Biblio Discovery — Demo Discovery Service

28 hasil untuk "Rodbard, David"

Menampilkan 1–20 · 0,60 detik · RSS

  1. Artikel Jurnal Teks lengkap

    The Challenges of Measuring Glycemic Variability

    Rodbard, David

    J Diabetes Sci Technol · 2012 · Inggris · PubMed Central

    This commentary reviews several of the challenges encountered when attempting to quantify glycemic variability and correlate it with risk of diabetes complications. These challenges include (1) immaturity of the field, including problems of data accuracy, precision, reliability, cost, and…

  2. Artikel Jurnal Teks lengkap

    Display of Glucose Distributions by Date, Time of Day, and Day of Week: New and Improved Methods

    Rodbard, David

    J Diabetes Sci Technol · 2009 · Inggris · PubMed Central

    OBJECTIVE: There is a need for improved methods for display of glucose distributions to facilitate comparisons by date, time of day, day of the week, and other variables for data obtained using self-monitoring of blood glucose (SMBG) and continuous glucose monitoring (CGM). METHOD: Stacked bar…

  3. Artikel Jurnal Teks lengkap

    A Semilogarithmic Scale for Glucose Provides a Balanced View of Hyperglycemia and Hypoglycemia

    Rodbard, David

    J Diabetes Sci Technol · 2009 · Inggris · PubMed Central

    OBJECTIVE: It would be desirable to improve the ability of physicians and patients to identify hypoglycemic episodes when viewing displays of glucose by date, time of day, or day of the week. RESEARCH DESIGN AND METHODS: A logarithmic scale is utilized for display of glucose versus date and time of…

  4. Artikel Jurnal Teks lengkap

    New Approaches to Display of Self-Monitoring of Blood Glucose Data

    Rodbard, David

    J Diabetes Sci Technol · 2009 · Inggris · PubMed Central

    BACKGROUND: There is a need for improved methods for display and analysis of self-monitoring of blood glucose (SMBG) data to facilitate identification of clinical problems, assist the clinician in the interpretation of daily patterns and longitudinal trends, serve as a guide to locating the most…

  5. Artikel Jurnal Teks lengkap

    Optimizing Display, Analysis, Interpretation and Utility of Self-Monitoring of Blood Glucose (SMBG) Data for Management of Patients with Diabetes

    Rodbard, David

    J Diabetes Sci Technol · 2007 · Inggris · PubMed Central

    BACKGROUND: Self-monitoring of blood glucose (SMBG) data have not been used to fullest advantage. Few physicians routinely download data from memory-equipped glucose meters and perform systematic analyses and interpretation of the data. There is need for improved methods for display and analysis of…

  6. Artikel Jurnal Teks lengkap

    The Role of Information and Microcomputer Consultation Systems for Diagnostic, Therapeutic, and Educational Purposes: A Commentary

    Rodbard, David

    Proc Annu Symp Comput Appl Med Care · 1984 · Inggris · PubMed Central

    The papers presented in this session indicate the wide spectrum of medical applications of computers, including information retrieval and consultation systems for diagnosis and selection of therapy. These functioning prototypes illustrate both the pros and cons of a) use of common…

  7. Artikel Jurnal Teks lengkap

    State of Type 1 Diabetes Care in the United States in 2016–2018 from T1D Exchange Registry Data

    Rodbard, David

    Diabetes Technol Ther · 2019 · Inggris · PubMed Central

  8. Artikel Jurnal Teks lengkap

    Continuous Glucose Monitoring: A Review of Recent Studies Demonstrating Improved Glycemic Outcomes

    Rodbard, David

    Diabetes Technol Ther · 2017 · Inggris · PubMed Central

    Continuous Glucose Monitoring (CGM) has been demonstrated to be clinically valuable, reducing risks of hypoglycemia and hyperglycemia, glycemic variability (GV), and improving patient quality of life for a wide range of patient populations and clinical indications. Use of CGM can help reduce HbA1c…

  9. Artikel Jurnal Teks lengkap

    Continuous Glucose Monitoring: A Review of Successes, Challenges, and Opportunities

    Rodbard, David

    Diabetes Technol Ther · 2016 · Inggris · PubMed Central

    Continuous glucose monitoring (CGM) provides information unattainable by intermittent capillary blood glucose, including instantaneous real-time display of glucose level and rate of change of glucose, alerts and alarms for actual or impending hypo- and hyperglycemia, “24/7” coverage, and the…

  10. Artikel Jurnal Teks lengkap

    Characterizing Accuracy and Precision of Glucose Sensors and Meters

    Rodbard, David

    J Diabetes Sci Technol · 2014 · Inggris · PubMed Central

    There is need for a method to describe precision and accuracy of glucose measurement as a smooth continuous function of glucose level rather than as a step function for a few discrete ranges of glucose. We propose and illustrate a method to generate a “Glucose Precision Profile” showing absolute…

