29 results for "Keyvan Jabbari"
Showing 1–20 · 0.18 seconds · RSS
-
Journal Article
A fast Monte Carlo code for proton transport in radiation therapy based on MCNPX
An important requirement for proton therapy is a software for dose calculation. Monte Carlo is the most accurate method for dose calculation, but it is very slow. In this work, a method is developed to improve the speed of dose calculation. The method is based on pre-generated tracks for particle…
-
Journal Article
Evaluation of Setup Errors in Two Radiotherapy Centers from a Physicist’s Point of View
Purpose- The setup verification is one of the important issues in radiation therapy. In this study, an experienced physicist evaluated the setup of the patients during treatments where many unexpected errors were observed. Methods- The physicist spent few hours a week in the treatment room and…
-
Journal Article
Evaluation of various boluses in dose distribution for electron therapy of the chest wall with an inward defect
Delivering radiotherapy to the postmastectomy chest wall can be achieved using matched electron fields. Surgical defects of the chest wall change the dose distribution of electrons. In this study, the improvement of dose homogeneity using simple, nonconformal techniques of thermoplastic bolus…
-
Journal Article
Evaluation and benchmarking of EGSnrc code in the simulation of 18 MV photon beam produced by Siemens Oncor® linear accelerator
Introdution: The aim of this study was to evaluate and benchmark EGSnrc code in the simulation of 18 MV photon beam produced by Siemens Oncor® linear accelerator. Methods: This study was conducted in a comparative and simulation based on experience method. The Beamnrc code was used to model the…
-
Journal Article
بهینهسازی کیفیت الکتروندرمانی دیوارهی قفسهی سینهی ناهموار بعد از ماستکتومی
مقدمه: الکتروندرمانی، مزیت افت سریع دوز در عمق بعد از نقطهی 80 درصد منحنی دوز- عمق دارد. شکل منحصر به فرد منحنیهای ایزودوز پرتو الکترون و انحنای سطح قفسهی سینه، الکتروندرمانی این ناحیه را پیچیده میسازد. بولوس مادهای است که شکلدهی به پوشش دوز را میسر میسازد و ناهمواریهای سطوح را جبران…
-
Journal Article Full text
The Quality Control of Intensity Modulated Radiation Therapy (IMRT) for ONCOR Siemens Linear Accelerators Using Film Dosimetry
Introduction Intensity Modulated Radiation Therapy (IMRT) has made a significant progress in radiation therapy centers in recent years. In this method, each radiation beam is divided into many subfields that create a field with a modulated intensity. Considering the complexity of this method, the…
-
Journal Article
Calculation of excess dose to the eye phantom due to a distanced shielding for electron therapy in head and neck cancers
For superficial lesions, the electrons may be used for radiation therapy. The high energy photons and electrons are produced by a Linear accelerator (Linac). Many of electron fields need the shielding of normal or critical organs. The electron shields are usually lead slabs with few millimeter…
-
Journal Article
Evaluation of Effective Parameters on Quality of Magnetic Resonance Imaging-computed Tomography Image Fusion in Head and Neck Tumors for Application in Treatment Planning
Background: In radiation therapy, computed tomography (CT) simulation is used for treatment planning to define the location of tumor. Magnetic resonance imaging (MRI)-CT image fusion leads to more efficient tumor contouring. This work tried to identify the practical issues for the combination of CT…
-
Journal Article
Optimizing of the Tangential Technique and Supraclavicular Fields in 3 Dimensional Conformal Radiation Therapy for Breast Cancer
Radiotherapy plays an essential role in the management of breast cancer. Three-dimensional conformal radiation therapy (3D-CRT) is applied based on 3D image information of anatomy of patients. In 3D-CRT for breast cancer one of the common techniques is tangential technique. In this project, various…
-
Journal Article
Designing and dosimetry of a shield for photon fields of radiation therapy in oral cavity cancer
The cancer of oral cavity is related to lesions of mucous membrane of tongue and gum that can be treated with radiation therapy. A lateral photon field can be used to treat this kind of tumor, which has a side-effect on normal tissue in the opposite side of the oral cavity. In this study the…
-
Journal Article
