Biblio Discovery — Demo Discovery Service

22 hasil untuk "Ketcha, M"

Menampilkan 1–20 · 0,49 detik · RSS

  1. Artikel Jurnal Teks lengkap

    A Momentum-Based Diffeomorphic Demons Framework for Deformable MR-CT Image Registration

    Han, R.; De Silva, T.; Ketcha, M. dkk.

    Phys Med Biol · 2018 · Inggris · PubMed Central

    PURPOSE: Neuro-navigated procedures require a high degree of geometric accuracy but are subject to geometric error from complex deformation in the deep brain – e.g., regions about the ventricles due to egress of cerebrospinal fluid (CSF) upon neuroendoscopic approach or placement of a ventricular…

  2. Artikel Jurnal Teks lengkap

    Automatic Masking for Robust 3D-2D Image Registration in Image-Guided Spine Surgery

    Ketcha, M. D.; De Silva, T.; Uneri, A. dkk.

    Proc SPIE Int Soc Opt Eng · 2016 · Inggris · PubMed Central

    During spinal neurosurgery, patient-specific information, planning, and annotation such as vertebral labels can be mapped from preoperative 3D CT to intraoperative 2D radiographs via image-based 3D-2D registration. Such registration has been shown to provide a potentially valuable means of decision…

  3. Artikel Jurnal Teks lengkap

    Geometric Calibration Using Line Fiducials for Cone-Beam CT with General, Non-Circular Source-Detector Trajectories

    Jacobson, M.W.; Ketcha, M.; Uneri, A. dkk.

    Proc SPIE Int Soc Opt Eng · 2017 · Inggris · PubMed Central

    PURPOSE: Traditional BB-based geometric calibration methods for cone-beam CT (CBCT) rely strongly on foreknowledge of the scan trajectory shape. This is a hindrance to the implementation of variable trajectory CBCT systems, normally requiring a dedicated calibration phantom or software algorithm…

  4. Artikel Jurnal Teks lengkap

    A mobile isocentric C-arm for intraoperative cone-beam CT: Technical assessment of dose and 3D imaging performance

    Sheth, N. M.; De Silva, T.; Uneri, A. dkk.

    Med Phys · 2020 · Inggris · PubMed Central

    PURPOSE: To characterize the radiation dose and three-dimensional (3D) imaging performance of a recently developed mobile, isocentric C-arm equipped with a flat-panel detector (FPD) for intraoperative cone-beam computed tomography (CBCT) (Cios Spin 3D, Siemens Healthineers) and to identify…

  5. Artikel Jurnal Teks lengkap

    Atlas-based automatic planning and 3D–2D fluoroscopic guidance in pelvic trauma surgery

    Han, R; Uneri, A; De Silva, T dkk.

    Phys Med Biol · 2019 · Inggris · PubMed Central

    Percutaneous screw fixation in pelvic trauma surgery is a challenging procedure that often requires long fluoroscopic exposure times and trial-and-error insertion attempts along narrow bone corridors of the pelvis. We report a method to automatically plan surgical trajectories using preoperative CT…

  6. Artikel Jurnal Teks lengkap

    Fundamental limits of image registration performance: Effects of image noise and resolution in CT-guided interventions

    Ketcha, M. D.; de Silva, T.; Han, R. dkk.

    Proc SPIE Int Soc Opt Eng · 2017 · Inggris · PubMed Central

    PURPOSE: In image-guided procedures, image acquisition is often performed primarily for the task of geometrically registering information from another image dataset, rather than detection / visualization of a particular feature. While the ability to detect a particular feature in an image has been…

  7. Artikel Jurnal Teks lengkap

    Data-Driven Detection and Registration of Spine Surgery Instrumentation in Intraoperative Images

    Doerr, S. A.; Uneri, A.; Huang, Y. dkk.

    Proc SPIE Int Soc Opt Eng · 2020 · Inggris · PubMed Central

    PURPOSE. Conventional model-based 3D-2D registration algorithms can be challenged by limited capture range, model validity, and stringent intraoperative runtime requirements. In this work, a deep convolutional neural network was used to provide robust initialization of a registration algorithm…

  8. Artikel Jurnal Teks lengkap

    Multi-Stage 3D-2D Registration for Correction of Anatomical Deformation in Image-Guided Spine Surgery

    Ketcha, M D; De Silva, T; Uneri, A dkk.

    Phys Med Biol · 2017 · Inggris · PubMed Central

    PURPOSE: A multi-stage image-based 3D-2D registration method is presented that maps annotations in a 3D image (e.g., point labels annotating individual vertebrae in preoperative CT) to an intraoperative radiograph in which the patient has undergone non-rigid anatomical deformation due to changes in…

  9. Artikel Jurnal Teks lengkap

    Automatic pedicle screw planning using atlas-based registration of anatomy and reference trajectories

    Vijayan, R; De Silva, T; Han, R dkk.

    Phys Med Biol · 2019 · Inggris · PubMed Central

    An algorithm for automatic spinal pedicle screw planning is reported and evaluated in simulation and first clinical studies. A statistical atlas of the lumbar spine (N = 40 members) was constructed for active shape model (ASM) registration of target vertebrae to an unsegmented patient CT. The atlas…

  10. Artikel Jurnal Teks lengkap

    Deformable 3D-2D Registration for Guiding K-Wire Placement in Pelvic Trauma Surgery

    Goerres, J.; Jacobson, M.; Uneri, A. dkk.

