41 results for "Defaye, Pascal"
Showing 1–20 · 0.48 seconds · RSS
-
Journal Article Full text
Jailed or freed? The lead dilemma in transcatheter tricuspid valve replacement
-
Journal Article Full text
Deep sedation for pulsed field ablation by electrophysiology staff: can and should we do it?
-
Journal Article Full text
Mitral valve perforation after left lateral accessory pathway ablation: a case report
BACKGROUND: Radiofrequency catheter ablation is considered to be a relatively safe procedure. This is an unusual case report in which severe mitral regurgitation was occurred after left lateral accessory pathway radiofrequency catheter ablation. CASE PRESENTATION: A 15-year-old man without…
-
Journal Article Full text
Cardiac implantable electronic devices’ longevity: A novel modelling tool for estimation and comparison
AIMS: Generator longevity is the key issue for patients, and is also important for payers, yet implanters of Cardiac Implantable Electronic Devices (CIEDs) face a challenge when selecting the appropriate device since battery longevity is only known for previous generation devices and whilst…
-
Journal Article Full text
Severe acute kidney injury related to haemolysis after pulsed field ablation for atrial fibrillation
AIMS: Pulsed field ablation (PFA) has been proposed as a novel alternative to radiofrequency (RF) and cryoablation in the treatment of atrial fibrillation (AF). Following the occurrence of two cases of acute kidney injury (AKI) secondary to haemolysis after a PFA procedure, we evaluated haemolysis…
-
Journal Article Full text
Cardiac pacing and lead devices management: 25 years of research at EP Europace journal
AIMS: Cardiac pacing represents a key element in the field of electrophysiology and the treatment of conduction diseases. Since the first issue published in 1999, EP Europace has significantly contributed to the development and dissemination of the research in this area. METHODS: In the last 25…
-
Journal Article Full text
A surgical calm to the storm: managing refractory electrical storms with bilateral thoracoscopic sympathectomy
OBJECTIVES: Refractory electrical storms (ES) present a significant challenge in patients with structural heart disease, often persisting despite optimal medical therapy, catheter ablation, and ICD therapy. This study evaluates the efficacy and safety of bilateral thoracoscopic sympathectomy (BCSD)…
-
Journal Article Full text
Impact of GLP-1 Receptor Agonist Therapy on Atrial Fibrillation Recurrence After Catheter Ablation in Obese Patients: A Real-World Data Analysis
BACKGROUND: GLP-1 (glucagon-like peptide-1) receptor agonists (GLP-1RAs), initially developed for glycemic control in type 2 diabetes, have shown cardiometabolic benefits including weight loss, improved endothelial function, and reduced inflammation. Recent data suggest potential anti-arrhythmic…
-
Journal Article Full text
Safety and success of transvenous lead extraction using excimer laser sheaths: a meta-analysis of over 1700 patients
AIMS: While numerous studies have demonstrated favourable safety and efficacy of the excimer laser sheath for transvenous lead extraction (TLE) in smaller cohorts, comprehensive large-scale investigations with contemporary data remain scarce. This study aims to evaluate the safety and performance…
-
Journal Article Full text
Filtering of remote monitoring alerts transmitted by cardiac implantable electronic devices and reclassification of atrial fibrillation events by a new algorithm
BACKGROUND: Cardiac implantable electronic devices (CIEDs) are an important means of atrial fibrillation (AF) detection. However, the AF burden measurements and notifications transmitted by CIEDs are not directly related to the clinical classification of paroxysmal, persistent, or permanent AF…
-
Journal Article Full text
Dynamic changes in nocturnal heart rate predict short-term cardiovascular events in patients using the wearable cardioverter-defibrillator: from the WEARIT-France cohort study
AIMS: While elevated resting heart rate measured at a single point of time has been associated with cardiovascular outcomes, utility of continuous monitoring of nocturnal heart rate (NHR) has never been evaluated. We hypothesized that dynamic NHR changes may predict, at short term, impending…
-
Journal Article Full text
Role of the Pharmacist in Supporting the Use of Connected Health Devices: Example of Connected Watches
The use of Connected Medical Devices (CMDs) is growing significantly throughout the world. Although they are not dispensed in pharmacies and are not part of the pharmacy-only drug dispensing system, clinical pharmacists must be able to support patients in the use of these new technologies, which…
-
Journal Article Full text
Management of Rhythm and Conduction Disorders in Cardiac Amyloidosis
BACKGROUND: Cardiac amyloidosis (CA) is an increasingly recognized cardiomyopathy with an associated risk of arrhythmias and conduction disorders; however, managing arrhythmias and conductive disorders remains largely undefined. OBJECTIVES: This study aims to gather French expert experience on…
-
Journal Article Full text
A leadless pacemaker in the real‐world setting: Patient profile and performance over time
BACKGROUND: While prior Micra trials demonstrated a high implant success rate and favorable safety and efficacy results, changes in implant populations and safety over time is not well studied. The objective of this analysis was to report the performance of Micra in European and Middle Eastern…
-
Journal Article Full text
Validation Against Polysomnography of a Transthoracic Impedance Sensor for Screening of Sleep Apnea in Heart Failure Patients: A Pooled Analysis of AIRLESS and UPGRADE
Background/Introduction: Cardiac implantable electronic devices and their integrated thoracic impedance sensors have been used to detect sleep apnea for over a decade now. Despite their usage in daily clinical practice, there are only limited data on their diagnostic accuracy. Methods: AIRLESS and…