Biblio Discovery — Demo Discovery Service

20 hasil untuk "Yang, Ching-Ching"

Menampilkan 1–20 · 1,38 detik · RSS

  1. Artikel Jurnal Teks lengkap

    Characterization of Scattered X-Ray Photons in Dental Cone-Beam Computed Tomography

    Yang, Ching-Ching

    PLoS One · 2016 · Inggris · PubMed Central

    PURPOSE: Scatter is a very important artifact causing factor in dental cone-beam CT (CBCT), which has a major influence on the detectability of details within images. This work aimed to improve the image quality of dental CBCT through scatter correction. METHODS: Scatter was estimated in the…

  2. Artikel Jurnal Teks lengkap

    Compensating Positron Range Effects of Ga-68 in Preclinical PET Imaging by Using Convolutional Neural Network: A Monte Carlo Simulation Study

    Yang, Ching-Ching

    Diagnostics (Basel) · 2021 · Inggris · PubMed Central

    This study aimed to investigate the feasibility of positron range correction based on three different convolutional neural network (CNN) models in preclinical PET imaging of Ga-68. The first model (CNN1) was originally designed for super-resolution recovery, while the second model (CNN2) and the…

  3. Artikel Jurnal Teks lengkap

    Evaluation of Impact of Factors Affecting CT Radiation Dose for Optimizing Patient Dose Levels

    Yang, Ching-Ching

    Diagnostics (Basel) · 2020 · Inggris · PubMed Central

    The dose metrics and factors influencing radiation exposure for patients undergoing head, chest, and abdominal computed tomography (CT) scans were investigated for optimization of patient dose levels. The local diagnostic reference levels (DRLs) of adult CT scans performed in our hospital were…

  4. Artikel Jurnal Teks lengkap

    A CNN‐based denoising method trained with images acquired with electron density phantoms for thin‐sliced coronary artery calcium scans

    Yang, Ching‐Ching; Hou, Kuei‐Yuan

    J Appl Clin Med Phys · 2024 · Inggris · PubMed Central

    PURPOSE: This work proposed a convolutional neural network (CNN)‐based method trained with images acquired with electron density phantoms to reduce quantum noise for coronary artery calcium (CAC) scans reconstructed with slice thickness less than 3 mm. METHODS: A DenseNet model was used to estimate…

  5. Artikel Jurnal Teks lengkap

    A bias field correction workflow based on generative adversarial network for abdominal cancers treated with 0.35T MR‐LINAC

    Yang, Ching‐Ching; Yang, Hung‐Te

    J Appl Clin Med Phys · 2026 · Inggris · PubMed Central

    PURPOSE: In this study, a bias field correction workflow was proposed to improve the flexibility and generalizability of the generative adversarial network (GAN) model for abdominal cancer patients treated with a 0.35T magnetic resonance imaging linear accelerator (MR‐LINAC) system. METHODS: Model…

  6. Artikel Jurnal Teks lengkap

    Optimization of HU threshold for coronary artery calcium scans reconstructed at 0.5‐mm slice thickness using iterative reconstruction

    Hou, Kuei‐Yuan; Tsujioka, Katsumi; Yang, Ching‐Ching

    J Appl Clin Med Phys · 2019 · Inggris · PubMed Central

    PURPOSE: This work investigated the simultaneous influence of tube voltage, tube current, body size, and HU threshold on calcium scoring reconstructed at 0.5‐mm slice thickness using iterative reconstruction (IR) through multivariate analysis. Regression results were used to optimize the HU…

  7. Artikel Jurnal Teks lengkap

    Improving Image Quality of On-Board Cone-Beam CT in Radiation Therapy Using Image Information Provided by Planning Multi-Detector CT: A Phantom Study