    Proc SPIE Int Soc Opt Eng · 2017 · Inggris · PubMed Central

    Pelvic Kirschner wire (K-wire) insertion is a challenging surgical task requiring interpretation of complex 3D anatomical shape from 2D projections (fluoroscopy) and delivery of device trajectories within fairly narrow bone corridors in proximity to adjacent nerves and vessels. Over long…

  11. Artikel Jurnal Teks lengkap

    Multi-body 3D–2D registration for image-guided reduction of pelvic dislocation in orthopaedic trauma surgery

    Han, R; Uneri, A; Ketcha, M dkk.

    Phys Med Biol · 2020 · Inggris · PubMed Central

    Surgical reduction of pelvic dislocation is a challenging procedure with poor long-term prognosis if reduction does not accurately restore natural morphology. The procedure often requires long fluoroscopic exposure times and trial-and-error to achieve accurate reduction. We report a method to…

  12. Artikel Jurnal Teks lengkap

    Spinal pedicle screw planning using deformable atlas registration

    Goerres, J.; Uneri, A.; De Silva, T. dkk.

    Phys Med Biol · 2017 · Inggris · PubMed Central

    Spinal screw placement is a challenging task due to small bone corridors and high risk of neurological or vascular complications, benefiting from precision guidance / navigation and quality assurance (QA). Implicit to both guidance and QA is the definition of a surgical plan – i.e., the desired…

  13. Artikel Jurnal Teks lengkap

    3D–2D image registration for target localization in spine surgery: investigation of similarity metrics providing robustness to content mismatch

    De Silva, T; Uneri, A; Ketcha, M D dkk.

    Phys Med Biol · 2016 · Inggris · PubMed Central

    In image-guided spine surgery, robust three-dimensional to two-dimensional (3D–2D) registration of preoperative computed tomography (CT) and intraoperative radiographs can be challenged by the image content mismatch associated with the presence of surgical instrumentation and implants as well as…

  14. Artikel Jurnal Teks lengkap

    Data-Driven Deformable 3D-2D Registration for Guiding Neuroelectrode Placement in Deep Brain Stimulation

    Uneri, A.; Wu, P.; Jones, C. K. dkk.

    Proc SPIE Int Soc Opt Eng · 2021 · Inggris · PubMed Central

    PURPOSE. Deep brain stimulation is a neurosurgical procedure used in treatment of a growing spectrum of movement disorders. Inaccuracies in electrode placement, however, can result in poor symptom control or adverse effects and confound variability in clinical outcomes. A deformable 3D-2D…

  15. Artikel Jurnal Teks lengkap

    Real-Time, Image-Based Slice-to-Volume Registration for Ultrasound-Guided Spinal Intervention

    De Silva, T.; Uneri, A.; Zhang, X. dkk.

    Phys Med Biol · 2018 · Inggris · PubMed Central

    PURPOSE: Real-time fusion of magnetic resonance (MR) and ultrasound (US) images could facilitate safe and accurate needle placement in spinal interventions. We develop an entirely image-based registration method (independent of or complementary to surgical trackers) that includes an efficient US…

  16. Artikel Jurnal Teks lengkap

    Image-Guided Robotic K-Wire Placement for Orthopaedic Trauma Surgery

    Vijayan, R. C.; Han, R.; Wu, P. dkk.

    Proc SPIE Int Soc Opt Eng · 2020 · Inggris · PubMed Central

    PURPOSE. We report the initial development of an image-based solution for robotic assistance of pelvic fracture fixation. The approach uses intraoperative radiographs, preoperative CT, and an end effector of known design to align the robot with target trajectories in CT. The method extends previous…

  17. Artikel Jurnal Teks lengkap

    Planning, Guidance, and Quality Assurance of Pelvic Screw Placement Using Deformable Image Registration

    Goerres, J.; Uneri, A.; Jacobson, M. dkk.

    Phys Med Biol · 2017 · Inggris · PubMed Central

    Percutaneous pelvic screw placement is challenging due to narrow bone corridors surrounded by vulnerable structures and difficult visual interpretation of complex anatomical shapes in 2D x-ray projection images. To address these challenges, a system for planning, guidance, and quality assurance…

  18. Artikel Jurnal Teks lengkap

    Registration of MRI to Intraoperative Radiographs for Target Localization in Spinal Interventions

    De Silva, T; Uneri, A; Ketcha, M D dkk.

    Phys Med Biol · 2017 · Inggris · PubMed Central

    PURPOSE: Decision support to assist in target vertebra localization could provide a useful aid to safe and effective spine surgery. Previous solutions have shown 3D-2D registration of preoperative CT to intraoperative radiographs to reliably annotate vertebral labels for assistance during level…

  19. Artikel Jurnal Teks lengkap

    Performance Evaluation of MIND Demons Deformable Registration of MR and CT Images in Spinal Interventions

    Reaungamornrat, S.; De Silva, T.; Uneri, A. dkk.

    Phys Med Biol · 2016 · Inggris · PubMed Central

    Accurate intraoperative localization of target anatomy and adjacent nervous and vascular tissue is essential to safe, effective surgery, and multimodality deformable registration can be used to identify such anatomy by fusing preoperative CT or MR images with intraoperative images. A deformable…

  20. Artikel Jurnal Teks lengkap

    C-arm Positioning Using Virtual Fluoroscopy for Image-Guided Surgery

    De Silva, T.; Punnoose, J.; Uneri, A. dkk.

    Proc SPIE Int Soc Opt Eng · 2017 · Inggris · PubMed Central

    INTRODUCTION: Fluoroscopically guided procedures often involve repeated acquisitions for C-arm positioning at the cost of radiation exposure and time in the operating room. A virtual fluoroscopy system is reported with the potential of reducing dose and time spent in C-arm positioning, utilizing…