Development and Implementation of the Convolution Method for Photon Dose Calculation in Radiation Therapy
Background: One of the most widely used methods in cancer treatment is radiation therapy. In radiation therapy, the goal is to deliver maximum dose to the cancerous tissue and the least amount to adjacent normal tissue. Therefore, it is important to calculate radiation doses received by different…
-
Journal Article
Evaluation and Comparison of Various 3-D Conformal and Intensity-Modulated Radiotherapy Techniques for Treatment of Parotid Gland Cancer
Background: In this study, a comparison between various types of radiotherapy treatment for parotid gland cancer was performed to achieve the optimal treatment technique. Methods: Treatment planning and countering performed with TiGRT software for 15 patents with parotid gland cancer. Six…
-
Journal Article
Evaluation and Optimization of Absorbed Dose to the Eye Lens in Various Intensity-Modulated Radiation Therapy (IMRT) Techniques for Treatment of Frontal Area Tumors
Background: In this study, a comparison was performed between various intensity-modulated radiation therapy (IMRT) techniques for treatment of frontal area tumors in order to achieve the optimal treatment technique considering absorbed dose to the eye lens. Methods: Treatment planning and…
-
Journal Article
Dosimetry and evaluating the effect of treatment parameters on the leakage of multi leaf collimators in ONCOR linear accelerators
Background: One of the standard equipment in medical linear accelerators is multi-leaf collimators (MLCs); which is used as a replacement for lead shielding. MLC's advantages are a reduction of the treatment time, the simplicity of treatment, and better dose distribution. The main disadvantage of…
-
Journal Article
Measurement of Photoneutron Dose in the Linear Accelerator at the Radiation Therapy Section of Seyed-Al-Shohada Hospital, Isfahan, Iran
Background: Radiation therapy with linear accelerators (Linac) is one of the efficient techniques for cancer treatment. However, the interaction between high energy photons and various materials on the Linac's head produces photoneutron contamination. Total flux of neutrons per unit of radiation in…
-
Journal Article
Evaluation and Comparison of Various Treatment Plannings for Ovarian Cancer Involving the Abdominal Area
Background: Radiation therapy is used to treat and control advanced ovarian cancer with spread to abdominal peritoneum. In this study, a comparison between various plans of radiation therapy within the abdomen and pelvis was performed in order to achieve an effective treatment response. Methods…
-
Journal Article
Markerless Respiratory Tumor Motion Prediction Using an Adaptive Neuro-fuzzy Approach
Background: Accurate delivery of the prescribed dose to moving lung tumors is a key challenge in radiation therapy. Tumor tracking involves real-time specifying the target and correcting the geometry to compensate for the respiratory motion, that's why tracking the tumor requires caution. This…
-
Journal Article
Comparison of electromagnetic and hadronic models generated using Geant 4 with antiproton dose measured in CERN
After proposing the idea of antiproton cancer treatment in 1984 many experiments were launched to investigate different aspects of physical and radiobiological properties of antiproton, which came from its annihilation reactions. One of these experiments has been done at the European Organization…
-
Journal Article
Investigation and Comparison of Coplanar Versus Noncoplanar Intensity-Modulated Radiation Therapy (IMRT) Techniques in Glioblastoma Multiforme Tumors
Background: This study aimed to make a comparison among 4 coplanar and noncoplanar intensity-modulated radiation therapy (IMRT) techniques in glioblastoma multiforme (GBM) tumors, to achieve an optimal treatment technique considering the absorbed doses of organs at risk. Methods: Treatment planning…
-
Journal Article
Evaluation of a Treatment Planning System for Applying the Effect of Titanium Clips on Isodosedistribution in Radiation Therapy of Colorectal Cancer
Background: In laparoscopy of colorectal tumors, titanium clips are used to close the surgery site. For post-operation treatment with radiation, the clips might change the dose distribution. In this study, the effect of titanium clips in isodose distribution of 6- and 18-MV photons was evaluated…