  11. Artikel Jurnal Teks lengkap

    Evaluating Quality of Glycemic Control

    Rodbard, David

    J Diabetes Sci Technol · 2014 · Inggris · PubMed Central

    BACKGROUND: There is need for readily understandable graphical displays of glucose data to facilitate interpretation by clinicians and researchers. METHODS: (1) Display of the percentage of glucose values above a specified threshold for hyperglycemia (%High) versus percentage of glucose values…

  12. Artikel Jurnal Teks lengkap

    Unified Theory for Gel Electrophoresis and Gel Filtration

    Rodbard, David; Chrambach, Andreas

    Proc Natl Acad Sci U S A · 1970 · Inggris · PubMed Central

    Unified theory for gel electrophoresis and gel filtration: The behavior of macromolecules in gel filtration and gel electrophoresis may be predicted from Ogston's model for a random meshwork of fibers. This model has been generalized to apply to nonspherical molecules and to several gel types. The…

  13. Artikel Jurnal Teks lengkap

    Design of a Decision Support System to Help Clinicians Manage Glycemia in Patients with Type 2 Diabetes Mellitus

    Rodbard, David; Vigersky, Robert A

    J Diabetes Sci Technol · 2011 · Inggris · PubMed Central

    OBJECTIVE: We sought to develop a computerized clinical decision support for clinicians treating patients with type 2 diabetes mellitus (T2DM). METHODS: We designed, developed, and tested a computer-assisted decision support (CADS) system using statistical analyses of self-monitoring of blood…

  14. Artikel Jurnal Teks lengkap

    Rapid Improvement of Glycemic Control in Type 2 Diabetes Using Weekly Intensive Multifactorial Interventions: Structured Glucose Monitoring, Patient Education, and Adjustment of Therapy—A Randomized Controlled Trial

    Pimazoni-Netto, Augusto; Rodbard, David; Zanella, Maria Teresa

    Diabetes Technol Ther · 2011 · Inggris · PubMed Central

    BACKGROUND: We evaluated intensive intervention in poorly controlled patients with type 2 diabetes mellitus involving weekly clinic visits and adjustment of therapy with analysis of three seven-point glucose profiles and intervention from an interdisciplinary staff. METHODS: Sixty-three patients…

  15. Artikel Jurnal Teks lengkap

    The Minimum Frequency of Glucose Measurements from Which Glycemic Variation Can Be Consistently Assessed

    Baghurst, Peter A; Rodbard, David; Cameron, Fergus J

    J Diabetes Sci Technol · 2010 · Inggris · PubMed Central

    AIMS: While there has been much debate about the clinical importance of glycemic variation (GV), little attention has been directed to the properties of data sets from which it is measured. The purpose of this study is to assess the minimum frequency of glucose measurements from which GV can be…

  16. Artikel Jurnal Teks lengkap

    A Data Management Program to Assist with Home Monitoring of Blood Glucose and Self Adjustment of Insulin Dosage for Patients with Diabetes Mellitus and Their Physicians

    Rodbard, David; Jaffe, Mitchell; Beveridge, Michael dkk.

    Proc Annu Symp Comput Appl Med Care · 1984 · Inggris · PubMed Central

    We have developed a microcomputer-based system for physicians and their diabetic patients that allows daily insulin, glucose, and other pertinent data to be entered, and prints graphs, statistical analyses and recommended changes in insulin dosage. Suggestions are made regarding before meal…

  17. Artikel Jurnal Teks lengkap

    Characterizing insulin dosing behaviour and glycaemic excursions: Development of metrics using connected insulin pen and continuous glucose monitoring

    Wolpert, Howard; Rodbard, David; Xue, Jie dkk.

    Diabetes Obes Metab · 2025 · Inggris · PubMed Central

    AIMS: Connected insulin pens (CIPs) provide insulin dosing data that can be leveraged to drive improvements in glycaemic control. To realize this potential in routine care, insulin data need to be distilled into actionable insights for clinicians. We describe two algorithms for detecting glucose…

  18. Artikel Jurnal Teks lengkap

    Proof-of-concept Application of Continuous Glucose Monitoring Data Analytics to Identify Diabetes Glucotypes

    Steenkamp, Devin W; Cheney, Michael C; Ju, Zhihui dkk.

    J Endocr Soc · 2023 · Inggris · PubMed Central

    BACKGROUND: In this proof-of-concept study, we evaluated if monogenic diabetes resulting from mutations of the HNF-1α gene (HNF1A-MODY) has a distinctive continuous glucose monitoring (CGM) glucotype, in comparison to type 1 diabetes (T1D). METHODS: Using CGM data from 5 subjects with HNF1A-MODY…