59 hasil untuk "Prakash, Punit"
Menampilkan 1–20 · 1,56 detik · RSS
-
Artikel Jurnal Teks lengkap
Theoretical Modeling for Hepatic Microwave Ablation
Thermal tissue ablation is an interventional procedure increasingly being used for treatment of diverse medical conditions. Microwave ablation is emerging as an attractive modality for thermal therapy of large soft tissue targets in short periods of time, making it particularly suitable for…
-
Artikel Jurnal Teks lengkap
Quantitative assessment of thermal ablation in small animal tumor models: implications for pre-clinical studies of combination treatments
Background. Radiofrequency (RF) and other thermal ablation modalities in combination with systemic therapies are the subject of investigations for the treatment of tumors at risk of recurrence after first line therapies. The potential of combined therapeutic approaches is studied largely in small…
-
Artikel Jurnal Teks lengkap
Considerations for theoretical modeling of thermal ablation with catheter-based ultrasonic sources: implications for treatment planning, monitoring and control
PURPOSE: To determine the impact of including dynamic changes in tissue physical properties during heating on feedback controlled thermal ablation with catheter-based ultrasound. Additionally, we compared impact several indicators of thermal damage on predicted extents of ablation zones for…
-
Artikel Jurnal Teks lengkap
Broadband lung dielectric properties over the ablative temperature range: experimental measurements and parametric models
PURPOSE: Computational models of microwave tissue ablation are widely used to guide the development of ablation devices, and are increasingly being used for development of treatment planning and monitoring platforms. Knowledge of temperature dependent dielectric properties of lung tissue is…
-
Artikel Jurnal Teks lengkap
Broadband Dielectric Properties of Ex Vivo Bovine Liver Tissue Characterized at Ablative Temperatures
OBJECTIVE: To investigate the thermal and frequency dependence of dielectric properties of ex vivo liver tissue – relative permittivity and effective conductivity – over the frequency range of 500 MHz to 6 GHz and temperatures ranging from 20 to 130 °C. METHODS: We measured the dielectric…
-
Artikel Jurnal Teks lengkap
Simulation-based design and characterization of a microwave applicator for MR-guided hyperthermia experimental studies in small animals
PURPOSE: The objective of this study was to design and characterize a 2.45 GHz microwave hyperthermia applicator for delivering hyperthermia in experimental small animals to 2 – 4 mm diameter targets located 1 - 3 mm from the skin surface, with minimal heating of the surrounding tissue, under 14.1…
-
Artikel Jurnal Teks lengkap
A Computational Modeling Approach to Investigate the Influence of Hyperthermia on the Tumor Microenvironment
The biophysical properties of the tumor microenvironment differ substantially from normal tissues. A constellation of features, including decreased vascularity, lack of lymphatic drainage, and elevated interstitial pressure, diminishes the penetration of therapeutics into tumors. Local hyperthermia…
-
Artikel Jurnal Teks lengkap
Modeling of endoluminal and interstitial ultrasound hyperthermia and thermal ablation: applications to device design, feedback control, and treatment planning
Endoluminal and catheter-based ultrasound applicators are currently under development and are in clinical use for minimally invasive hyperthermia and thermal ablation of various tissue targets. Computational models play a critical role in in device design and optimization, assessment of therapeutic…
-
Artikel Jurnal Teks lengkap
Temperature superposition for fast computation of 3D temperature distributions during optimization and planning of interstitial ultrasound hyperthermia treatments
PURPOSE: A temperature superposition method has been developed for fast optimization and planning of interstitial hyperthermia treatments with convectively-cooled multi-transducer ultrasound applicators integrated within HDR brachytherapy catheters. METHODS: Steady-state temperature distributions…
-
Artikel Jurnal Teks lengkap
Experimental measurement of microwave ablation heating pattern and comparison to computer simulations
INTRODUCTION: For computational models of microwave ablation (MWA), knowledge of the antenna design is necessary, but the proprietary design of clinical applicators is often unknown. We characterized the specific absorption rate (SAR) during MWA experimentally and compared to a multi-physics…
-
Artikel Jurnal Teks lengkap
Experimental assessment of microwave ablation computational modeling with MR thermometry
PURPOSE: Computational models are widely used during the design and characterization of microwave ablation (MWA) devices, and have been proposed for pre-treatment planning. Our objective was to assess 3D transient temperature and ablation profiles predicted by MWA computational models with…
-
Artikel Jurnal Teks lengkap
A review of in vitro instrumentation platforms for evaluating thermal therapies in experimental cell culture models
Thermal therapies, the modulation of tissue temperature for therapeutic benefit, are in clinical use as adjuvant or stand-alone therapeutic modalities for a range of indications, and are under investigation for others. During delivery of thermal therapy in the clinic and in experimental settings…
-
Artikel Jurnal Teks lengkap
Multiple applicator hepatic ablation with interstitial ultrasound devices: Theoretical and experimental investigation
Purpose: To evaluate multiple applicator implant configurations of interstitial ultrasound devices for large volume ablation of liver tumors. Methods: A 3D bioacoustic-thermal model using the finite element method was implemented to assess multiple applicator implant configurations for thermal…
-
Artikel Jurnal Teks lengkap
Impact of Power and Time in Hepatic Microwave Ablation: Effect of Different Energy Delivery Schemes
Microwave ablation often involves the use of continuous energy-delivery protocols with a fixed power and time. To achieve larger ablation zones, a range of protocols and power levels have been studied in experimental studies. The objective of the present study was to develop and experimentally…
-
Artikel Jurnal Teks lengkap
Assessment of thermochromic phantoms for characterizing microwave ablation devices
BACKGROUND AND PURPOSE: Thermochromic gel phantoms provide a controlled medium for visual assessment of thermal ablation device performance. However, there are limited studies reporting on the comparative assessment of ablation profiles assessed in thermochromic gel phantoms against those in ex…
Juga tersedia di: PubMed Central
-
Artikel Jurnal Teks lengkap
A Novel Pipeline for Adrenal Gland Segmentation: Integration of a Hybrid Post-Processing Technique with Deep Learning
Accurate segmentation of adrenal glands from CT images is essential for enhancing computer-aided diagnosis and surgical planning. However, the small size, irregular shape, and proximity to surrounding tissues make this task highly challenging. This study introduces a novel pipeline that…
-
Artikel Jurnal Teks lengkap
Interstitial ultrasound ablation of vertebral and paraspinal tumours: Parametric and patient-specific simulations
PURPOSE: Theoretical parametric and patient-specific models are applied to assess the feasibility of interstitial ultrasound ablation of tumours in and near the spine and to identify potential treatment delivery strategies. METHODS: 3D patient-specific finite element models (n=11) of interstitial…
-
Artikel Jurnal Teks lengkap
Microwave ablation of lung tumors: A probabilistic approach for simulation-based treatment planning
PURPOSE: Microwave ablation (MWA) is a clinically established modality for treatment of lung tumors. A challenge with existing application of MWA, however, is local tumor progression, potentially due to failure to establish an adequate treatment margin. This study presents a robust simulation-based…
-
Artikel Jurnal Teks lengkap
How large is the periablational zone after radiofrequency and microwave ablation? Computer-based comparative study of two currently used clinical devices
PURPOSE: To compare the size of the coagulation (CZ) and periablational (PZ) zones created with two commercially available devices in clinical use for radiofrequency (RFA) and microwave ablation (MWA), respectively. METHODS: Computer models were used to simulate RFA with a 3-cm Cool-tip applicator…