27 hasil untuk "Ramak, Robbert"
Menampilkan 1–20 · 0,26 detik · RSS
-
Artikel Jurnal Teks lengkap
Compatibility assessment of a temperature-controlled radiofrequency catheter with a novel electroanatomical mapping system
BACKGROUND: The novel DiamondTemp ablation system (DTA) and EnSiteX mapping System (EAM) are both CE-Marked and FDA approved medical devices. The DTA has been validated by its manufacturer only in combination with previous version of EnSite System—EnSite Precision. The aim of this study was to…
-
Artikel Jurnal Teks lengkap
Development of a 3D printed surgical guide for Brugada syndrome substrate ablation
BACKGROUND: Brugada syndrome (BrS) is a disease associated with ventricular arrhythmias and sudden cardiac death. Epicardial ablation has demonstrated high therapeutic efficacy in preventing ventricular arrhythmias. The purpose of this research is to define a workflow to create a patient-specific…
-
Artikel Jurnal Teks lengkap
A 3D-printed surgical guide for ischemic scar targeting and ablation
BACKGROUND: 3D printing technology development in medical fields allows to create 3D models to assist preoperative planning and support surgical procedures. Cardiac ischemic scar is clinically associated with malignant arrhythmias. Catheter ablation is aimed at eliminating the arrhythmogenic tissue…
-
Artikel Jurnal Teks lengkap
Temperature analysis of 3D-printed biomaterials during unipolar and bipolar radiofrequency ablation procedure
BACKGROUND: Due to their mechanical properties, the MED625FLX and TPU95A could be appropriate candidates for cardiac 3D surgical guide use during radiofrequency ablation (RFA) treatment. METHODS: RFA aims to destroy the heart tissue, which cause arrhythmias, by applying a radiofrequency (RF) energy…
-
Artikel Jurnal Teks lengkap
3D Printed Surgical Guide for Coronary Artery Bypass Graft: Workflow from Computed Tomography to Prototype
Patient-specific three-dimensional (3D) printed models have been increasingly used in many medical fields, including cardiac surgery for which they are used as planning and communication tools. To locate and plan the correct region of interest for the bypass placement during coronary artery bypass…
-
Artikel Jurnal Teks lengkap
3D-Printed Biomaterial Testing in Response to Cryoablation: Implications for Surgical Ventricular Tachycardia Ablation
Background: The lack of thermally and mechanically performant biomaterials represents the major limit for 3D-printed surgical guides, aimed at facilitating complex surgery and ablations. Methods: Cryosurgery is a treatment for cardiac arrhythmias. It consists of obtaining cryolesions, by freezing…
-
Artikel Jurnal Teks lengkap
Evaluation of photogrammetry for medical application in cardiology
Background: In the field of medicine, photogrammetry has played for long time a marginal role due to the significant amount of work required that made it impractical for an extended medical use. Developments in digital photogrammetry occurred in the recent years, that have steadily increased the…
-
Artikel Jurnal Teks lengkap
Incremental value of left atrial strain to predict atrial fibrillation recurrence after cryoballoon ablation
OBJECTIVE: Atrial fibrillation (AF) recurrence occurs in approximately 25% of the patients undergoing cryoballoon ablation (CBA), leading to repeated ablations and complications. Left atrial (LA) dilation has been proposed as a predictor of AF recurrence. However, LA strain is a surrogate marker of…
-
Artikel Jurnal Teks lengkap
Universal Method of Compatibility Assessment for Novel Ablation Technologies With Different 3D Navigation Systems
BACKGROUND: New technologies for ablation procedures are often produced by different companies with no cross-compatibility out of the box. This is not a negligible clinical problem since those separately developed devices are often used together. The aim of this study was to develop a bench-testing…
-
Artikel Jurnal Teks lengkap
3D mapping challenges in hybrid video-assisted thoracoscopic surgical ablation of Brugada syndrome
OBJECTIVES: Brugada syndrome is a life-threatening disease with an arrhythmogenic substrate located in the epicardium of right ventricle outflow tract. Therefore, the correct region identification is crucial for a successful ablation procedure. Various mapping techniques can be adopted to elaborate…
