19 results for "Trapp Jamie"
Showing 1–19 · 0.38 seconds · RSS
-
Journal Article Full text
A review of image processing and analysis of computed tomography images using deep learning methods
The use of machine learning has seen extraordinary growth since the development of deep learning techniques, notably the deep artificial neural network. Deep learning methodology excels in addressing complicated problems such as image classification, object detection, and natural language…
-
Journal Article Full text
Technical note: A modified gamma evaluation method for dose distribution comparisons
PURPOSE: In this work we have developed a novel method of dose distribution comparison, the inverse gamma (IG) evaluation, by modifying the commonly used gamma evaluation method. METHODS: The IG evaluation calculates the gamma criteria (dose difference criterion, ΔD, or distance‐to‐agreement…
-
Journal Article Full text
Distributive quality assurance and delivery of stereotactic ablative radiotherapy treatments amongst beam matched linear accelerators: A feasibility study
PURPOSE: Beam matching occurs on all linacs to some degree and when two are more are matched to each other, patients are able to be transferred between machines. Quality assurance of plans can also be performed “distributively” on any of the matched linacs. The degree to which machines are matched…
-
Journal Article Full text
A simple method to account for skin dose enhancement during treatment planning of VMAT treatments of patients in contact with immobilization equipment
PURPOSE: The ability to accurately predict skin doses and thereby design radiotherapy treatments that balance the likelihood of skin reactions against other treatment objectives is especially important when hypofractionated prescription regimes are used. However, calculations of skin dose provided…
-
Journal Article Full text
Improving accuracy for stereotactic body radiotherapy treatments of spinal metastases
PURPOSE: Use of SBRT techniques is now a relatively common recourse for spinal metastases due to good local control rates and durable pain control. However, the technique has not yet reached maturity for gantry‐based systems, so work is still required in finding planning approaches that produce…
-
Journal Article Full text
A feasibility study of multislice X‐ray CT imaging of gel dosimeters using the “zero scan” method
This study extends the ‘zero scan’ method for CT imaging of polymer gel dosimeters to include multislice acquisitions. Multislice CT images consisting of 24 slices of 1.2 mm thickness were acquired of an irradiated polymer gel dosimeter and processed with the zero scan technique. The results…
-
Journal Article Full text
Statistical process control and verifying positional accuracy of a cobra motion couch using step‐wedge quality assurance tool
This study utilizes process control techniques to identify action limits for TomoTherapy couch positioning quality assurance tests. A test was introduced to monitor accuracy of the applied couch offset detection in the TomoTherapy Hi‐Art treatment system using the TQA “Step‐Wedge Helical” module…
-
Journal Article Full text
Impact of dose reducing software on patient and staff temple dose during fluoroscopically guided pacemaker insertion, closure devices implantation and coronary angiography procedures
The aim of this study is to investigate the effectiveness of dose reducing software (ClarityIQ) on patient and staff dose during fluoroscopically guided cardiac procedures. Dose measurements were collected in a room without dose reducing software (n = 157) and compared with similar procedures…
-
Journal Article Full text
A comparison of patient dose and occupational eye dose to the operator and nursing staff during transcatheter cardiac and endovascular procedures
The number and complexity of transcatheter procedures continue to increase, raising concerns regarding radiation exposure to patients and staff. Procedures such as transaortic valve implantations (TAVI) have led to cardiologists adopting higher dose techniques, such as digital subtraction…
-
Journal Article Full text
Fluoroscopically guided vascular and cardiac transcatheter procedures: a comparison of occupational and patient dose by anatomical region
X-ray guided procedures are being performed by an increasing variety of medical specialties. Due to improvements in vascular transcatheter therapies, there is an increasing overlap of imaged anatomy between medical specialties. There is concern that non-radiology fluoroscopic operators may not have…
-
Journal Article Full text
A structure-based gamma evaluation method for identifying clinically relevant dose differences in organs at risk
Gamma evaluation is currently the most widely used dose comparison method for patient specific quality assurance (PSQA). However, existing methods for normalising the dose difference, using either the dose at the global maximum dose point or at each local point, can respectively lead to under- and…
-
Journal Article Full text
The suitability of smartphone camera sensors for detecting radiation
The advanced image sensors installed on now-ubiquitous smartphones can be used to detect ionising radiation in addition to visible light. Radiation incidents on a smartphone camera’s Complementary Metal Oxide Semiconductor (CMOS) sensor creates a signal which can be isolated from a visible light…
-
Journal Article
A portable organic plastic scintillator dosimetry system for low energy X-rays: A feasibility study using an intraoperative X-ray unit as the radiation source
The effective use of near water equivalent organic plastic scintillators (OPS) for radiation dosimetry with high-energy sources under laboratory conditions is recognized. In this work, an OPS-based dosimeter using a photodiode combined with improved solid state detection and signal processing…
-
Journal Article Full text
A portable organic plastic scintillator dosimetry system for low energy X-rays: A feasibility study using an intraoperative X-ray unit as the radiation source
The effective use of near water equivalent organic plastic scintillators (OPS) for radiation dosimetry with high-energy sources under laboratory conditions is recognized. In this work, an OPS-based dosimeter using a photodiode combined with improved solid state detection and signal processing…
-
Journal Article Full text
Occupational and Patient Radiation Dose and Quality Implications of Femoral Access Imaging During Coronary Angiography
PURPOSE: Cardiologists often perform angiography of the common femoral artery (CFA) access site to evaluate whether the anatomy is suitable for deployment of a vascular closure device or to assess whether iatrogenic vessel damage has occurred. The choice of acquisition mode has radiation dose…
-
Journal Article Full text
A multi‐institutional evaluation of machine performance check system on treatment beam output and symmetry using statistical process control
BACKGROUND: The automated and integrated machine performance check (MPC) tool was verified against independent detectors to evaluate its beam uniformity and output detection abilities to consider it suitable for daily quality assurance (QA). METHODS: Measurements were carried out on six linear…
-
Journal Article Full text
Taller staff occupationally exposed to less radiation to the temple in cardiac procedures, but risk higher doses during vascular cases
This study aimed to evaluate the effect of nurse and doctor height on occupational dose to the temple during fluoroscopically guided cardiovascular procedures. Additionally, an evaluation of the relationship between doctor height and table height was performed. Staff exposed during fluoroscopic…
-
Journal Article Full text
Retrospective evaluation of dosimetric quality for prostate carcinomas treated with 3D conformal, intensity modulated and volumetric modulated arc radiotherapy
INTRODUCTION: This study examines and compares the dosimetric quality of radiotherapy treatment plans for prostate carcinoma across a cohort of 163 patients treated across five centres: 83 treated with three-dimensional conformal radiotherapy (3DCRT), 33 treated with intensity modulated…