14 hasil untuk "Wojtkiewicz, Stanislaw"
Menampilkan 1–14 · 0,34 detik · RSS
-
Artikel Jurnal Teks lengkap
Time-resolved near infrared light propagation using frequency domain superposition
Time-resolved temporal point spread function (TPSF) measurement of near infrared spectroscopic (NIRS) data allows the estimation of absorption and reduced scattering properties of biological tissues. Such analysis requires an iterative calculation of the theoretical TPSF curve using mathematical…
-
Artikel Jurnal Teks lengkap
Lock-in functional near-infrared spectroscopy for measurement of the haemodynamic brain response
Here we show a method of the lock-in amplifying near-infrared signals originating within a human brain. It implies using two 90-degree rotated source-detector pairs fixed on a head surface. Both pairs have a joint sensitivity region located towards the brain. A direct application of the lock-in…
-
Artikel Jurnal Teks lengkap
Oxygen-dependent functional brain haemodynamic response
The influence of hypoxia - a condition where tissues are under oxygen deficiency - on the human brain under functional load has not been fully understood yet. This study aims to analyse the effects of hypoxia on the brain’s haemodynamic response under visual stimulation, using the in-house…
-
Artikel Jurnal Teks lengkap
Performance of measurands in time-domain optical brain imaging: depth selectivity versus contrast-to-noise ratio
Time-domain optical brain imaging techniques introduce a number of different measurands for analyzing absorption changes located deep in the tissue, complicated by superficial absorption changes and noise. We implement a method that allows analysis, quantitative comparison and performance ranking…
-
Artikel Jurnal Teks lengkap
Approaches for modelling autocorrelation function and data processing in time-domain diffuse correlation spectroscopy
Time-domain diffuse correlation spectroscopy (TD-DCS) is a non-invasive optical technique for measuring tissue blood flow. Recovering the blood flow index (αD(b)) requires accurate modelling of the normalised electric field autocorrelation function (g(1)), and an optimised data processing approach…
-
Artikel Jurnal Teks lengkap
Toward real-time diffuse optical tomography: accelerating light propagation modeling employing parallel computing on GPU and CPU
Parameter recovery in diffuse optical tomography is a computationally expensive algorithm, especially when used for large and complex volumes, as in the case of human brain functional imaging. The modeling of light propagation, also known as the forward problem, is the computational bottleneck of…
-
Artikel Jurnal Teks lengkap
Depth-resolved assessment of changes in concentration of chromophores using time-resolved near-infrared spectroscopy: estimation of cytochrome-c-oxidase uncertainty by Monte Carlo simulations
Time-resolved near-infrared spectroscopy (TR-NIRS) measurements can be used to recover changes in concentrations of tissue constituents ([Formula: see text]) by applying the moments method and the Beer-Lambert law. In this work we carried out the error propagation analysis allowing to calculate the…
-
Artikel Jurnal Teks lengkap
Self-calibrating time-resolved near infrared spectroscopy
Time-resolved near infrared spectroscopy is considered to be a gold standard technique when measuring absolute values of tissue optical properties, as it provides separable and independent information about both tissue absorption and scattering. However, time-resolved instruments require an…
-
Artikel Jurnal Teks lengkap
Assessment of the brain ischemia during orthostatic stress and lower body negative pressure in air force pilots by near-infrared spectroscopy
A methodology for the assessment of the cerebral hemodynamic reaction to normotensive hypovolemia, reduction in cerebral perfusion and orthostatic stress leading to ischemic hypoxia and reduced muscular tension is presented. Most frequently, the pilots of highly maneuverable aircraft are exposed to…
-
Artikel Jurnal Teks lengkap
Performance assessment of laser sources for time-domain diffuse correlation spectroscopy
Time-domain diffuse correlation spectroscopy (TD-DCS) is an emerging optical technique that enables noninvasive measurement of microvascular blood flow with photon path-length resolution. In TD-DCS, a picosecond pulsed laser with a long coherence length, adequate illumination power, and narrow…
-
Artikel Jurnal Teks lengkap
Time-domain NIRS system based on supercontinuum light source and multi-wavelength detection: validation for tissue oxygenation studies
We present and validate a multi-wavelength time-domain near-infrared spectroscopy (TD-NIRS) system that avoids switching wavelengths and instead exploits the full capability of a supercontinuum light source by emitting and acquiring signals for the whole chosen range of wavelengths. The system was…
-
Artikel Jurnal Teks lengkap
Recipes for diffuse correlation spectroscopy instrument design using commonly utilized hardware based on targets for signal-to-noise ratio and precision
Over the recent years, a typical implementation of diffuse correlation spectroscopy (DCS) instrumentation has been adapted widely. However, there are no detailed and accepted recipes for designing such instrumentation to meet pre-defined signal-to-noise ratio (SNR) and precision targets. These…
-
Artikel Jurnal Teks lengkap
The LUCA device: a multi-modal platform combining diffuse optics and ultrasound imaging for thyroid cancer screening
We present the LUCA device, a multi-modal platform combining eight-wavelength near infrared time resolved spectroscopy, sixteen-channel diffuse correlation spectroscopy and a clinical ultrasound in a single device. By simultaneously measuring the tissue hemodynamics and performing ultrasound…
-
Artikel Jurnal Teks lengkap
Near-infrared diffuse optical characterization of human thyroid using ultrasound-guided hybrid time-domain and diffuse correlation spectroscopies
Thyroid vascularization and hemodynamics become altered in thyroid pathologies and could thus inform diagnostics, therapy planning, and follow-up. However, the current non-invasive monitoring methods available in clinics lack the necessary sensitivity and/or are impractical for large-scale…