71 results for "Torricelli, Alessandro"
Showing 1–20 · 0.26 seconds · RSS
-
Journal Article Full text
Using a simulation approach to optimize time-domain diffuse correlation spectroscopy measurement on human head
Time-domain diffuse correlation spectroscopy (TD-DCS) has been recently proposed to improve detection of deep blood flow dynamics in a biological tissue, such as human brain. To obtain a high sensitive measurement, several experimental parameters such as the source–detector (SD) distance, gate…
-
Journal Article Full text
Method for the discrimination of superficial and deep absorption variations by time domain fNIRS
A method for the discrimination of superficial and deep absorption variations by time domain functional near infrared spectroscopy is presented. The method exploits the estimate of the photon time-dependent pathlength in different domains of the sampled medium and makes use of an approach based on…
-
Journal Article Full text
Effect of a thin superficial layer on the estimate of hemodynamic changes in a two-layer medium by time domain NIRS
In order to study hemodynamic changes involved in muscular metabolism by means of time domain fNIRS, we need to discriminate in the measured signal contributions coming from different depths. Muscles are, in fact, typically located under other tissues, e.g. skin and fat. In this paper, we study the…
-
Journal Article Full text
Time Domain Near Infrared Spectroscopy Device for Monitoring Muscle Oxidative Metabolism: Custom Probe and In Vivo Applications
Measurement of muscle oxidative metabolism is of interest for monitoring the training status in athletes and the rehabilitation process in patients. Time domain near infrared spectroscopy (TD NIRS) is an optical technique that allows the non-invasive measurement of the hemodynamic parameters in…
-
Journal Article Full text
Depth-selective data analysis for time-domain fNIRS: moments vs. time windows
Time-domain measurements facilitate the elimination of the influence of extracerebral, systemic effects, a key problem in functional near-infrared spectroscopy (fNIRS) of the adult human brain. The analysis of measured time-of-flight distributions of photons often relies on moments or time windows…
-
Journal Article Full text
Bone tissue phantoms for optical flowmeters at large interoptode spacing generated by 3D-stereolithography
A bone tissue phantom prototype allowing to test, in general, optical flowmeters at large interoptode spacings, such as laser-Doppler flowmetry or diffuse correlation spectroscopy, has been developed by 3D-stereolithography technique. It has been demonstrated that complex tissue vascular systems of…
-
Journal Article Full text
Noninvasive optical estimation of CSF thickness for brain-atrophy monitoring
Dementia disorders are increasingly becoming sources of a broad range of problems, strongly interfering with the normal daily tasks of a growing number of individuals. Such neurodegenerative diseases are often accompanied with progressive brain atrophy that, at late stages, leads to drastically…
-
Journal Article Full text
There’s plenty of light at the bottom: statistics of photon penetration depth in random media
We propose a comprehensive statistical approach describing the penetration depth of light in random media. The presented theory exploits the concept of probability density function f(z|ρ, t) for the maximum depth reached by the photons that are eventually re-emitted from the surface of the medium…
-
Journal Article Full text
Instrument response function acquisition in reflectance geometry for time-resolved diffuse optical measurements
In time-domain diffuse optical spectroscopy, the simultaneous acquisition of the time-of-flight distribution (DTOF) of photons traveling in a diffusive medium and of the instrument response function (IRF) is necessary to perform quantitative measurements of optical properties (absorption and…
-
Journal Article Full text
Fast Multi-Distance Time-Domain NIRS and DCS System for Clinical Applications
We have designed and built an improved system for combined Time-Domain Near-Infrared Spectroscopy (TD NIRS) and Diffuse Correlation Spectroscopy (DCS) measurements. The system features two independent channels, enabling TD NIRS and DCS acquisition at short and long source-detector distances to…
-
Journal Article Full text