-
Artikel Jurnal Teks lengkap
Development of a patient-specific epicardial guide for ventricular tachycardia ablation surgery using high-consistency rubber silicone molding
BACKGROUND: Concomitant epicardial ablation of ventricular tachycardia (VT) remains a clinical challenge in cardiac surgery due to the need for intra-operative mapping. A preoperative patient-tailored epicardial guide could provide an intraoperative ‘blueprint’ of arrhythmogenic target substrate…
-
Artikel Jurnal Teks lengkap
Outcomes of pulmonary vein isolation with radiofrequency balloon vs. cryoballoon ablation: a multi-centric study
AIMS: Cryoballoon (CB) ablation is the mainstay of single-shot pulmonary vein isolation (PVI). A radiofrequency balloon (RFB) catheter has recently emerged as an alternative. However, these two technologies have not been compared. This study aims to evaluate the freedom from atrial tachyarrhythmias…
-
Artikel Jurnal Teks lengkap
Procedural Safety and Efficacy for Pulmonary Vein Isolation with the Novel Polarx™ Cryoablation System: A Propensity Score Matched Comparison with the Arctic Front™ Cryoballoon in the Setting of Paroxysmal Atrial Fibrillation
BACKGROUND: The novel Polarx™ cryoablation system is currently being studied for atrial fibrillation (AF) ablation. To the best of our knowledge, no study comparing the novel cryoablation system with the standard Arctic Front™ cryoballoon is available in today’s literature. This study aims to…
-
Artikel Jurnal Teks lengkap
Novel noncontact charge density map in the setting of post-atrial fibrillation atrial tachycardias: first experience with the Acutus SuperMap Algorithm
PURPOSE: The purpose of this study was to evaluate the safety and feasibility of the new high-resolution mapping algorithm SuperMap (Acutus Medical, CA, USA) in identifying and guiding ablation in the setting of regular atrial tachycardias following index atrial fibrillation (AF) ablation. METHODS…
-
Artikel Jurnal Teks lengkap
Pulmonary vein isolation with the radiofrequency balloon catheter: a single centre prospective study
AIMS: The multielectrode radiofrequency balloon catheter (RFB) has been developed to achieve safe and effective pulmonary vein isolation (PVI) for atrial fibrillation (AF) ablation. This single-centre study aimed to evaluate the midterm clinical outcome and predictors of single-shot PVI with the…
-
Artikel Jurnal Teks lengkap
Atrial Fibrillation Global Changes after Pulmonary Vein and Posterior Wall Isolation: A Charge Density Mapping Study
Background: Non-contact charge density (CD) mapping allows a global visualization of left atrium (LA) activation and of activation patterns during atrial fibrillation (AF). The aim of this study was to analyze, with CD mapping, the changes in persistent AF induced by pulmonary vein isolation (PVI)…
-
Artikel Jurnal Teks lengkap
Advancing Surgical Arrhythmia Ablation: Novel Insights on 3D Printing Applications and Two Biocompatible Materials
To date, studies assessing the safety profile of 3D printing materials for application in cardiac ablation are sparse. Our aim is to evaluate the safety and feasibility of two biocompatible 3D printing materials, investigating their potential use for intra-procedural guides to navigate surgical…
-
Artikel Jurnal Teks lengkap
Predicting and Recognizing Drug‐Induced Type I Brugada Pattern Using ECG‐Based Deep Learning
BACKGROUND: Brugada syndrome (BrS) has been associated with sudden cardiac death in otherwise healthy subjects, and drug‐induced BrS accounts for 55% to 70% of all patients with BrS. This study aims to develop a deep convolutional neural network and evaluate its performance in recognizing and…
-
Artikel Jurnal Teks lengkap
Safety of the Radiofrequency Balloon for Pulmonary Vein Isolation: A Focus on Lesion Metric Analysis of Posterior Electrodes
Previous clinical studies on pulmonary vein isolation (PVI) with radiofrequency balloons (RFB) reported safe and effective procedures for a 20 s RF delivery via posterior electrodes. Recent recommendations from the manufacturer suggest reducing the application time to 15 s on the posterior wall…