56 hasil untuk "Pinilla, Isabel"
Menampilkan 1–20 · 0,27 detik · RSS
-
Artikel Jurnal Teks lengkap
Oxidative Stress as a Main Contributor of Retinal Degenerative Diseases
-
Artikel Jurnal Teks lengkap
Comparison of Retinal Nerve Fiber Layer Thickness Measurements in Healthy Subjects Using Fourier and Time Domain Optical Coherence Tomography
Purpose. To compare the retinal nerve fiber layer (RNFL) measurements using two different ocular coherence tomography (OCT) devices: Cirrus Fourier domain OCT and Stratus time domain OCT. To analyze reproducibility of Fourier domain measurements in healthy subjects. Methods. One hundred and…
-
Artikel Jurnal Teks lengkap
Preservation of outer retina and its synaptic connectivity following subretinal injections of human RPE cells in the Royal College of Surgeons rat
We have examined how transplantation of an RPE cell line to the subretinal space of RCS rats affects the distribution of synaptic connectivity markers in the outer plexiform layer of the retina. Using markers of pre- and post-synaptic profiles (bassoon and synaptophysin as presynaptic markers and…
-
Artikel Jurnal Teks lengkap
Retinal Vascular Degeneration in the Transgenic P23H Rat Model of Retinitis Pigmentosa
Retinitis pigmentosa (RP) is a group of inherited retinal degenerative diseases involving a progressive degeneration of photoreceptor cells. Following the loss of photoreceptors, retinal vascularization tends to decrease, which seems to play a role in the degenerative process of retinal cells. This…
-
Artikel Jurnal Teks lengkap
Astrocytes and Müller Cell Alterations During Retinal Degeneration in a Transgenic Rat Model of Retinitis Pigmentosa
Purpose: Retinitis pigmentosa includes a group of progressive retinal degenerative diseases that affect the structure and function of photoreceptors. Secondarily to the loss of photoreceptors, there is a reduction in retinal vascularization, which seems to influence the cellular degenerative…
-
Artikel Jurnal Teks lengkap
The Mydriasis-Free Handheld ERG Device and Its Utility in Clinical Practice: A Review
Background: Full field electroretinography (ERG) is an essential tool for assessing retinal function and diagnosing retinal diseases. In recent years, mydriasis-free handheld ERG devices have emerged as portable, non-invasive alternatives to traditional ERG systems. Their main application has been…
-
Artikel Jurnal Teks lengkap
Comparison of Anterior Segment Measurements Obtained by Three Different Devices in Healthy Eyes
Purpose. To assess the normal values and the repeatability of the Galilei Dual Scheimpflug Analyzer (GDSA), the biometer IOL Master, and the autokerato/refractometer WAM 5500 in anterior segment examinations. Methods. Eighty-eight eyes from 88 healthy volunteers were prospectively and consecutively…
-
Artikel Jurnal Teks lengkap
Evaluation of Macular Thickness Changes after Uncomplicated Phacoemulsification Surgery in Healthy Subjects and Diabetic Patients without Retinopathy by Spectral Domain OCT
Purpose: To assess differences in the evolution of macular thickness after uncomplicated phacoemulsification surgery between non-diabetic subjects and patients with diabetes mellitus (DM) without diabetic retinopathy (DR), using Spectral Domain OCT (SD-OCT). Methods: We performed a unicentric…
-
Artikel Jurnal Teks lengkap
Induced pluripotent stem cells as custom therapeutics for retinal repair: Progress and rationale
Human pluripotent stem cells have made a remarkable impact on science, technology and medicine by providing a potentially unlimited source of human cells for basic research and clinical applications. In recent years, knowledge gained from the study of human embryonic stem cells and mammalian…
-
Artikel Jurnal Teks lengkap
Speckle Contrast as Retinal Tissue Integrity Biomarker in Patients with Type 1 Diabetes Mellitus with No Retinopathy
Purpose: To study the retinal and choroidal layers in type 1 diabetes mellitus (DM1) without diabetic retinopathy (DR), using speckle contrast of optical coherence tomography (OCT) images as a tissue biomarker in comparison with healthy subjects. Methods: OCT Spectralis images of 148 eyes, 84 from…
