25 hasil untuk "Knott, Kristopher D."
Menampilkan 1–20 · 0,43 detik · RSS
-
Artikel Jurnal Teks lengkap
CMR is vital in the management of cardiology inpatients: a tertiary centre experience
To review the utility of cardiovascular magnetic resonance (CMR) in the management of hospital inpatients, we performed a retrospective review of all inpatient CMR scans performed over a six-month period at a tertiary referral cardiology centre. Patient demographics, indication for CMR imaging…
-
Artikel Jurnal Teks lengkap
Automated Detection of Left Ventricle in Arterial Input Function Images for Inline Perfusion Mapping using Deep Learning: A study of 15,000 Patients
PURPOSE: Quantification of myocardial perfusion has the potential to improve the detection of regional and global flow reduction. Significant effort has been made to automate the workflow, where one essential step is the arterial input function (AIF) extraction. Failure to accurately identify the…
-
Artikel Jurnal Teks lengkap
Automated Inline Analysis of Myocardial Perfusion MRI with Deep Learning
PURPOSE: To develop a deep neural network–based computational workflow for inline myocardial perfusion analysis that automatically delineates the myocardium, which improves the clinical workflow and offers a “one-click” solution. MATERIALS AND METHODS: In this retrospective study, consecutive…
-
Artikel Jurnal Teks lengkap
Saturation-pulse prepared heart-rate independent inversion-recovery (SAPPHIRE) biventricular T1 mapping: inter-field strength, head-to-head comparison of diastolic, systolic and dark-blood measurements
BACKGROUND: To assess the feasibility of biventricular SAPPHIRE T(1) mapping in vivo across field strengths using diastolic, systolic and dark-blood (DB) approaches. METHODS: 10 healthy volunteers underwent same-day non-contrast cardiovascular magnetic resonance at 1.5 Tesla (T) and 3 T. Left and…
-
Artikel Jurnal Teks lengkap
Non-invasive Ischaemia Testing in Patients With Prior Coronary Artery Bypass Graft Surgery: Technical Challenges, Limitations, and Future Directions
Coronary artery bypass graft (CABG) surgery effectively relieves symptoms and improves outcomes. However, patients undergoing CABG surgery typically have advanced coronary atherosclerotic disease and remain at high risk for symptom recurrence and adverse events. Functional non-invasive testing for…
-
Artikel Jurnal Teks lengkap
Myocardial Storage, Inflammation, and Cardiac Phenotype in Fabry Disease After One Year of Enzyme Replacement Therapy
Cardiac response to enzyme replacement therapy (ERT) in Fabry disease is typically assessed by measuring left ventricular mass index using echocardiography or cardiovascular magnetic resonance, but neither quantifies myocardial biology. Low native T1 in Fabry disease represents sphingolipid…
-
Artikel Jurnal Teks lengkap
Measurement of T1 Mapping in Patients With Cardiac Devices: Off-Resonance Error Extends Beyond Visual Artifact but Can Be Quantified and Corrected
Background: Measurement of myocardial T1 is increasingly incorporated into standard cardiovascular magnetic resonance (CMR) protocols, however accuracy may be reduced in patients with metallic cardiovascular implants. Measurement is feasible in segments free from visual artifact, but there may…
-
Artikel Jurnal Teks lengkap
Quantitative Myocardial Perfusion in Fabry Disease
BACKGROUND: Fabry disease (FD) is an X-linked lysosomal storage disease resulting in tissue accumulation of sphingolipids. Key myocardial processes that lead to adverse outcomes in FD include storage, hypertrophy, inflammation, and fibrosis. These are quantifiable by multiparametric cardiovascular…
-
Artikel Jurnal Teks lengkap
Quantitative myocardial perfusion in coronary artery disease: A perfusion mapping study
BACKGROUND: Cardiac MR stress perfusion remains a qualitative technique in clinical practice due to technical and postprocessing challenges. However, automated inline perfusion mapping now permits myocardial blood flow (MBF, ml/g/min) quantification on‐the‐fly without user input. PURPOSE: To…
-
Artikel Jurnal Teks lengkap