    Yang, Ching-Ching; Chen, Fong-Lin; Lo, Yeh-Chi

    PLoS One · 2016 · Inggris · PubMed Central

    PURPOSE: The aim of this study was to improve the image quality of cone-beam computed tomography (CBCT) mounted on the gantry of a linear accelerator used in radiation therapy based on the image information provided by planning multi-detector CT (MDCT). METHODS: MDCT-based shading correction for…

  8. Artikel Jurnal Teks lengkap

    Effect of Body Mass Index in Coronary CT Angiography Performed on a 256-Slice Multi-Detector CT Scanner

    Law, Wei-Yip; Huang, Guan-Lin; Yang, Ching-Ching

    Diagnostics (Basel) · 2022 · Inggris · PubMed Central

    We aimed to investigate the effect of a patient’s body mass index (BMI) on radiation dose and image quality in prospectively ECG-triggered coronary CT angiography (CCTA) performed on a 256-slice multi-detector CT scanner. In total, 87 consecutive patients receiving CCTA examinations acquired with…

  9. Artikel Jurnal Teks lengkap

    Investigating the feasibility of generating dual‐energy CT from one 120‐kVp CT scan: a phantom study

    Huang, Wen‐Hui; Jhan, Kai‐Jie; Yang, Ching‐Ching

    J Appl Clin Med Phys · 2020 · Inggris · PubMed Central

    INTRODUCTION: This study aimed to investigate the feasibility of generating pseudo dual‐energy CT (DECT) from one 120‐kVp CT by using convolutional neural network (CNN) to derive additional information for quantitative image analysis through phantom study. METHODS: Dual‐energy scans (80/140 kVp)…

  10. Artikel Jurnal Teks lengkap

    Reducing scan time in (177)Lu planar scintigraphy using convolutional neural network: A Monte Carlo simulation study

    Yang, Ching‐Ching; Ko, Kuan‐Yin; Lin, Pei‐Yao

    J Appl Clin Med Phys · 2023 · Inggris · PubMed Central

    PURPOSE: The aim of this study was to reduce scan time in (177)Lu planar scintigraphy through the use of convolutional neural network (CNN) to facilitate personalized dosimetry for (177)Lu‐based peptide receptor radionuclide therapy. METHODS: The CNN model used in this work was based on DenseNet…

  11. Artikel Jurnal Teks lengkap

    Applying MRI Intensity Normalization on Non-Bone Tissues to Facilitate Pseudo-CT Synthesis from MRI

    Hou, Kuei-Yuan; Lu, Hao-Yuan; Yang, Ching-Ching

    Diagnostics (Basel) · 2021 · Inggris · PubMed Central

    This study aimed to facilitate pseudo-CT synthesis from MRI by normalizing MRI intensity of the same tissue type to a similar intensity level. MRI intensity normalization was conducted through dividing MRI by a shading map, which is a smoothed ratio image between MRI and a three-intensity mask…

  12. Artikel Jurnal Teks lengkap

    Evaluating auto‐contouring accuracy in reduced CT dose images for radiopharmaceutical therapies: Denoising and evaluation of (177)Lu DOTATATE therapy dataset

    Yang, Hung‐Te; Ko, Kuan‐Yin; Yang, Ching‐Ching

    J Appl Clin Med Phys · 2025 · Inggris · PubMed Central

    PURPOSE: Reducing radiation dose attributed to computed tomography (CT) may compromise the accuracy of organ segmentation, an important step in (177)Lu DOTATATE therapy that affects both activity and mass estimates. This study aimed to facilitate CT dose reduction using deep learning methods for…

  13. Artikel Jurnal Teks lengkap

    Evaluating the impact of deep learning‐based image denoising on low‐dose CT for lung cancer screening

    Chen, Shih‐Sheng; Liu, Hsiao‐Hua; Yang, Ching‐Ching

    J Appl Clin Med Phys · 2026 · Inggris · PubMed Central

    PURPOSE: Low‐dose CT (LDCT) is increasingly being adopted as a preferred method for lung cancer screening. However, the accompanying rise in image noise necessitates robust denoising strategies. Therefore, this study compared LDCT images with their denoised counterparts using objective image…

  14. Artikel Jurnal Teks lengkap

    Relationship between heart rate and optimal reconstruction phase in coronary CT angiography performed on a 256-slice multidetector CT

    Yang, Ching-Ching; Law, Wei-Yip; Lu, Kun-Mu dkk.

