6 hasil untuk "Stephan Chalup"
Menampilkan 1–6 · 0,19 detik · RSS
-
Artikel Jurnal Teks lengkap
Semi-Supervised Manifold Alignment Using Parallel Deep Autoencoders
The aim of manifold learning is to extract low-dimensional manifolds from high-dimensional data. Manifold alignment is a variant of manifold learning that uses two or more datasets that are assumed to represent different high-dimensional representations of the same underlying manifold. Manifold…
-
Artikel Jurnal Teks lengkap
Optimisation of 2D U-Net Model Components for Automatic Prostate Segmentation on MRI
In this paper, we develop an optimised state-of-the-art 2D U-Net model by studying the effects of the individual deep learning model components in performing prostate segmentation. We found that for upsampling, the combination of interpolation and convolution is better than the use of transposed…
-
Artikel Jurnal
Classifying coke using CT scans and landmark multidimensional scaling
Abstract One factor that limits development of fundamental research on the influence of coke microstructure on its strength is the difficulty in quantifying the way that microstructure is both classified and distributed in three dimensions. To support such fundamental studies, this study evaluated…
-
Artikel Jurnal
Cross‐continental zero‐shot anuran call classification with CLAP and denoising‐based synthetic embedding generation
Abstract Using machine learning models to classify bioacoustic signals of animal species is increasingly important for conservation monitoring because manual expert labelling is time‐consuming and tedious. Monitoring endangered species is particularly challenging because these species are rare…
-
Artikel Jurnal
Harnessing edge computing and citizen science: A new prototype design for continental‐scale acoustic monitoring in Australia and beyond
Abstract Inadequate monitoring of biodiversity is a characteristic of conservation the world over. The potential of acoustic monitoring is compelling, although the challenges remain substantial. Effective solutions require transdisciplinary collaboration among stakeholders, a focus on open‐source…
-
Artikel Jurnal
Bulk Anatomical Density Based Dose Calculation for Patient-Specific Quality Assurance of MRI-Only Prostate Radiotherapy
Prostate cancer treatment planning can be performed using magnetic resonance imaging (MRI) only with sCT scans. However, sCT scans are computer generated from MRI data and therefore robust, efficient, and accurate patient-specific quality assurance methods for dosimetric verification are required…