A comparison of standard and high dose adenosine protocols in routine vasodilator stress cardiovascular magnetic resonance: dosage affects hyperaemic myocardial blood flow in patients with severe left ventricular systolic impairment
BACKGROUND: Adenosine stress perfusion cardiovascular magnetic resonance (CMR) is commonly used in the assessment of patients with suspected ischaemia. Accepted protocols recommend administration of adenosine at a dose of 140 µg/kg/min increased up to 210 µg/kg/min if required. Conventionally…
-
Artikel Jurnal Teks lengkap
Quantitative cardiovascular magnetic resonance myocardial perfusion mapping to assess hyperaemic response to adenosine stress
AIMS: Assessment of hyperaemia during adenosine stress cardiovascular magnetic resonance (CMR) remains a clinical challenge with lack of a gold-standard non-invasive clinical marker to confirm hyperaemic response. This study aimed to validate maximum stress myocardial blood flow (SMBF) measured…
-
Artikel Jurnal Teks lengkap
Quality assurance of late gadolinium enhancement cardiac magnetic resonance images: a deep learning classifier for confidence in the presence or absence of abnormality with potential to prompt real-time image optimization
BACKGROUND: Late gadolinium enhancement (LGE) of the myocardium has significant diagnostic and prognostic implications, with even small areas of enhancement being important. Distinguishing between definitely normal and definitely abnormal LGE images is usually straightforward, but diagnostic…
-
Artikel Jurnal Teks lengkap
Use of quantitative cardiovascular magnetic resonance myocardial perfusion mapping for characterization of ischemia in patients with left internal mammary coronary artery bypass grafts
BACKGROUND: Quantitative myocardial perfusion mapping using cardiovascular magnetic resonance (CMR) is validated for myocardial blood flow (MBF) estimation in native vessel coronary artery disease (CAD). Following coronary artery bypass graft (CABG) surgery, perfusion defects are often detected in…
-
Artikel Jurnal Teks lengkap
Prognostic Value of Pulmonary Transit Time and Pulmonary Blood Volume Estimation Using Myocardial Perfusion CMR
OBJECTIVES: The purpose of this study was to explore the prognostic significance of PTT and PBVi using an automated, inline method of estimation using CMR. BACKGROUND: Pulmonary transit time (PTT) and pulmonary blood volume index (PBVi) (the product of PTT and cardiac index), are quantitative…
-
Artikel Jurnal Teks lengkap
Quantitative Myocardial Perfusion Predicts Outcomes in Patients with Prior Surgical Revascularization
BACKGROUND: Patients with prior coronary artery bypass graft (CABG) surgery typically have complex coronary disease and remain at high risk of adverse events. Quantitative myocardial perfusion indices predict outcomes in native vessel disease, but their prognostic performance in patients with prior…
-
Artikel Jurnal Teks lengkap
Two-Minute k-Space and Time–accelerated Aortic Four-dimensional Flow MRI: Dual-Center Study of Feasibility and Impact on Velocity and Wall Shear Stress Quantification
PURPOSE: To investigate the two-center feasibility of highly k-space and time (k-t)–accelerated 2-minute aortic four-dimensional (4D) flow MRI and to evaluate its performance for the quantification of velocities and wall shear stress (WSS). MATERIALS AND METHODS: This cross-sectional study…
-
Artikel Jurnal Teks lengkap
The Prognostic Significance of Quantitative Myocardial Perfusion
BACKGROUND: Myocardial perfusion reflects the macro- and microvascular coronary circulation. Recent quantitation developments using cardiovascular magnetic resonance perfusion permit automated measurement clinically. We explored the prognostic significance of stress myocardial blood flow (MBF) and…
-
Artikel Jurnal Teks lengkap
Inline perfusion mapping provides insights into the disease mechanism in hypertrophic cardiomyopathy
OBJECTIVE: In patients with hypertrophic cardiomyopathy (HCM), the role of small vessel disease and myocardial perfusion remains incompletely understood and data on absolute myocardial blood flow (MBF, mL/g/min) are scarce. We measured MBF using cardiovascular magnetic resonance fully quantitative…