Biblio Discovery — Demo Discovery Service

42 hasil untuk "Robb, Fraser"

Menampilkan 1–20 · 0,24 detik · RSS

  1. Artikel Jurnal Teks lengkap

    Optimization of steady‐state free precession MRI for lung ventilation imaging with (19)F C(3)F(8) at 1.5T and 3T

    Maunder, Adam; Rao, Madhwesha; Robb, Fraser dkk.

    Magn Reson Med · 2018 · Inggris · PubMed Central

    PURPOSE: To optimize (19)F imaging pulse sequences for perfluoropropane (C(3)F(8)) gas human lung ventilation MRI considering intrinsic in vivo relaxation parameters at both 1.5T and 3T. METHODS: Optimization of the imaging parameters for both 3D spoiled gradient (SPGR) and steady‐state free…

  2. Artikel Jurnal Teks lengkap

    Comparison of MEMS switches and PIN diodes for switched dual tuned RF coils

    Maunder, Adam; Rao, Madhwesha; Robb, Fraser dkk.

    Magn Reson Med · 2018 · Inggris · PubMed Central

    PURPOSE: To evaluate the performance of micro‐electromechanical systems (MEMS) switches against PIN diodes for switching a dual‐tuned RF coil between (19)F and (1)H resonant frequencies for multi‐nuclear lung imaging. METHODS: A four‐element fixed‐phase and amplitude transmit–receive RF coil was…

  3. Artikel Jurnal Teks lengkap

    A Semi-Blind Calibration and Compensation Method for Dynamic Range Recovery of Low-Power Pre-Amplifiers in MRI Receive Chains

    Vassos, Christopher; Robb, Fraser; Vasanawala, Shreyas dkk.

    IEEE Trans Med Imaging · 2022 · Inggris · PubMed Central

    To enable wireless MRI receive arrays, per-channel power consumption must be reduced by a significant factor. To address this, a low-power SiGe alternative to industry standard MRI pre-amplifier blocks has been proposed and its impact on imaging performance evaluated in a benchtop environment. The…

  4. Artikel Jurnal Teks lengkap

    Integrated Radio-Frequency/Wireless Coil Design for Simultaneous MR Image Acquisition and Wireless Communication

    Darnell, Dean; Cuthbertson, Jonathan; Robb, Fraser dkk.

    Magn Reson Med · 2018 · Inggris · PubMed Central

    PURPOSE: An innovative radio-frequency (RF) coil design that allows RF currents both at the Larmor frequency and in a wireless communication band to flow on the same coil is proposed to enable simultaneous MRI signal reception and wireless data transfer, thereby minimizing the number of wired…

  5. Artikel Jurnal Teks lengkap

    An RF-gated wireless power transfer system for wireless MRI receive arrays

    Byron, Kelly; Robb, Fraser; Stang, Pascal dkk.

    Concepts Magn Reson Part B Magn Reson Eng · 2018 · Inggris · PubMed Central

    In MRI systems, cable-free receive arrays would simplify setup while reducing the bulk and weight of coil arrays and improve patient comfort and throughput. Since battery power would limit scan time, wireless power transfer (WPT) is a viable option to continuously supply several watts of power to…

  6. Artikel Jurnal Teks lengkap

    Design of a volumetric cylindrical coil-tuned at 298 MHz for 7 T imaging

    Hossain, Shadeeb; Taracila, Victor; Robb, Fraser J.L. dkk.

    Instrum Sci Technol · 2023 · Inggris · PubMed Central

    The concept of a 2D cylindrical High Pass Ladder (2D c-HPL) is used in the development of this ultra high radio frequency (UHRF) volumetric head coil for 7T tuned at the Larmor frequency of 298 MHz. The architecture of the 2D c-HPL helps to overcome the challenges associated with non-uniform…

  7. Artikel Jurnal Teks lengkap

    An MRI Compatible RF MEMs Controlled Wireless Power Transfer System

    Byron, Kelly; Winkler, Simone A.; Robb, Fraser dkk.

