Biblio Discovery — Demo Discovery Service

23 hasil untuk "Max Denis"

Menampilkan 1–20 · 0,46 detik · RSS

  1. Artikel Jurnal

    ML-ECG-COVID: A Machine Learning-Electrocardiogram Signal Processing Technique for COVID-19 Predictive Modeling

    John Irungu; Timothy Oladunni; Andrew C. Grizzle dkk.

    IEEE Access, Vol. 11 · 2023 · Inggris · DOAJ Scopus

    Since the outbreak of coronavirus also known as COVID-19, there have been several studies on the disease. This study investigates patients’ electrocardiography (ECG) properties for an accurate prediction of this infectious disease. Our findings will be useful to medical practitioners in the…

  2. Artikel Jurnal Teks lengkap

    Effect of Calcifications on Breast Ultrasound Shear Wave Elastography: An Investigational Study

    Adriana Gregory; Mohammad Mehrmohammadi; Max Denis dkk.

    PLOS ONE, Vol. 10 No. 9 · 2015 · Inggris · PLOS Scopus

    Purpose: To investigate the effects of macrocalcifications and clustered microcalcifications associated with benign breast masses on shear wave elastography (SWE). Methods: SuperSonic Imagine (SSI) and comb-push ultrasound shear elastography (CUSE) were performed on three sets of phantoms to…

    Juga tersedia di: DOAJ

  3. Artikel Jurnal Teks lengkap

    Viscoelastic parameters as discriminators of breast masses: Initial human study results

    Viksit Kumar; Max Denis; Adriana Gregory dkk.

    PLOS ONE, Vol. 13 No. 10 · 2018 · Inggris · PLOS Scopus

    Shear wave elastography is emerging as a clinically valuable diagnostic tool to differentiate between benign and malignant breast masses. Elastography techniques assume that soft tissue can be modelled as a purely elastic medium. However, this assumption is often violated as soft tissue exhibits…

    Juga tersedia di: DOAJ

  4. Artikel Jurnal Teks lengkap

    Diagnostic features of quantitative comb-push shear elastography for breast lesion differentiation

    Mahdi Bayat; Max Denis; Adriana Gregory dkk.

    PLOS ONE, Vol. 12 No. 3 · 2017 · Inggris · PLOS Scopus

    Background: Lesion stiffness measured by shear wave elastography has shown to effectively separate benign from malignant breast masses. The aim of this study was to evaluate different aspects of Comb-push Ultrasound Shear Elastography (CUSE) performance in differentiating breast masses. Methods…

    Juga tersedia di: DOAJ

  5. Artikel Jurnal Teks lengkap

    Noninvasive Evaluation of Bladder Wall Mechanical Properties as a Function of Filling Volume: Potential Application in Bladder Compliance Assessment

    Ivan Nenadic; Lance Mynderse; Douglas Husmann dkk.

    PLOS ONE, Vol. 11 No. 6 · 2016 · Inggris · PLOS Scopus

    Purpose: We propose a novel method to monitor bladder wall mechanical properties as a function of filling volume, with the potential application to bladder compliance assessment. The proposed ultrasound bladder vibrometry (UBV) method uses ultrasound to excite and track Lamb waves on the bladder…

    Juga tersedia di: DOAJ

  6. Artikel Jurnal Teks lengkap

    Correlating Tumor Stiffness with Immunohistochemical Subtypes of Breast Cancers: Prognostic Value of Comb-Push Ultrasound Shear Elastography for Differentiating Luminal Subtypes

    Max Denis; Adriana Gregory; Mahdi Bayat dkk.

    PLOS ONE, Vol. 11 No. 10 · 2016 · Inggris · PLOS Scopus

    Purpose: The purpose of our study is to correlate quantitatively measured tumor stiffness with immunohistochemical (IHC) subtypes of breast cancer. Additionally, the influence of prognostic histologic features (cancer grade, size, lymph node status, and histological type and grade) to the tumor…

    Juga tersedia di: DOAJ

  7. Artikel Jurnal Teks lengkap

    Automated and real-time segmentation of suspicious breast masses using convolutional neural network

    Viksit Kumar; Jeremy M. Webb; Adriana Gregory dkk.

    PLOS ONE, Vol. 13 No. 5 · 2018 · Inggris · PLOS Scopus

    In this work, a computer-aided tool for detection was developed to segment breast masses from clinical ultrasound (US) scans. The underlying Multi U-net algorithm is based on convolutional neural networks. Under the Mayo Clinic Institutional Review Board protocol, a prospective study of the…

    Juga tersedia di: DOAJ

  8. Artikel Jurnal Teks lengkap

    Correlation of ultrasound bladder vibrometry assessment of bladder compliance with urodynamic study results

    Mahdi Bayat; Viksit Kumar; Max Denis dkk.

    PLOS ONE, Vol. 12 No. 6 · 2017 · Inggris · PLOS Scopus

    Purpose or objective: The objective of this study is to assess correlation between bladder wall mechanical properties obtained by ultrasound bladder vibrometry (UBV) and urodynamic study (UDS) measurements in a group of patients undergoing clinical UDS procedure. Materials and methods: Concurrent…

    Juga tersedia di: DOAJ

  9. Artikel Jurnal Teks lengkap

    Comb-Push Ultrasound Shear Elastography of Breast Masses: Initial Results Show Promise

    Max Denis; Mohammad Mehrmohammadi; Pengfei Song dkk.

    PLOS ONE, Vol. 10 No. 3 · 2015 · Inggris · PLOS Scopus

    Purpose or Objective: To evaluate the performance of Comb-push Ultrasound Shear Elastography (CUSE) for classification of breast masses. Materials and Methods: CUSE is an ultrasound-based quantitative two-dimensional shear wave elasticity imaging technique, which utilizes multiple laterally…

    Juga tersedia di: DOAJ

  10. Artikel Jurnal Teks lengkap

    Ultrasound Radiation Force for the Assessment of Bone Fracture Healing in Children: An In Vivo Pilot Study

    Siavash Ghavami; Adriana Gregory; Jeremy Webb dkk.

    Sensors, Vol. 19 No. 4 · 2019 · Inggris · DOAJ Scopus

    Vibrational characteristics of bone are directly dependent on its physical properties. In this study, a vibrational method for bone evaluation is introduced. We propose a new type of quantitative vibro-acoustic method based on the acoustic radiation force of ultrasound for bone characterization in…