661 results
Showing 1–20 · 0.21 seconds · RSS
Measurement Science Review
Scopus
ISSN 1335-8871 · Sciendo · 661 articles in the index
-
Journal Article
Identifying Key Factors in Human-Computer Interaction Through Feature-Based Analysis and Sensitivity Evaluation
For this experiment, Human-Computer Interaction (HCI) user interaction was forecasted by machine learning (ML) classification models, Random Forest Classification (RFC), and Decision Tree Classification (DTC). Two metaheuristic optimization algorithms, Fox Optimizer (FO) and Northern Goshawk…
-
Journal Article
Numerical Calculation and Experimental Study of a Large-Format Streak Tube with High Spatiotemporal Resolution
Large-format streak tubes with high spatiotemporal resolution are essential for ultrafast diagnostic systems, such as inertial confinement fusion (ICF) experiments, compressed ultrafast photography (CUP), and imaging lidar. However, simultaneously achieving a large working area on the photocathode…
-
Journal Article
Rapid Touchless 3D Fingerprint Imaging Based on Full-field Microscopic Fringe Projection Technique
Accurate three-dimensional (3D) fingerprint imaging is essential for next-generation biometric systems requiring high spatial resolution and microfeature fidelity. This study presents a novel, rapid, non-contact 3D fingerprint imaging system that integrates a seven-step phase-shifting fringe…
-
Journal Article
Standardization of Measurement and Imaging Protocols in Magnetic Resonance: An Overview of Current Initiatives, Challenges, and Perspectives
Magnetic resonance imaging (MRI) is one of the most important imaging modalities in clinical diagnostics and biomedical research; however, its usability is significantly limited by the high technical and methodological variability across sites, scanners, and acquisition protocols. This lack of…
-
Journal Article
Measurements of Potential Positive Ion Sources of Gadolinium
The long-term goal of the research is to develop a positive (Gd II) ion source for further experiments, particularly for the studies of negative ions. Gadolinium (Gd) is a hardly volatile element (melting temperature 1585 K, boiling point 3273 K) with metallic properties; therefore, the atomization…
-
Journal Article
An Analytical Solution for the Eddy Current Coil Located over a Conductive Disc with Two Layers of Different Radii
In this work, an analytical model was derived for an air-core probe placed above a disc whose upper layer has a larger diameter than the lower layer. The proposed solution can be utilised in eddy current testing of screws, rivets, valves, and other elements with similar geometry, and made of…
-
Journal Article
Low-Frequency Noise Measurement of High-Ohm Resistors
This paper addresses with the measurement of low-frequency noise in high-ohm resistors. The magnitude of low-frequency 1/f noise is primarily determined by the manufacturing technology of the resistor. In this paper, the noise of precise thick-film resistors was compared with the noise of…
-
Journal Article
Numerical Solutions for Nonlinear Vibrations of the Mathematical Pendulum Based on a Modified Frequency Formulation: Location Point Configurations
This paper aims to obtain accurate and efficient numerical solutions for the nonlinear vibrations of a mathematical pendulum using a modified frequency formulation, with a focus on the optimal design of location point configurations. The nonlinear motion equation of the pendulum is transformed to…
-
Journal Article
Sensor of Mechanical Quantity Based on the RF Principle
This paper presents the design and analysis of a mechanical quantity sensor based on a radio-frequency principle, while addressing the high power consumption and circuit complexity of existing solutions. The proposed approach focuses on minimizing power consumption and reducing the number of…
-
Journal Article
An Intraoperative Method for Measuring Acetabular Cup Inclination and Anteversion in Total Hip Arthroplasty Using an Inertial Measurement Unit
Aiming to guide acetabular cup placement within the “safe zone” (40°±10° inclination, 15°±10° anteversion), this paper introduces an intraoperative inertial measurement unit (IMU)-based method for measuring cup orientation in total hip arthroplasty (THA), featuring registration and measurement…
-
Journal Article
Methods and Practical Aspects of Measuring 1/f Noise in Zero-drift Operational Amplifiers
Operational amplifiers are an important ingredient of analogue electronic circuits, and their noise performance is an essential design parameter. However, at low frequencies, data provided by component manufacturers usually cover only a limited range (typically 0.1 Hz to 10 Hz). The frequencies…
-
Journal Article
BTS-NEUNET: Brain Tissue Segmentation via White Shark Optimized Features Based Nested U-Net
Segmenting brain tissue can provide valuable insights into its structure and function. Magnetic resonance imaging (MRI)-based tissue segmentation is an essential procedure for improving tractography and quantifying brain microstructure. In this work, a novel BTS-NEUNET framework is proposed for…
-
Journal Article
Pneumonia Detection from CXR using Adaptive Elephant Herd Optimization and Python Rectilinear Locomotion Strategy
Pneumonia poses a major global health challenge, impacting around 450 million individuals annually. This highlights the urgent need for computerized pneumonia detection using chest X-ray (CXR) images. Today, deep learning (DL) models are used to analyze CXR images for accurate pneumonia diagnosis…
-
Journal Article
The Uncertainty of the Indirect Thermographic Measurement of the Temperature of the Semiconductor Element
The indirect thermographic measurement of the temperature of a semiconductor element consists of two stages. The first involves a thermographic measurement of the case temperature of the semiconductor element. The second involves determining the relationship between the case temperature and the…
-
Journal Article
Accuracy Improvement of DIC Method Displacement Measurement Based on Image Stabilization
Digital image correlation (DIC) is a cornerstone technique for displacement measurement, offering transformative potential for structural health monitoring (SHM) applications due to its non-contact nature and cost-effectiveness. However, in practical applications, image jitter caused by extended…
-
Journal Article
Quality Assurance in the Calibration of Platinum Resistance Thermometers (Pt-100) at NIS
Ensuring the quality and accuracy of measurements is a critical aspect of the calibration process. One of the major challenges that calibration laboratories face is limited participation in international or bilateral comparisons and proficiency testing. This research aims to identify potential…
-
Journal Article
Accurate Frequency Detection Technology Based on Quantization Phase Accumulation Effect
To address the quantization phase accumulation effect caused by different frequency signals during phase comparison, an accurate frequency detection technology is presented. Through quantized phase analysis, statistics, and processing of the phase difference between the different frequency signals…
-
Journal Article
Analysis of the Influence of Selected Parameters on the Success Rate of Shotgun Firing on UAVs
In contemporary conflicts, land forces – including artillery units and even individual soldiers – have increasingly faced threats posed by small, inexpensive yet highly effective unmanned aerial systems (UAS). Even though extensive research has been conducted, it has proven challenging to support…
-
Journal Article
Development of a Time-Integration Method for Analyzing the Photoresponse of Image Sensors: Theoretical and Experimental Verification with Digital Cameras
This study introduces a novel method for analyzing image sensors, supported by both theoretical and experimental verification. We first theoretically derived that when sinusoidal light with constant amplitude is directed onto an image sensor with fixed exposure times, the radiant energy reaching…
-
Journal Article
Evaluation of Absorbing Material Shielding Effectiveness Using a Baum–Liu–Tesche Based Method
The shielding efficacy of the metal cavity can be effectively enhanced using absorbing materials coated on the inner wall of the cavity. With highly potential materials such as graphene, silicon carbide (SiC), polytetrafluoroethylene (PTFE), and Ni/rGO in shielding, an analytical method based on…