    IEEE Trans Microw Theory Tech · 2019 · Inggris · PubMed Central

    In magnetic resonance imaging (MRI), wearable wireless receive coil arrays are a key technology goal. An MRI compatible wireless power transfer (WPT) system will be needed to realize this technology. An MRI WPT system must withstand the extreme electromagnetic environment of the scanner and cannot…

  8. Artikel Jurnal Teks lengkap

    MRSaiFE: An AI-based Approach Towards the Real-Time Prediction of Specific Absorption Rate

    GOKYAR, SAYIM; ROBB, FRASER J. L.; KAINZ, WOLFGANG dkk.

    IEEE Access · 2021 · Inggris · PubMed Central

    The purpose of this study is to investigate feasibility of estimating the specific absorption rate (SAR) in MRI in real time. To this goal, SAR maps are predicted from 3T- and 7T-simulated magnetic resonance (MR) images in 10 realistic human body models via a convolutional neural network…

  9. Artikel Jurnal Teks lengkap

    Flexible Multi-Purpose Integrated RF/Shim Coil Array for MRI and Localized B(0) Shimming

    Overson, Devon Karl; Darnell, Dean; Robb, Fraser dkk.

    Magn Reson Med · 2023 · Inggris · PubMed Central

    PURPOSE: To develop a flexible, lightweight, and multi-purpose integrated parallel reception, excitation, and shimming (iPRES) coil array that can conform to the subject’s anatomy and perform MR imaging and localized B(0) shimming in different anatomical regions with a high SNR, shimming…

  10. Artikel Jurnal Teks lengkap

    Caterpillar Traps: A Highly Flexible, Distributed System of Toroidal Cable Traps

    Karasan, Ekin; Hammerschmidt, Alison; Arias, Ana Claudia dkk.

    Magn Reson Med · 2023 · Inggris · PubMed Central

    PURPOSE: Coil arrays are connected to the main MRI system with long, shielded coaxial cables. Radiofrequency (RF) coupling of these cables to the main transmit coil can cause high shield currents, which pose risks of heating and RF burns. High-blocking resonant RF traps are placed at distinct…

  11. Artikel Jurnal Teks lengkap

    Adaptive Integrated Parallel Reception, Excitation, and Shimming (iPRES-A) with Microelectromechanical Systems Switches

    Darnell, Dean; Ma, Yixin; Wang, Hongyuan dkk.

    Magn Reson Med · 2017 · Inggris · PubMed Central

    PURPOSE: Integrated parallel reception, excitation, and shimming coil arrays with N shim loops per radio-frequency (RF) coil element (iPRES(N)) allow an RF current and N direct currents (DC) to flow in each coil element, enabling simultaneous reception/excitation and shimming of highly localized…

  12. Artikel Jurnal Teks lengkap

    Pregnant Women Models Analyzed for RF Exposure and Temperature Increase in 3T RF Shimmed Birdcages

    Murbach, Manuel; Neufeld, Esra; Samaras, Theodoros dkk.

    Magn Reson Med · 2016 · Inggris · PubMed Central

    PURPOSE: MRI is increasingly used to scan pregnant patients. We investigated the effect of 3 Tesla (T) two-port radiofrequency (RF) shimming in anatomical pregnant women models. THEORY AND METHODS: RF shimming improves B(1)(+) uniformity, but may at the same time significantly alter the induced…

  13. Artikel Jurnal Teks lengkap

    An iPRES-W Coil Array for Simultaneous Imaging and Wireless Localized B(0) Shimming of the Cervical Spinal Cord

    Cuthbertson, Jonathan D.; Truong, Trong-Kha; Stormont, Robert dkk.

    Magn Reson Med · 2022 · Inggris · PubMed Central

    PURPOSE: To develop a wireless integrated parallel reception, excitation, and shimming (iPRES-W) coil array for simultaneous imaging and wireless localized B(0) shimming and to demonstrate its ability to correct for distortions in diffusion tensor imaging (DTI) of the spinal cord in vivo. METHODS…

  14. Artikel Jurnal Teks lengkap

    Characterizing the imaging environment for supine breast MRI

    Zimmermann, Judith; Vincent, Jana; Robb, Fraser dkk.