Detectability of hemodynamic oscillations in cerebral cortex through functional near-infrared spectroscopy: a simulation study
SIGNIFICANCE: We explore the feasibility of using time-domain (TD) and continuous-wave (CW) functional near-infrared spectroscopy (fNIRS) to monitor brain hemodynamic oscillations during resting-state activity in humans, a phenomenon that is of increasing interest in the scientific and medical…
-
Journal Article Full text
Evaluation of layered tissue scattering properties: a time-domain spatially resolved spectroscopy approach
SIGNIFICANCE: The spatially resolved spectroscopy (SRS) approach is widely used in continuous wave near-infrared spectroscopy to estimate tissue oxygen saturation in the skeletal muscle and cerebral cortex. The extension of the SRS approach to the time domain (TD) has never been proposed. We…
-
Journal Article Full text
Probe-hosted silicon photomultipliers for time-domain functional near-infrared spectroscopy: phantom and in vivo tests
We report the development of a compact probe for time-domain (TD) functional near-infrared spectroscopy (fNIRS) based on a fast silicon photomultiplier (SiPM) that can be put directly in contact with the sample without the need of optical fibers for light collection. We directly integrated an…
-
Journal Article Full text
Cerebral time domain-NIRS: reproducibility analysis, optical properties, hemoglobin species and tissue oxygen saturation in a cohort of adult subjects
The reproducibility of cerebral time-domain near-infrared spectroscopy (TD-NIRS) has not been investigated so far. Besides, reference intervals of cerebral optical properties, of absolute concentrations of deoxygenated-hemoglobin (HbR), oxygenated-hemoglobin (HbO), total hemoglobin (HbT) and tissue…
-
Journal Article Full text
Effect of adipose tissue thickness and tissue optical properties on the differential pathlength factor estimation for NIRS studies on human skeletal muscle
We propose a quantitative and systematic investigation of the differential pathlength factor (DPF) behavior for skeletal muscles and its dependence on different factors, such as the subcutaneous adipose tissue thickness (ATT), the variations of the tissue absorption (µ(a)) and reduced scattering…
-
Journal Article Full text
A Compact Multi-Distance DCS and Time Domain NIRS Hybrid System for Hemodynamic and Metabolic Measurements
In this work, we present a new multi-distance diffuse correlation spectroscopy (DCS) device integrated with a compact state-of-the-art time domain near infrared spectroscopy (TD-NIRS) device. The hybrid DCS and TD-NIRS system allows to retrieve information on blood flow, tissue oxygenation, and…
-
Journal Article Full text
Robustness of tissue oxygenation estimates by continuous wave space-resolved near infrared spectroscopy
SIGNIFICANCE: Continuous wave near infrared spectroscopy (CW-NIRS) is widely exploited in clinics to estimate skeletal muscles and brain cortex oxygenation. Spatially resolved spectroscopy (SRS) is generally implemented in commercial devices. However, SRS suffers from two main limitations: the a…
-
Journal Article Full text
Accuracy of homogeneous models for photon diffusion in estimating neonatal cerebral hemodynamics by TD-NIRS
We assessed the accuracy of homogenous (semi-infinite, spherical) photon diffusion models in estimating absolute hemodynamic parameters of the neonatal brain in realistic scenarios (ischemia, hyperoxygenation, and hypoventilation) from 1.5 cm interfiber distance TD NIRS measurements…
-
Journal Article Full text
Multi-channel medical device for time domain functional near infrared spectroscopy based on wavelength space multiplexing
We have designed a compact dual wavelength (687 nm, 826 nm) multi-channel (16 sources, 8 detectors) medical device for muscle and brain imaging based on time domain functional near infrared spectroscopy. The system employs the wavelength space multiplexing approach to reduce wavelength cross-talk…
-
Journal Article Full text
Time-domain near-infrared spectroscopy in acute ischemic stroke patients
Large vessel occlusion (LVO) stroke might cause different degrees of hemodynamic impairment that affects microcirculation and contributes to metabolic derangement. Time-domain near-infrared spectroscopy (TD-NIRS) estimates the oxygenation of microcirculation of cerebral outer layers. We measure…