6 results for "Maximilian Fuetterer"
Showing 1–6 · 0.50 seconds · RSS
-
Journal Article
Impact of late gadolinium enhancement image acquisition resolution on neural network based automatic scar segmentation
Background: Automatic myocardial scar segmentation from late gadolinium enhancement (LGE) images using neural networks promises an alternative to time-consuming and observer-dependent semi-automatic approaches. However, alterations in data acquisition, reconstruction as well as post-processing may…
-
Journal Article
Hyperpolarized 13C urea myocardial first-pass perfusion imaging using velocity-selective excitation
Abstract Background A velocity-selective binomial excitation scheme for myocardial first-pass perfusion measurements with hyperpolarized 13C substrates, which preserves bolus magnetization inside the blood pool, is presented. The proposed method is evaluated against gadolinium-enhanced 1H…
-
Journal Article
Quantitative myocardial first-pass cardiovascular magnetic resonance perfusion imaging using hyperpolarized [1-13C] pyruvate
Abstract Background The feasibility of absolute myocardial blood flow quantification and suitability of hyperpolarized [1-13C] pyruvate as contrast agent for first-pass cardiovascular magnetic resonance (CMR) perfusion measurements are investigated with simulations and demonstrated in vivo in a…
-
Journal Article
Myocardial triglycerides in cardiac amyloidosis assessed by proton cardiovascular magnetic resonance spectroscopy
Abstract Background Cardiac involvement of amyloidosis leads to left-ventricular (LV) wall thickening with progressive heart failure requiring rehospitalization. Cardiovascular magnetic resonance (CMR) is a valuable tool to non-invasively assess myocardial thickening as well as structural changes…
-
Journal Article
Cardiovascular magnetic resonance imaging of functional and microstructural changes of the heart in a longitudinal pig model of acute to chronic myocardial infarction
Abstract Background We examined the dynamic response of the myocardium to infarction in a longitudinal porcine study using relaxometry, functional as well as diffusion cardiovascular magnetic resonance (CMR). We sought to compare non contrast CMR methods like relaxometry and in-vivo diffusion to…
-
Journal Article
Splenic switch-off in three-dimensional adenosine stress cardiac magnetic resonance perfusion for differentiating true-negative from potentially false-negative studies identified by fractional flow reserve
Background: False-negative cardiovascular magnetic resonance (CMR) perfusion results may arise from inadequate stress responses, even when patients exhibit an adequate clinical or heart-rate response to adenosine. This study aimed to explore the ability of qualitative and quantitative splenic…