into pacemaker cells and stem cell therapy. Pacemaker activity in adult…
-
Artikel Jurnal
Fragmented QRS – Its significance
Fragment QRS (fQRS) complex is a myocardial conduction abnormality that indicates myocardial scar. It is defined as additional notches in the QRS complex. Though initially fQRS was defined in the setting of normal QRS duration (
-
Artikel Jurnal
Atrial fibrillation in Cardiac Channelopathies
Atrial fibrillation is the commonest arrhythmia encountered in day-to-day clinical practice. Its prevalence is increasing due to increasing age of the population, increasing prevalence of chronic heart disease and better diagnostic techniques. It is an extremely costly public health problem. It…
-
Artikel Jurnal
Wearable cardioverter defibrillator: A life vest till the life boat (ICD) arrives
It is well established that implantable cardioverter defibrillator (ICD) is a life saving device ensuring protection against life threatening ventricular arrhythmias. But there are certain situations like a recent myocardial infarction where the standard guidelines do not recommend the implantation…
-
Artikel Jurnal
Role of Catheter Ablation in Arrhythmogenic Right Ventricular Dysplasia
Arrhythmogenic right ventricular dysplasia/cardiomyopathy is a disorder characterized by frequent ventricular tachycardia originating from the right ventricle and fibro-fatty replacement of right ventricular myocardium. Though the disorder was originally described during surgical ablation of…
-
Artikel Jurnal
Congenital Short QT Syndrome
Long QT intervals in the ECG have long been associated with sudden cardiac death. The congenital long QT syndrome was first described in individuals with structurally normal hearts in 1957.1 Little was known about the significance of a short QT interval. In 1993, after analyzing 6693 consecutive…
-
Artikel Jurnal
Dual Ventricular Response or 1 : 2 Atrioventricular Conduction in Dual Atrioventricular Nodal Physiology
Dual ventricular response to a single supraventricular impulse is an interesting possibility in the presence of dual atrioventricular nodal physiology. Double His bundle and ventricular responses to a single atrial impulse caused by a simultaneous fast and slow pathway conduction is the hallmark of…
-
Artikel Jurnal
Ventricular Arrhythmias in Hypertrophic Cardiomyopathy- Can We Ever Predict Them?
Hypertrophic cardiomyopathy (HCM) is characterized by gross cardiac and myocyte hypertrophy, myocyte disarray, and interstitial fibrosis. This condition is relatively common, with a prevalence of about 1:500 in the general population. Most patients with HCM are either asymptomatic or have only…