-
Artikel Jurnal Teks lengkap
Safranal, a Saffron Constituent, Attenuates Retinal Degeneration in P23H Rats
Saffron, an extract from Crocus sativus, has been largely used in traditional medicine for its antiapoptotic and anticarcinogenic properties. In this work, we investigate the effects of safranal, a component of saffron stigmas, in attenuating retinal degeneration in the P23H rat model of autosomal…
-
Artikel Jurnal Teks lengkap
Choroidal Changes of Long-Term Type 1 Diabetic Patients without Retinopathy
The aim of the study is to assess choroidal thickness (CT) and choroidal volume (CV) in 90 type 1 diabetes mellitus (DM1) patients with no diabetic retinopathy (DR) and 60 control eyes using spectral domain optical coherence tomography (SD-OCT) and swept source (SS)-OCT in the areas of the Early…
-
Artikel Jurnal Teks lengkap
Epigallocatechin Gallate Slows Retinal Degeneration, Reduces Oxidative Damage, and Modifies Circadian Rhythms in P23H Rats
Retinitis pigmentosa (RP) includes a group of genetic disorders that involve the loss of visual function due to mutations mainly in photoreceptors but also in other retinal cells. Apoptosis, retinal disorganization, and inflammation are common in the progression of the disease. Epigallocatechin…
-
Artikel Jurnal Teks lengkap
Ocular manifestations in Okihiro Syndrome
BACKGROUND AND PURPOSE: Two siblings diagnosed with Okihiro syndrome (also named Duane Radial Ray Syndrome) associated with ophthalmic manifestation including Duane syndrome and retinal nerve fiber layer (RNFL) hypoplasia were presented. METHODS: The first patient (15-years old female) was…
-
Artikel Jurnal Teks lengkap
Repeatability of Ocular Measurements with a Dual-Scheimpflug Analyzer in Healthy Eyes
Purpose. To assess the repeatability of the Galilei dual Scheimpflug analyzer (GDSA) in anterior segment examination. Methods. Fifty-two eyes from 52 healthy volunteers were prospectively and consecutively recruited. Anatomic, axial, refractive, and instantaneous parameters were measured with GDSA…
-
Artikel Jurnal Teks lengkap
Evaluation of patient visual comfort and repeatability of refractive values in non-presbyopic healthy eyes
AIM: To evaluate the intra-operator repeatability in healthy subjects using the WAM-5500 auto-kerato/refractometer and the iTrace aberrometer, to compare the refractive values and the subjective refraction obtained with both devices and to determine which of these three spherocylindrical…
-
Artikel Jurnal Teks lengkap
A Reliable Criterion for the Correct Delimitation of the Foveal Avascular Zone in Diabetic Patients
Background: Manual segmentation of the Foveal Avascular Zone (FAZ) has a high level of variability. Research into retinas needs coherent segmentation sets with low variability. Methods: Retinal optical coherence tomography angiography (OCTA) images from type-1 diabetes mellitus (DM1), type-2…
-
Artikel Jurnal Teks lengkap
Reprogramming Müller glia via in vivo cell fusion regenerates murine photoreceptors
Vision impairments and blindness caused by retinitis pigmentosa result from severe neurodegeneration that leads to a loss of photoreceptors, the specialized light-sensitive neurons that enable vision. Although the mammalian nervous system is unable to replace neurons lost due to degeneration…
-
Artikel Jurnal Teks lengkap
Changes in retinal layers in type 1 diabetes mellitus without retinopathy measured by spectral domain and swept source OCTs
To evaluate changes in inner retinal layer (IRL) thicknesses in patients with type 1 diabetes mellitus (DM1) with no diabetic retinopathy (DR) using two different optical coherence tomography (OCT) devices. Ninety DM1 and 60 healthy eyes were evaluated using spectral domain (SD)-OCT and swept…
-
Artikel Jurnal Teks lengkap
Development of optokinetic tracking software for objective evaluation of visual function in rodents
The aim of this study was to develop software that performs the optokinetic tracking assessment without the involvement of experimenters to increase the objectivity of the test. To check the effectiveness of the software, several videos were analyzed and the results were compared to those produced…