Biblio Discovery — Demo Discovery Service

295 hasil untuk "Webb, Andrew"

Menampilkan 1–20 · 0,21 detik · RSS

  1. Artikel Jurnal Teks lengkap

    Pocket Prescriber 2009–10

    Webb, Andrew

    Br J Clin Pharmacol · 2010 · Inggris · PubMed Central

  2. Artikel Jurnal Teks lengkap

    The appropriate role of colloids in managing fluid imbalance: a critical review of recent meta-analytic findings

    Webb, Andrew R

    Crit Care · 2000 · Inggris · PubMed Central

    Three meta-analyses have recently been reported on the relationship between choice of resuscitation fluid and risk of mortality in critically ill patients. The relative risk of death (1.16-1.19) in two of the meta-analyses was slightly higher in colloid than crystalloid recipients; however, this…

  3. Artikel Jurnal Teks lengkap

    Spotlight—Introducing a new Commentary series for the BJCP

    Webb, Andrew J.

    Br J Clin Pharmacol · 2019 · Inggris · PubMed Central

  4. Artikel Jurnal Teks lengkap

    Crystalloid or colloid for resuscitation. Are we any the wiser?

    Webb, Andrew R

    Crit Care · 1999 · Inggris · PubMed Central

  5. Artikel Jurnal Teks lengkap

    Detectability of Absorption and Reduced Scattering Coefficients in Frequency-Domain Measurements Using a Realistic Head Phantom

    Zhang, Xiaofeng; Webb, Andrew

    Sensors (Basel) · 2012 · Inggris · PubMed Central

    Detection limits of the changes in absorption and reduced scattering coefficients were investigated using a frequency-domain near-infrared system in a realistic head phantom. The results were quantified in terms of the maximum detectable depth for different activation volumes in the range of 0.8–20…

  6. Artikel Jurnal Teks lengkap

    Metamaterial Combining Electric- and Magnetic-Dipole-Based Configurations for Unique Dual-Band Signal Enhancement in Ultrahigh-Field Magnetic Resonance Imaging

    Schmidt, Rita; Webb, Andrew

    ACS Appl Mater Interfaces · 2017 · Inggris · PubMed Central

    [Image: see text] Magnetic resonance imaging and spectroscopy (MRI and MRS) are both widely used techniques in medical diagnostics and research. One of the major thrusts in recent years has been the introduction of ultrahigh-field magnets in order to boost the sensitivity. Several MRI studies have…

  7. Artikel Jurnal Teks lengkap

    The permanent magnet hypothesis: an intuitive approach to designing non-circular magnet arrays with high field homogeneity

    Tewari, Sumit; Webb, Andrew

    Sci Rep · 2023 · Inggris · PubMed Central

    Does the Halbach magnetization rotation rule that is used for designing circular magnet arrays for achieving the best homogeneity hold also for an elliptical or other non-circular cross-section? In this article, it is shown that a new numerically optimized magnetization rotation rule can provide…

  8. Artikel Jurnal Teks lengkap

    Tackling SNR at low-field: a review of hardware approaches for point-of-care systems

    Webb, Andrew; O’Reilly, Thomas

    MAGMA · 2023 · Inggris · PubMed Central

    OBJECTIVE: To review the major hardware components of low-field point-of-care MRI systems which affect the overall sensitivity. METHODS: Designs for the following components are reviewed and analyzed: magnet, RF coils, transmit/receive switches, preamplifiers, data acquisition system, and methods…

  9. Artikel Jurnal Teks lengkap

    Specific absorption rate (SAR) simulations for low-field (

    Parsa, Javad; Webb, Andrew

    MAGMA · 2023 · Inggris · PubMed Central

    OBJECTIVE: To simulate the magnetic and electric fields produced by RF coil geometries commonly used at low field. Based on these simulations, the specific absorption rate (SAR) efficiency can be derived to ensure safe operation even when using short RF pulses and high duty cycles. METHODS…

  10. Artikel Jurnal Teks lengkap

    Signal-to-noise trade-offs between magnet diameter and shield-to-coil distance for cylindrical Halbach-based portable MRI systems for neuroimaging

    Parsa, Javad; Webb, Andrew

    MAGMA · 2024 · Inggris · PubMed Central

    OBJECTIVE: To investigate the trade-off between magnet bore diameter and the distance between the conductive Faraday shield and RF head coil for low-field point-of-care neuroimaging systems. METHODS: Electromagnetic simulations were performed for three different Faraday shield geometries and two…

  11. Artikel Jurnal Teks lengkap

    Vascular effects of dietary nitrate (as found in green leafy vegetables and beetroot) via the nitrate‐nitrite‐nitric oxide pathway

    Lidder, Satnam; Webb, Andrew J.

