708 hasil
Menampilkan 1–20 · 0,38 detik · RSS
The Journal of Indian Prosthodontic Society
Scopus
ISSN 0972-4052 · Wolters Kluwer Medknow Publications · 708 artikel di indeks
-
Artikel Jurnal
Longitudinal assessment of cytotoxicity and cytomorphological changes in buccal mucosa exposed to dental laboratory chemicals
Aim: To assess the cytotoxicity and cytomorphological changes in the buccal mucosa cells of 1st year dental students (DS) and dental technicians (DTs) upon exposure to laboratory chemicals. Settings and Design: This observational longitudinal cohort and cross-sectional study was conducted at the…
-
Artikel Jurnal
A comparative evaluation of the marginal fit of dental copings fabricated by direct metal laser sintering and lost wax technique with two different finish lines – An in vitro study
Aim: The purpose of this in vitro study was to compare the marginal fit of dental copings fabricated by direct metal laser sintering (DMLS) and the lost wax technique with two different finish lines. Settings and Design: The study followed an in vitro experimental design. Materials and Methods: Two…
-
Artikel Jurnal
Impact of repeated usage of two different scan bodies on the accuracy of implant position transfer: An in vitro study
Aim: To evaluate and compare the effect of repeated sterilization cycles on linear, angular, and diameter changes, and overall implant position transfer accuracy of titanium and polyetheretherketone (PEEK) scan bodies. Settings and Design: An in vitro study. Materials and Methods: An in vitro study…
-
Artikel Jurnal
Comparative evaluation of effect of rescanning and cut out & stitching with uninterrupted single scan on the accuracy of digital impressions - An in vitro study
Aim: The purpose of this study is to evaluate the accuracy of digital impressions (DIs) subjected to rescanning, cutout, and stitching procedures compared to an uninterrupted single scan. Special focus on comparing the effects of these interventions on edentulous regions versus prepared abutment…
-
Artikel Jurnal
Assessment of swallowing and suprahyoid muscle activity in completely edentulous patients before and after rehabilitation with complete dentures
Aim: To assess swallowing status using jaw opening force (JOF) and the electromyographic (EMG) activity of the suprahyoid muscles during swallowing in complete denture patients before and after rehabilitation. Setting and Design: The Study design was a prospective clinical study conducted at Sri…
-
Artikel Jurnal
Assessment of psychosocial reintegration following prosthetic rehabilitation using Psychosocial Impact of Assistive Devices Scale: A case series
Background: Loss of facial structures due to trauma, congenital anomalies, or ablative surgery induces profound psychosocial consequences that impact beyond functional impairment. While rehabilitation with advanced prosthetic materials have improved esthetics and comfort, standardized measurement…
-
Artikel Jurnal
Two-piece magnet-retained silicone lip prosthesis in a mandibulectomy patient with lower lip defect following oncologic resection: A clinical case report
Lower lip defects after oncologic resection can severely affect oral competence, speech, esthetics, and psychosocial well-being. Surgical reconstruction alone may not fully restore dynamic perioral function, requiring adjunctive prosthetic rehabilitation. A 58-year-old male with right lower…
-
Artikel Jurnal
Effect of patient position on digitally recorded interocclusal distance in prepared teeth: A computer-aided design and manufacturing-based evaluation
Aim: Accurate recording of interocclusal relationships is critical for the success of prosthodontic restorations fabricated using digital workflows. Although intraoral scanners have improved the precision of occlusal recording, clinical factors such as patient positioning during scanning may…
-
Artikel Jurnal
Impact of biomaterials on intra-sinus bone changes around dental implants following indirect sinus augmentation: A randomized clinical trial
Aim: This study aimed to evaluate and compare the effect of different biomaterials – without graft, venous blood, injectable platelet-rich fibrin (i-PRF), and synthetic graft on peri-implant intra-sinus bone changes around dental implants following indirect sinus lift using the Crestal Approach…
-
Artikel Jurnal
Effect of glycerol-assisted ultraviolet postcuring duration on residual monomer release from 3D-printed denture base resins