    Magn Reson Med · 2025 · Inggris · PubMed Central

    PURPOSE: Supine breast MRI has the potential to improve over standard prone breast magnetic resonance imaging (MRI) in terms of efficiency and image quality, image alignment with diagnostic and treatment procedures, and overall accessibility. This study aims to characterize potential technical…

  15. Artikel Jurnal Teks lengkap

    Depletion-Mode GaN HEMT Q-Spoil Switches for MRI Coils

    Lu, Jonathan Y.; Grafendorfer, Thomas; Zhang, Tao dkk.

    IEEE Trans Med Imaging · 2016 · Inggris · PubMed Central

    Q-spoiling is the process of decoupling an MRI receive coil to protect the equipment and patient. Conventionally, Q-spoiling is performed using a PIN diode switch that draws significant current. In this work, a Q-spoiling technique using a depletion-mode Gallium Nitride HEMT device was developed…

  16. Artikel Jurnal Teks lengkap

    Numerical simulations of an integrated radio-frequency/wireless coil design for simultaneous acquisition and wireless transfer of magnetic resonance imaging data

    Overson, Devon K; Bresticker, Julia; Willey, Devin dkk.

    Phys Med Biol · 2023 · Inggris · PubMed Central

    Objective. A novel magnetic resonance imaging (MRI) radio-frequency (RF) coil design, termed an integrated RF/wireless (iRFW) coil design, can simultaneously perform MRI signal reception and far-field wireless data transfer with the same coil conductors between the coil in the scanner bore and an…

  17. Artikel Jurnal Teks lengkap

    Custom-Fitted 16-Channel Bilateral Breast Coil for Bidirectional Parallel Imaging

    Nnewihe, Anderson N.; Grafendorfer, Thomas; Daniel, Bruce L. dkk.

    Magn Reson Med · 2011 · Inggris · PubMed Central

    A 16-channel receive-only, closely-fitted array coil is described and tested in vivo for bilateral breast imaging at 3T. The primary purpose of this coil is to provide high SNR and parallel imaging acceleration in two directions for breast MRI. Circular coil elements (7.5 cm-diameter) were placed…

  18. Artikel Jurnal Teks lengkap

    MRI retrospective respiratory gating and cardiac sensing by CW Doppler radar: A feasibility study

    Lee, Wonje; Ryu, Kanghyun; Li, Zhitao dkk.

    IEEE Trans Biomed Eng · 2025 · Inggris · PubMed Central

    OBJECTIVE: This study investigates the feasibility of non-contact retrospective respiratory gating and cardiac sensing using continuous wave Doppler radar deployed in an MRI system. The proposed technique can complement existing sensors which are difficult to apply for certain patient populations…

  19. Artikel Jurnal Teks lengkap

    Relative SNR Measurements in Supine vs. Prone Breast MRI

    Hess, Jeremiah J.; Moran, Catherine J.; Shah, Preya dkk.

    Magn Reson Med · 2025 · Inggris · PubMed Central

    PURPOSE: Supine breast MRI has the potential to improve patient comfort compared to prone breast MRI, in addition to providing images in the same position as subsequent treatment protocols. Novel flexible coil arrays have enabled high SNR and parallel imaging in supine breast imaging, but the…

  20. Artikel Jurnal Teks lengkap

    Design and Dynamic In Vivo Validation of a Multi-Channel Stretchable Liquid Metal Coil Array

    Motovilova, Elizaveta; Ching, Terry; Vincent, Jana dkk.

    Materials (Basel) · 2024 · Inggris · PubMed Central

    Recent developments in the field of radiofrequency (RF) coils for magnetic resonance imaging (MRI) offer flexible and patient-friendly solutions. Previously, we demonstrated a proof-of-concept single-element stretchable coil design based on liquid metal and a self-tuning smart geometry. In this…