    Br J Clin Pharmacol · 2013 · Inggris · PubMed Central

    The discovery that dietary (inorganic) nitrate has important vascular effects came from the relatively recent realization of the ‘nitrate‐nitrite‐nitric oxide (NO) pathway’. Dietary nitrate has been demonstrated to have a range of beneficial vascular effects, including reducing blood pressure…

  12. Artikel Jurnal Teks lengkap

    Magnetic Resonance Microimaging and Numerical Simulations of Velocity Fields Inside Enlarged Flow Cells Used for Coupled NMR Microseparations

    Zhang, Xiaofeng; Webb, Andrew G.

    Anal Chem · 2005 · Inggris · PubMed Central

    The coupling of various chemical microseparation methods with small-scale NMR detection is a growing area in analytical chemistry. The formation of enlarged flow cells within the active volume of the NMR detector can significantly increase the coil filling factor and hence the signal-to-noise ratio…

  13. Artikel Jurnal Teks lengkap

    Spotlight Commentary: What's new with the old drug aspirin in older adults?

    Webb, Andrew James; Minuz, Pietro

    Br J Clin Pharmacol · 2019 · Inggris · PubMed Central

  14. Artikel Jurnal Teks lengkap

    CME Clinical pharmacology (100626): self-assessment questionnaire

    Webb, Andrew; Chowdhury, Tahseen A

    Clin Med (Lond) · 2016 · Inggris · PubMed Central

  15. Artikel Jurnal Teks lengkap

    In vivo T(1) and T(2) relaxation time maps of brain tissue, skeletal muscle, and lipid measured in healthy volunteers at 50 mT

    O’Reilly, Thomas; Webb, Andrew G.

    Magn Reson Med · 2021 · Inggris · PubMed Central

    PURPOSE: Low‐field (B(0) < 0.1 T) MRI has generated much interest as a means of increased accessibility via reduced cost and improved portability compared to conventional clinical systems (B(0) ≥ 1.5 Tesla). Here we measure MR relaxation times at 50 mT and compare results with commonly used models…

  16. Artikel Jurnal Teks lengkap

    Axonal and glial microstructural information obtained with diffusion-weighted magnetic resonance spectroscopy at 7T

    Ronen, Itamar; Ercan, Ece; Webb, Andrew

    Front Integr Neurosci · 2013 · Inggris · PubMed Central

    Diffusion-weighted magnetic resonance spectroscopy (DWS) offers unique access to compartment-specific microstructural information on tissue, and potentially sensitive detection of compartment-specific changes in disease. The specificity of DWS is, however, offset by its relative low sensitivity…

  17. Artikel Jurnal Teks lengkap

    The need for a prescribing competency framework to address the burden of complex polypharmacy among multiple long-term conditions

    Picton, Catherine; Loughrey, Claire; Webb, Andrew

    Clin Med (Lond) · 2016 · Inggris · PubMed Central

    The original requirement for a competency framework for prescribers was to identify the essential skills for non-medical prescribers. However, core prescribing competencies are relevant to any prescriber. The new, revised version is especially relevant for doctors/physicians. Doctors are the most…

  18. Artikel Jurnal Teks lengkap

    Shielded‐coaxial‐cable coils as receive and transceive array elements for 7T human MRI

    Ruytenberg, Thomas; Webb, Andrew; Zivkovic, Irena

    Magn Reson Med · 2019 · Inggris · PubMed Central

    PURPOSE: To investigate the use of shielded‐coaxial‐cable (SCC) coils as elements for multi‐channel receive‐only and transceive arrays for 7T human MRI and to compare their performance with equivalently sized conventional loop coils. METHODS: The SCC coil element consists of a coaxial loop with…

  19. Artikel Jurnal Teks lengkap

    A de novo MS1 feature detector for the Bruker timsTOF Pro

    Wilding-McBride, Daryl; Webb, Andrew I.

    PLoS One · 2022 · Inggris · PubMed Central

    Identification of peptides by analysis of data acquired by the two established methods for bottom-up proteomics, DDA and DIA, relies heavily on the fragment spectra. In DDA, peptide features detected in mass spectrometry data are identified by matching their fragment spectra with a peptide…