72 hasil untuk "Defaye Pascal"
Menampilkan 41–60 · 0,85 detik · RSS
-
Artikel Jurnal Teks lengkap
Outcomes after cryoballoon ablation of paroxysmal atrial fibrillation with the PolarX or the Arctic Front Advance Pro: a prospective multicentre experience
AIMS: The aim of this study was to compare procedural efficacy and safety, including 1-year freedom from AF recurrence, between the novel cryoballoon system PolarX (Boston Scientific) and the Arctic Front Advance Pro (AFA-Pro) (Medtronic), in patients with paroxysmal AF undergoing PVI. METHODS AND…
-
Artikel Jurnal Teks lengkap
Multipoint pacing is associated with improved prognosis and cardiac resynchronization therapy response: MORE-CRT MPP randomized study secondary analyses
AIMS: Cardiac resynchronization therapy (CRT) via biventricular (BIV) pacing is indicated in patients with heart failure (HF), reduced ejection fraction, and prolonged QRS duration. Quadripolar leads and multipoint pacing (MPP) allow multiple left ventricle (LV) sites pacing. We aimed to assess the…
-
Artikel Jurnal Teks lengkap
Atrioventricular Synchrony Delivered by a Dual-Chamber Leadless Pacemaker System
BACKGROUND: A dual-chamber leadless pacemaker system has been designed for atrioventricular synchronous pacing using wireless, beat-to-beat, implant-to-implant (i2i) communication between distinct atrial and ventricular leadless pacemakers. The atrioventricular synchrony achieved across various…
-
Artikel Jurnal Teks lengkap
Battery longevity of a helix-fixation dual-chamber leadless pacemaker: results from the AVEIR DR i2i Study
AIMS: A dual-chamber leadless pacemaker (LP) system that employs distinct atrial and ventricular LP devices (ALP, VLP) has been introduced to clinical practice. Proprietary, low-energy, implant-to-implant (i2i) communication at each beat enables the devices to maintain synchronous atrioventricular…
-
Artikel Jurnal Teks lengkap
Atrioventricular synchrony maintained by a dual-chamber leadless pacemaker in real-world conditions
AIMS: A dual-chamber leadless pacemaker (LP) system relies on a beat-to-beat, wireless, implant-to-implant (i2i™) communication between implanted devices in the right atrium and right ventricle (A-to-V and V-to-A). Atrioventricular (AV) synchrony was evaluated during an ambulatory 24 h period of…
-
Artikel Jurnal Teks lengkap
How is Contact Force implemented in routine clinical practice? Results from a French National and Monaco Survey
BACKGROUND: Combination of elementary parameters (force, time, power, impedance drop) has been proposed to optimize radiofrequency (RF) delivery. They have been partially validated in clinical studies. AIMS: The aim of this study was to assess contact‐force (CF) implementation into clinical…
-
Artikel Jurnal Teks lengkap
Incidence, Characteristics, and Outcomes of Ventricular Fibrillation Complicating Acute Myocardial Infarction in Women Admitted Alive in the Hospital
BACKGROUND: Little data are available in women presenting with ventricular fibrillation (VF) in the setting of acute myocardial infarction (AMI). We assessed frequency, predictors of VF, and outcomes, with a special focus on women compared with men. METHODS AND RESULTS: Data were analyzed from the…
-
Artikel Jurnal Teks lengkap
Pre‐emptive treatment of heart failure exacerbations in patients managed with the HeartLogic™ algorithm
AIMS: Heart failure (HF) is a chronic disease affecting 64 million people worldwide and places a severe burden on society because of its mortality, numerous re‐hospitalizations and associated costs. HeartLogic™ is an algorithm programmed into implanted devices incorporating several biometric…
-
Artikel Jurnal Teks lengkap
Upgrading expandable leadless pacemakers from single- to dual-chamber
AIMS: The aim of this analysis was to evaluate the upgradeability of a single-chamber leadless pacemaker (LP) to a dual-chamber system in patients indicated for a dual-chamber pacemaker. METHODS AND RESULTS: A prospective, multicentre study evaluated the safety and performance of a dual-chamber LP…
-
Artikel Jurnal Teks lengkap
Impact and safety of remote monitoring of heart failure patients managed with the HeartLogic algorithm: the HeartLogic France Cohort Study
AIMS: HeartLogic, an algorithm in implanted devices, predicts heart failure (HF) episodes via a remotely monitored index, aiding proactive congestion treatment to prevent acute decompensation. This study assessed the efficacy and safety of pre-emptive HF management using the HeartLogic index…
-
