23 results for "Sieniewicz, Benjamin"
Showing 1–20 · 0.36 seconds · RSS
-
Journal Article Full text
Chronic Right Ventricular Pacing in the Heart Failure Population
PURPOSE OF REVIEW: We review the trials that have demonstrated potentially harmful effects from right ventricular (RV) apical pacing as well as reviewing the evidence of alternative RV pacing sites and cardiac resynchronization therapy (CRT) for patients who have heart failure and atrioventricular…
-
Journal Article Full text
Takotsubo cardiomyopathy findings on cardiac magnetic resonance imaging following immersion pulmonary oedema
Immersion pulmonary oedema (IPO) can affect sea swimmers, snorkelers, and scuba divers. It can be fatal and cases are often mistaken for drowning. There has been an association between IPO and the development of takotsubo cardiomyopathy. We present a case study of a diver rescued from the water…
-
Journal Article Full text
Successful percutaneous femoral extraction of a detached tricuspid valve‐in‐valve balloon delivery system
We shall discuss a patient who underwent a tricuspid valve‐in‐valve implantation for a failing bioprosthetic valve replacement. The procedure was complicated by detachment of the valve deployment apparatus which was removed in its entirety, using percutaneous extraction techniques. We believe this…
-
Journal Article Full text
Economic evaluation of a dedicated cardiac resynchronisation therapy preassessment clinic
INTRODUCTION: Patient evaluation before cardiac resynchronisation therapy (CRT) remains heterogeneous across centres and it is suspected a proportion of patients with unfavourable characteristics proceed to implantation. We developed a unique CRT preassessment clinic (CRT PAC) to act as a final…
-
Journal Article Full text
Comparative Analysis of Response to Cardiac Resynchronisation Therapy Upgrades in Patients with Implantable Cardioverter-Defibrillators and Pacemakers
Introduction: The efficacy of de novo cardiac resynchronisation therapy (CRT) in patients with heart failure (HF), left ventricular systolic dysfunction (LVSD), and a broad QRS morphology is well established. However, the optimal stage for upgrading patients with existing pacemakers (PPMs) or…
-
Journal Article Full text
Understanding non-response to cardiac resynchronisation therapy: common problems and potential solutions
Heart failure is a complex clinical syndrome associated with a significant morbidity and mortality burden. Reductions in left ventricular (LV) function trigger adaptive mechanisms, leading to structural changes within the LV and the potential development of dyssynchronous ventricular activation…
-
Journal Article Full text
Optimal site selection and image fusion guidance technology to facilitate cardiac resynchronization therapy
Introduction: Cardiac resynchronization therapy (CRT) has emerged as one of the few effective treatments for heart failure. However, up to 50% of patients derive no benefit. Suboptimal left ventricle (LV) lead position is a potential cause of poor outcomes while targeted lead deployment has been…
-
Journal Article Full text
Optimization of CRT programming using non‐invasive electrocardiographic imaging to assess the acute electrical effects of multipoint pacing
AIM: Quadripolar lead technology and multi‐point pacing (MPP) are important clinical adjuncts in cardiac resynchronization therapy (CRT) pacing aimed at reducing the rate of non‐response to therapy. Mixed results have been achieved using MPP and it is critical to identify which patients require…
-
Journal Article Full text
LV function validation of computer-assisted interventional system for cardiac resyncronisation therapy
PURPOSE: Cardiac resynchronisation therapy (CRT) is an established treatment for symptomatic patients with heart failure, a prolonged QRS duration, and impaired left ventricular (LV) function; however, non-response rates remain high. Recently proposed computer-assisted interventional platforms for…
-
Journal Article Full text
The Emerging Role of Cardiac Magnetic Resonance Imaging in the Evaluation of Patients with HFpEF
PURPOSE OF REVIEW: To give an update on the emerging role of cardiac magnetic resonance imaging in the evaluation of patients with heart failure with preserved ejection fraction (HFpEF). This is important as the diagnosis of HFpEF remains challenging and cardiac imaging is pivotal in establishing…
