31 hasil untuk "Liebert, Adam"
Menampilkan 1–20 · 0,00 detik · RSS
-
Artikel Jurnal Teks lengkap
Method to improve the depth sensitivity of diffuse reflectance measurements to absorption changes in optically turbid medium
We have studied the spatial distributions of the sensitivity of time-resolved near-infrared diffuse reflectance measurement. Sensitivity factors representing a change of parameters of a measured optical signal induced by absorption perturbation in a certain voxel of the medium were simulated using…
-
Artikel Jurnal Teks lengkap
Lock-in functional near-infrared spectroscopy for measurement of the haemodynamic brain response
Here we show a method of the lock-in amplifying near-infrared signals originating within a human brain. It implies using two 90-degree rotated source-detector pairs fixed on a head surface. Both pairs have a joint sensitivity region located towards the brain. A direct application of the lock-in…
-
Artikel Jurnal Teks lengkap
Oxygen-dependent functional brain haemodynamic response
The influence of hypoxia - a condition where tissues are under oxygen deficiency - on the human brain under functional load has not been fully understood yet. This study aims to analyse the effects of hypoxia on the brain’s haemodynamic response under visual stimulation, using the in-house…
-
Artikel Jurnal Teks lengkap
Multiwavelength time-resolved near-infrared spectroscopy of the adult head: assessment of intracerebral and extracerebral absorption changes
An optical technique based on diffuse reflectance measurement combined with indocyanine green (ICG) bolus tracking is extensively tested as a method for the clinical assessment of brain perfusion at the bedside. We report on multiwavelength time-resolved diffuse reflectance spectroscopy…
-
Artikel Jurnal Teks lengkap
Depth-selective data analysis for time-domain fNIRS: moments vs. time windows
Time-domain measurements facilitate the elimination of the influence of extracerebral, systemic effects, a key problem in functional near-infrared spectroscopy (fNIRS) of the adult human brain. The analysis of measured time-of-flight distributions of photons often relies on moments or time windows…
-
Artikel Jurnal Teks lengkap
Performance of measurands in time-domain optical brain imaging: depth selectivity versus contrast-to-noise ratio
Time-domain optical brain imaging techniques introduce a number of different measurands for analyzing absorption changes located deep in the tissue, complicated by superficial absorption changes and noise. We implement a method that allows analysis, quantitative comparison and performance ranking…
-
Artikel Jurnal Teks lengkap
Time-domain diffuse correlation spectroscopy at large source detector separation for cerebral blood flow recovery
Time-domain diffuse correlation spectroscopy (td-DCS) enables the depth discrimination in tissue’s blood flow recovery, considering the fraction of photons detected with higher time of flight (TOF) and longer pathlength through the tissue. However, the recovery result depends on factors such as the…
-
Artikel Jurnal Teks lengkap
Two-layered blood-lipid phantom and method to determine absorption and oxygenation employing changes in moments of DTOFs
Near-infrared spectroscopy (NIRS) is an established technique for measuring tissue oxygen saturation (StO(2)), which is of high clinical value. For tissues that have layered structures, it is challenging but clinically relevant to obtain StO(2) of the different layers, e.g. brain and scalp. For…
-
Artikel Jurnal Teks lengkap
Approaches for modelling autocorrelation function and data processing in time-domain diffuse correlation spectroscopy
Time-domain diffuse correlation spectroscopy (TD-DCS) is a non-invasive optical technique for measuring tissue blood flow. Recovering the blood flow index (αD(b)) requires accurate modelling of the normalised electric field autocorrelation function (g(1)), and an optimised data processing approach…
-
Artikel Jurnal Teks lengkap
Neurotoxic effects of indocyanine green -cerebellar granule cell culture viability study
The aim of this study was to examine neurotoxicity indocyanine green (ICG). We assessed viability of primary cerebellar granule cell culture (CGC) exposed to ICG to test two mechanisms that could be the first triggers causing neuronal toxicity: imbalance in calcium homeostasis and the degree of…
-
Artikel Jurnal Teks lengkap
Frequency analysis of oscillations in cerebral hemodynamics measured by time domain near infrared spectroscopy
In this paper, we propose the application of time-domain near-infrared spectroscopy to the assessment of oscillations in cerebral hemodynamics. These oscillations were observed in the statistical moments of the distributions of time of flight of photons (DTOFs) measured on the head. We analyzed the…
-
Artikel Jurnal Teks lengkap
Prolonged Postocclusive Hyperemia Response in Patients with Normal-Tension Glaucoma
BACKGROUND: It is believed that endothelial dysfunction may be a link between systemic and ocular dysregulation in glaucoma. The aim of this study was to evaluate peripheral vascular reactive hyperemia in response to occlusion test and to correlate peripheral vascular findings with retrobulbar…
-
Artikel Jurnal Teks lengkap
Time-domain diffuse correlation spectroscopy (TD-DCS) for noninvasive, depth-dependent blood flow quantification in human tissue in vivo
Monitoring of human tissue hemodynamics is invaluable in clinics as the proper blood flow regulates cellular-level metabolism. Time-domain diffuse correlation spectroscopy (TD-DCS) enables noninvasive blood flow measurements by analyzing temporal intensity fluctuations of the scattered light. With…
-
Artikel Jurnal Teks lengkap
Depth-selective method for time-domain diffuse reflectance measurements: validation study of the dual subtraction technique
Research on the spatial distribution of sensitivity of time-domain near infrared diffuse reflectance measurement is reported in this paper. The main objective of the investigation is to validate theoretically calculated sensitivity profiles for a measurement geometry with two detectors and two…
-
Artikel Jurnal Teks lengkap
Subtraction-based approach for enhancing the depth sensitivity of time-resolved NIRS
The aim of this study was to evaluate enhancing of the depth sensitivity of time-resolved near-infrared spectroscopy with a subtraction-based approach. Due to the complexity of light propagation in a heterogeneous media, and to prove the validity of the proposed method in a heterogeneous turbid…
-
Artikel Jurnal Teks lengkap
Coupling of Oxy- and Deoxyhemoglobin concentrations with EEG rhythms during motor task
A relationship between the brain rhythmic activity and the hemodynamic response was studied using the simultaneous measurement of electroencephalogram (EEG) and the functional near-infrared spectroscopy (fNIRS) during a motor task (self-paced right finger movements) for 10 subjects. An EEG…
-
Artikel Jurnal Teks lengkap
Depth-resolved assessment of changes in concentration of chromophores using time-resolved near-infrared spectroscopy: estimation of cytochrome-c-oxidase uncertainty by Monte Carlo simulations
Time-resolved near-infrared spectroscopy (TR-NIRS) measurements can be used to recover changes in concentrations of tissue constituents ([Formula: see text]) by applying the moments method and the Beer-Lambert law. In this work we carried out the error propagation analysis allowing to calculate the…
-
Artikel Jurnal Teks lengkap
Self-calibrating time-resolved near infrared spectroscopy
Time-resolved near infrared spectroscopy is considered to be a gold standard technique when measuring absolute values of tissue optical properties, as it provides separable and independent information about both tissue absorption and scattering. However, time-resolved instruments require an…
-
Artikel Jurnal Teks lengkap
Influence of contrast-reversing frequency on the amplitude and spatial distribution of visual cortex hemodynamic responses
Visual stimulation is one of the most commonly used paradigms for cerebral cortex function investigation. Experiments typically involve presenting to a volunteer a black-and-white checkerboard with contrast-reversing at a frequency of 4 to 16 Hz. The aim of the present study was to investigate the…