Artikel Jurnal Teks lengkap
Primary Prevention Implantable Cardioverter Defibrillator (ICD) Therapy in Women—Data From a Multicenter French Registry
BACKGROUND: There are limited data describing sex specificities regarding implantable cardioverter defibrillators (ICDs) in the real‐world European setting. METHODS AND RESULTS: Using a large multicenter cohort of consecutive patients referred for ICD implantation for primary prevention…
-
Artikel Jurnal Teks lengkap
Impact of Body Mass Index on the Outcomes of Catheter Ablation of Atrial Fibrillation: A European Observational Multicenter Study
BACKGROUND: Outcomes of catheter ablation of atrial fibrillation (AF) are variable and the predictors of success require further elucidation since the identification of correctable risk factors could help to optimize therapy. We aimed to assess the impact of body mass index (BMI) in the overall…
-
Artikel Jurnal Teks lengkap
Real-world experience of leadless left ventricular endocardial cardiac resynchronization therapy: A multicenter international registry of the WiSE-CRT pacing system
BACKGROUND: Biventricular endocardial pacing (BiV ENDO) is a therapy for heart failure patients who cannot receive transvenous epicardial cardiac resynchronization therapy (CRT) or have not responded adequately to CRT. BiV ENDO CRT can be delivered by a new wireless LV ENDO pacing system (WiSE-CRT…
-
Artikel Jurnal Teks lengkap
Leadless Ultrasound-Based Cardiac Resynchronization System in Heart Failure
IMPORTANCE: Approximately 40% of patients with heart failure (HF) who are eligible for cardiac resynchronization therapy (CRT) either fail to respond or are untreatable due to anatomical constraints. OBJECTIVE: To assess the safety and efficacy of a novel, leadless, left ventricular (LV)…
-
Artikel Jurnal Teks lengkap
Catheter Ablation of Atrial Fibrillation in Patients with Previous Lobectomy or Partial Lung Resection: Long-Term Results of an International Multicenter Study
Introduction: Data regarding the efficacy of catheter ablation in patients with atrial fibrillation (AF) and patients’ previous history of pulmonary lobectomy/pneumonectomy are scanty. We sought to evaluate the efficacy and long-term follow-up of catheter ablation in this highly selected group of…
-
Artikel Jurnal Teks lengkap
European Society of Cardiology Quality Indicators for the care and outcomes of cardiac pacing: developed by the Working Group for Cardiac Pacing Quality Indicators in collaboration with the European Heart Rhythm Association of the European Society of Cardiology
AIMS: To develop a suite of quality indicators (QIs) for the evaluation of the care and outcomes for adults undergoing cardiac pacing. METHODS AND RESULTS: Under the auspice of the Clinical Practice Guideline Quality Indicator Committee of the European Society of Cardiology (ESC), the Working Group…
-
Artikel Jurnal Teks lengkap
Management of patients with transvalvular right ventricular leads undergoing transcatheter tricuspid valve interventions: a scientific statement of the European Heart Rhythm Association and the European Association of Percutaneous Cardiovascular Interventions of the ESC endorsed by the Heart Rhythm Society, the Asian Pacific Heart Rhythm Society and the Canadian Heart Rhythm Society
Up to one-third of patients referred for transcatheter tricuspid valve intervention (TTVI) have a transvalvular pacemaker (PPM) or implantable cardioverter-defibrillator (ICD) lead in place. Both the electrophysiology and interventional cardiology communities have been alerted to the complexity of…
Juga tersedia di: PubMed Central
-
Artikel Jurnal Teks lengkap
Amplified sinus-P-wave analysis predicts outcomes of cryoballoon ablation in patients with persistent and long-standing persistent atrial fibrillation: A multicentre study
INTRODUCTION: Outcomes of catheter ablation for non-paroxysmal atrial fibrillation (AF) remain suboptimal. Non-invasive stratification of patients based on the presence of atrial cardiomyopathy (ACM) could allow to identify the best responders to pulmonary vein isolation (PVI). METHODS…
-
Artikel Jurnal Teks lengkap
Real-world experience with the pentaspline pulsed field ablation system: one-year outcomes of the FARADISE registry
AIMS: Clinical studies with protocol-mandated workflow and monitoring have analysed performance of pulsed field ablation (PFA) for treating atrial fibrillation (AF). The FARADISE registry captures global use of the pentaspline PFA catheter in real-world clinical practice with a follow-up of 3…