-
Journal Article Full text
Financial and resource costs of transvenous lead extraction in a high-volume lead extraction centre
OBJECTIVES: Transvenous lead extraction (TLE) poses a significant economic and resource burden on healthcare systems; however, limited data exist on its true cost. We therefore estimate real-world healthcare reimbursement costs of TLE to the UK healthcare system at a single extraction centre…
-
Journal Article Full text
Sex-Dependent QRS Guidelines for Cardiac Resynchronization Therapy Using Computer Model Predictions
Cardiac resynchronization therapy (CRT) is an important treatment for heart failure. Low female enrollment in clinical trials means that current CRT guidelines may be biased toward males. However, females have higher response rates at lower QRS duration (QRSd) thresholds. Sex differences in the…
-
Journal Article Full text
Comparison of Echocardiographic and Electrocardiographic Mapping for Cardiac Resynchronisation Therapy Optimisation
STUDY HYPOTHESIS: We sought to investigate the association between echocardiographic optimisation and ventricular activation time in cardiac resynchronisation therapy (CRT) patients, obtained through the use of electrocardiographic mapping (ECM). We hypothesised that echocardiographic optimisation…
-
Journal Article Full text
Autonomic Modulation in Patients with Heart Failure Increases Beat-to-Beat Variability of Ventricular Action Potential Duration
Background: Exaggerated beat-to-beat variability of ventricular action potential duration (APD) is linked to arrhythmogenesis. Sympathetic stimulation has been shown to increase QT interval variability, but its effect on ventricular APD in humans has not been determined. Methods and Results: Eleven…
-
Journal Article Full text
Pacing in proximity to scar during cardiac resynchronization therapy increases local dispersion of repolarization and susceptibility to ventricular arrhythmogenesis
BACKGROUND: Cardiac resynchronization therapy (CRT) increases the risk of ventricular tachycardia (VT) in patients with ischemic cardiomyopathy (ICM) when the left ventricular (LV) epicardial lead is implanted in proximity to scar. OBJECTIVE: The purpose of this study was to determine the…
-
Journal Article Full text
Beat-to-Beat Variability of Ventricular Action Potential Duration Oscillates at Low Frequency During Sympathetic Provocation in Humans
Background: The temporal pattern of ventricular repolarization is of critical importance in arrhythmogenesis. Enhanced beat-to-beat variability (BBV) of ventricular action potential duration (APD) is pro-arrhythmic and is increased during sympathetic provocation. Since sympathetic nerve activity…
-
Journal Article Full text
Guided implantation of a leadless left ventricular endocardial electrode and acoustic transmitter using computed tomography anatomy, dynamic perfusion and mechanics, and predicted activation pattern
BACKGROUND: The WiSE-CRT System (EBR systems, Sunnyvale, CA) permits leadless left ventricular pacing. Currently, no intraprocedural guidance is used to target optimal electrode placement while simultaneously guiding acoustic transmitter placement in close proximity to the electrode to ensure…
-
Journal Article Full text
Feasibility of intraprocedural integration of cardiac CT to guide left ventricular lead implantation for CRT upgrades
BACKGROUND: Optimal positioning of the left ventricular (LV) lead is an important determinant of cardiac resynchronization therapy (CRT) response. OBJECTIVE: Evaluate the feasibility of intraprocedural integration of cardiac computed tomography (CT) to guide LV lead implantation for CRT upgrades…
-
Journal Article Full text
Electrical latency predicts the optimal left ventricular endocardial pacing site: results from a multicentre international registry
AIMS: The optimal site for biventricular endocardial (BIV(ENDO)) pacing remains undefined. Acute haemodynamic response (AHR) is reproducible marker of left ventricular (LV) contractility, best expressed as the change in the maximum rate of LV pressure (LV-dp/dt(max)), from a baseline state. We…