22 results for "Daisuke Anzai"
Showing 1–20 · 0.83 seconds · RSS
-
Journal Article Full text
Driver’s ECG Signal Detection and Transmission by Impulse-Radio-Based Human Body Communication Technology
In this study, we developed a wearable electrocardiogram(ECG) sensor with human body communication (HBC) tech-nology for vital data transmission in a car. The ECG signals were modulated with wideband pulse signals between 10 and 60 MHz based on an impulse radio (IR) scheme, which provides a data…
-
Journal Article
Common-mode noise cancellation circuit for wearable ECG
Wearable electrocardiogram (ECG) is attracting much attention for monitoring heart diseases in healthcare and medical applications. However, an imbalance usually exists between the contact resistances of sensing electrodes, so that a common mode noise caused by external electromagnetic field can be…
-
Journal Article
Blood pressure estimation system using human body communication-based electrocardiograph and photoplethysmography
In order to realise low-load cuffless and continuous blood pressure measurement in daily life, the authors developed a blood pressure estimation system combining human body communication-based wearable electrocardiograph and reflectance photoplethysmography. The principle is based on a relationship…
-
Journal Article
Motion artefact removals for wearable ECG using stationary wavelet transform
Wearable Electrocardiogram (ECG) is attracting much attention in daily healthcare applications. From the viewpoint of long-term use, it is desired that the electrodes are non-contact with the human body. In this study, the authors propose an algorithm using the stationary wavelet transform (SWT) to…
-
Journal Article
Wireless Control of Robotic Artificial Hand Using Myoelectric Signal Based on Wideband Human Body Communication
A Myoelectric hand is a robotic artificial hand controlled by myoelectric signals and driven by motors. The myoelectric signals are detected on the arm and sent to the motor controller by wire for driving the artificial hand. However, from the point of view of convenience, wireless connection…
-
Journal Article
Weight optimization of MIMO-UWB distributed beamforming for implant communications
Abstract This paper discussed a frequency-dependent distributed beamforming technique to improve the reliability in implant multiple-input multiple-output (MIMO)-ultra wideband (UWB) communications. To realize distributed beamforming for implant MIMO-UWB systems, we propose an optimization method…
-
Journal Article
Localization Method for Implant Devices Using Electromagnetic Scattering Based on Sparse Reconstruction
Herein, we propose a localization method for implant devices using electromagnetic scattering based on sparse reconstruction. We define the product of the total electric field and the complex relative permittivity as a new unknown variable, which is expected to be sparse. Computer simulations are…
-
Journal Article Full text
Ambient Environmental Parameter Estimation for Reliable Diffusive Molecular Communications
Molecular communication is a promising communication technology that uses biomolecules such as proteins and ions to establish a communication link between nanoscale devices. In diffusive molecular communication, which uses diffusion characteristics of transfer molecules, the diffusion mechanism is…
-
Journal Article Full text
Common-Mode Noise Reduction in Noncontact Biopotential Acquisition Circuit Based on Imbalance Cancellation of Electrode-Body Impedance
Biopotential sensing technology with electrodes has a great future in medical treatment and human—machine interface, whereas comfort and longevity are two significant problems during usage. Noncontact electrode is a promising alternative to achieve more comfortable and long term biopotential signal…
-
Journal Article
Body Area Network User Mobility Control for Optimal Position for Maximizing Throughput in BAN Ad Hoc Networks
In this study, we propose and evaluate a centralized mobility control method that determines the optimal positions of BAN (Body Area Network) nodes to maximize the network throughput in BAN ad hoc networks. Recently, BAN ad hoc networks using Wi-Fi connections between BAN nodes have gained…
-
Journal Article
Mobility Control for Optimal Position of Body Area Network User for High Communication Quality in BAN Mesh Networks
In this paper, we propose a user mobility control method that improves data application throughput by relocating the Body Area Network (BAN) node to an optimal position where the throughput of intra-BAN (On-Body) and inter-BAN (Inter-Sink) communication topologies are compatible to the BAN mesh…
-
Journal Article Full text
Systematic Performance Evaluation of a Novel Optimized Differential Localization Method for Capsule Endoscopes
Capsule endoscopy is a well-established diagnostic tool for the gastrointestinal tract. However, the reliable tracking of capsule endoscopes needs further investigation. Recently, the static magnetic differential method for the localization of capsule endoscopes has shown promising results. This…
-
Journal Article Full text
Heat Stroke Prevention in Hot Specific Occupational Environment Enhanced by Supervised Machine Learning with Personalized Vital Signs
Recently, wet-bulb globe temperature (WBGT) has attracted a lot of attention as a useful index for measuring heat strokes even when core body temperature cannot be available for the prevention. However, because the WBGT is only valid in the vicinity of the WBGT meter, the actual ambient heat could…
-
Journal Article Full text
Preliminary Quantitative Evaluation of the Optimal Colour System for the Assessment of Peripheral Circulation from Applied Pressure Using Machine Learning
Peripheral circulatory failure refers to a condition in which the blood flow through superficial capillaries is markedly reduced or completely occluded. In clinical practice, nurses strictly adhere to regular repositioning protocols to prevent peripheral circulatory failure, during which the skin…
-
Journal Article
Peak-Forming-Enhanced Electromagnetic Imaging Method for Implantable Device Localization
To improve the quality of medical treatment using implantable devices, accurate location information for implantable devices must be acquired and reliable implant communications for vital data transmission must be ensured. This paper focuses on an electromagnetic (EM) imaging-based method using…
-
Journal Article Full text
A Feasibility Study of a Respiratory Rate Measurement System Using Wearable MOx Sensors
Accurately obtaining a patient’s respiratory rate is crucial for promptly identifying any sudden changes in their condition during emergencies. Typically, the respiratory rate is assessed through a combination of impedance change measurements and electrocardiography (ECG). However, impedance…
-
Journal Article
Perfect pulse filtering under simultaneous incidence at the same frequencies with waveform-selective metasurfaces
We present a new concept of metasurface filters to preferentially extract pulsed waveforms at a constant frequency from a complex superimposed input signal. This filtering capability is realized using circuit-based metasurfaces, denoted waveform-selective metasurfaces, that behave according to the…
-
Journal Article
Influence of population density, temperature, and absolute humidity on spread and decay durations of COVID-19: A comparative study of scenarios in China, England, Germany, and Japan
In this study, we analyzed the spread and decay durations of the COVID-19 pandemic in several cities of China, England, Germany, and Japan, where the first wave has undergone decay. Differences in medical and health insurance systems, as well as in regional policies incommoded the comparison of the…
-
Journal Article Full text
Reliable Stenosis Detection Based on Thrill Waveform Analysis Using Non-Contact Arteriovenous Fistula Imaging
Hemodialysis therapy is an extracorporeal circulation treatment that serves as a substitute for renal function. In Japan, patients receive this efficient four-hour treatment, three times per week, allowing them to maintain a social life nearly equivalent to that of healthy individuals. Before the…
-
Journal Article
Inkjet printed intelligent reflecting surface for indoor applications
Abstract A passive, low‐cost, paper‐based intelligent reflecting surface (IRS) is designed to reflect a signal in a desired direction to overcome non‐line‐of‐sight scenarios in indoor environments. The IRS is fabricated using conductive silver ink printed on paper with a specific nanoparticle…