Coil combination for receive array spectroscopy: Are data‐driven methods superior to methods using computed field maps?
PURPOSE: Combining spectra from receive arrays, particularly X‐nuclear spectra with low signal‐to‐noise ratios (SNRs), is challenging. We test whether data‐driven combination methods are better than using computed coil sensitivities. THEORY: Several combination algorithms are recast into the…
-
Artikel Jurnal Teks lengkap
Hexagonal gradient scheme with RF spoiling improves spoiling performance for high‐flip‐angle fast gradient echo imaging
PURPOSE: To present a framework in which time‐varying gradients are applied with RF spoiling to reduce unwanted signal, particularly at high flip angles. METHODS: A time‐varying gradient spoiler scheme compatible with RF spoiling is defined, in which spoiler gradients cycle through the vertices of…
-
Artikel Jurnal Teks lengkap
Cardiac gating using scattering of an 8‐channel parallel transmit coil at 7T
PURPOSE: To establish a cardiac signal from scattering matrix or scattering coefficient measurements made on a 7T 8‐channel parallel transmit (pTx) system, and to evaluate its use for cardiac gating. METHODS: Measurements of the scattering matrix and scattering coefficients were acquired using a…
-
Artikel Jurnal Teks lengkap
Bloch‐Siegert [Formula: see text] ‐mapping for human cardiac (31)P‐MRS at 7 Tesla
PURPOSE: Phosphorus MR spectroscopy ((31)P‐MRS) is a powerful tool for investigating tissue energetics in vivo. Cardiac (31)P‐MRS is typically performed using surface coils that create an inhomogeneous excitation field across the myocardium. Accurate measurements of [Formula: see text] (and hence…
-
Artikel Jurnal Teks lengkap
In-vivo T2 mapping of atherosclerotic plaques in carotid arteries
Juga tersedia di: PubMed Central
-
Artikel Jurnal Teks lengkap
Gaussian modelling for operator-independent and threshold-free volumetric segmentation of phase sensitive inversion recovery late gadolinium enhanced images
Juga tersedia di: PubMed Central
-
Artikel Jurnal Teks lengkap
Rapid Quantification of Myocardial Lipid Content in Humans Using Single Breath-Hold (1)H MRS at 3 Tesla
A rapid, proton magnetic resonance spectroscopy method to evaluate human myocardial lipid levels in a single breath-hold at 3 T using a commercial whole-body system is presented. During a 10 s breath-hold, water unsuppressed and suppressed spectra were acquired by two phased array coils using a…
-
Artikel Jurnal Teks lengkap
Scattering matrix imaging pulse design for real‐time respiration and cardiac motion monitoring
PURPOSE: The scattering matrix (S‐matrix) of a parallel transmit (pTx) coil is sensitive to physiological motion but requires additional monitoring RF pulses to be measured. In this work, we present and evaluate pTx RF pulse designs that simultaneously excite for imaging and measure the S‐matrix to…
-
Artikel Jurnal Teks lengkap
Influence of fat on liver T (1) measurements using modified Look–Locker inversion recovery (MOLLI) methods at 3T
PURPOSE: To characterize the effect of fat on modified Look–Locker inversion recovery (MOLLI) T (1) maps of the liver. The balanced steady‐state free precession (bSSFP) sequence causes water and fat signals to have opposite phase when repetition time (TR) = 2.3 msec at 3T. In voxels that contain…
-
Artikel Jurnal Teks lengkap
Creatine kinase rate constant in the human heart measured with 3D‐localization at 7 tesla
PURPOSE: We present a new Bloch‐Siegert four Angle Saturation Transfer (BOAST) method for measuring the creatine kinase (CK) first‐order effective rate constant k(f) in human myocardium at 7 tesla (T). BOAST combines a variant of the four‐angle saturation transfer (FAST) method using…
-
Artikel Jurnal Teks lengkap
The effect of and correction for through‐slice dephasing on 2D gradient‐echo double angle [Formula: see text] mapping
PURPOSE: To show that [Formula: see text] variations through slice and slice profile effects are two major confounders affecting 2D dual angle [Formula: see text] maps using gradient‐echo signals and thus need to be corrected to obtain accurate [Formula: see text] maps. METHODS: The 2D…
-
Artikel Jurnal Teks lengkap
Optimal flip angles for in vivo liver 3D T (1) mapping and B (1+) mapping at 3T
PURPOSE: The spoiled gradient recalled echo (SPGR) sequence with variable flip angles (FAs) enables whole liver [Formula: see text] mapping at high spatial resolutions but is strongly affected by [Formula: see text] inhomogeneities. The aim of this work was to study how the precision of acquired…
-
Artikel Jurnal Teks lengkap
T1 Mapping of the Abdomen, From the AJR “How We Do It” Special Series