Aim: The widespread use of printable resins contrasts with the limited evaluation of residual monomer release, that remains a significant concern for biocompatibility. Fewer studies estimated the monomer releases in printable denture base resins. The study evaluated the effect of glycerol-assisted…
-
Artikel Jurnal
Association of menopausal status and genetic polymorphisms with early crestal bone loss around dental implants: A prospective observational study
Aim: Menopause associated estrogen deficiency affects bone metabolism and may increase peri implant bone resorption. Genetic polymorphisms in inflammatory and bone related genes may further influence implant outcomes. This study evaluated the association between gene polymorphisms and peri implant…
-
Artikel Jurnal
Effects of chemical surface treatments on the shear bond strength between polyetheretherketone and veneering composite resin: An in vitro study
Aim: To examine the effects of different chemical surface treatments on the shear bond strength (SBS) between milled PEEK and veneering composite resin. Settings and Design: This was an in vitro comparative study. Materials and Methods: Sixty PEEK discs were assigned to four groups (n = 15): no…
-
Artikel Jurnal
Correlation between index finger length and occlusal vertical dimension in dentate adults of different facial forms in West Bengal population: A cross-sectional study
Aim: The aim of the study was to investigate the correlation between index finger length and occlusal vertical dimension (OVD) across different facial morphological types in dentate adults of West Bengal population. Settings and Design: A cross-sectional observational study was conducted among 212…
-
Artikel Jurnal
Comparative evaluation of 2-step and 3-step polishing systems on the surface roughness and flexural strength of lithium disilicate: An in vitro study
Aim: The aim of this in vitro study was to investigate the effects of 2-step and 3-step polishing systems on the surface roughness and biaxial flexural strength of lithium disilicate ceramics after grinding. Settings and Design: Thirty-two 14 x 1.25 mm lithium disilicate (IPS e.max CAD) discs were…
-
Artikel Jurnal
Comparative evaluation of infrasinus residual ridge height in cone-beam computed tomography and on-site measurements during indirect sinus lift osteotomy: An observational study
Aim: To compare infra-sinus residual ridge height measured preoperatively using Cone-Beam Computed Tomography (CBCT) with intraoperative measurements recorded during indirect sinus lift osteotomy using the Crestal Approach Sinus (CAS) kit, and to evaluate the reliability of CBCT in posterior…
-
Artikel Jurnal
Accuracy of master casts fabricated for “all on 4” and “all on 6” implant situation in maxillary arch as influenced by the number of digital scan bodies: An in vitro comparative study
Aim: The aim of this study was to evaluate the effect of the number of intraoral scan bodies (ISBs) on the accuracy of digital impressions and the resulting master casts in full-arch maxillary implant rehabilitations in “all-on-4” and “all-on-6” situations. Settings and Design: This was an in vitro…
-
Artikel Jurnal
Effect of print orientation on the dimensional accuracy of three-dimensional-printed complete denture models: A comparative analysis of VAT photopolymerization and fused deposition modeling technologies
Aim: To evaluate the effect of print orientation (0°, 45°, and 90°) on the dimensional accuracy, precision, and production parameters of three-dimensional (3D) printed complete denture models fabricated using VAT photopolymerization and fused deposition modeling (FDM) technologies. Settings and…
-
Artikel Jurnal
Does resin cement choice influence the fracture strength of bonded lithium disilicate veneers? An ex vivo study
Aim: The aim of this study was to evaluate and compare the fracture strength of ceramic veneers bonded to natural teeth using different light-cure resin cements. Settings and Design: An ex vivo study. Materials and Methods: Thirty extracted human maxillary anterior teeth were collected and prepared…
-
Artikel Jurnal
Comparative evaluation of mechanical properties between dual-layer and bonded three-dimensional printed denture base materials: An in vitro study
Aim: The study aimed to compare the flexural strength, fracture toughness, and impact strength of the denture base materials fabricated using dual-layer and bonded 3D printing techniques. Settings and Design: In vitro comparative study. Materials and Methods: Seventy-two bar-shaped samples were…