    Br J Radiol · 2019 · Inggris · PubMed Central

    OBJECTIVE: This study aimed to evaluate the relationship between heart rate (HR) and optimal reconstruction phase in prospectively electrocardiogram (ECG)-triggered coronary CT angiography (CCTA) performed on a newly introduced 256-slice multidetector CT (MDCT). METHODS: All the cases were selected…

  15. Artikel Jurnal Teks lengkap

    Optimizing the target detectability of cone beam CT performed in image‐guided radiation therapy for patients of different body sizes

    Yang, Ching‐Ching; Yu, Pei‐Chieh; Ruan, Jau‐Ming dkk.

    J Appl Clin Med Phys · 2018 · Inggris · PubMed Central

    PURPOSE: The target detectability of cone beam computed tomography (CBCT) performed in image‐guided radiation therapy (IGRT) was investigated to achieve sufficient image quality for patient positioning over a course of treatment session while maintaining radiation exposure from CBCT imaging as low…

  16. Artikel Jurnal Teks lengkap

    Investigating the lesion detectability of Tc‐99m planar scintigraphy acquired with LEHRS collimator for patients with different body sizes: A phantom study

    Lin, Pei‐Yao; Jhan, Kai‐Jie; Ko, Kuan‐Yin dkk.

    J Appl Clin Med Phys · 2022 · Inggris · PubMed Central

    PURPOSE: The aim of this work was to investigate the lesion detectability of Tc‐99m planar scintigraphy acquired with a low‐energy high‐resolution and sensitivity (LEHRS) collimator and processed by Clarity 2D for patients with different body sizes through phantom study. METHODS: A NEMA IEC body…

  17. Artikel Jurnal Teks lengkap

    Infant Cardiac CT Angiography with 64-Slice and 256-Slice CT: Comparison of Radiation Dose and Image Quality Using a Pediatric Phantom

    Lee, Yi-Wei; Yang, Ching-Ching; Mok, Greta S. P. dkk.

    PLoS One · 2012 · Inggris · PubMed Central

    BACKGROUND: The aims of this study were to investigate the image quality and radiation exposure of pediatric protocols for cardiac CT angiography (CTA) in infants under one year of age. METHODOLOGY/PRINCIPAL FINDINGS: Cardiac CTA examinations were performed using an anthropomorphic phantom…

  18. Artikel Jurnal Teks lengkap

    Reduction of Viral and Bacterial Activity by Using a Self-Powered Variable-Frequency Electrical Stimulation Device

    Tsai, Hsin-Yi; Lin, Yu-Hsuan; Huang, Kuo-Cheng dkk.

    Micromachines (Basel) · 2023 · Inggris · PubMed Central

    Viruses and bacteria, which can rapidly spread through droplets and saliva, can have serious effects on people’s health. Viral activity is traditionally inhibited using chemical substances, such as alcohol or bleach, or physical methods, such as thermal energy or ultraviolet-light irradiation…

  19. Artikel Jurnal Teks lengkap

    Prospectively versus Retrospectively ECG-Gated 256-Slice CT Angiography to Assess Coronary Artery Bypass Grafts — Comparison of Image Quality and Radiation Dose

    Lee, Yi-Wei; Yang, Ching-Ching; Mok, Greta S. P. dkk.

    PLoS One · 2012 · Inggris · PubMed Central

    OBJECTIVE: In this retrospective non-randomized cohort study, the image quality and radiation dose were compared between prospectively electrocardiogram (ECG)-gated axial (PGA) and retrospectively ECG-gated helical (RGH) techniques for the assessment of coronary artery bypass grafts using 256-slice…