19 hasil
Menampilkan 1–19 · 0,21 detik · RSS
Chinese Journal of Electrical Engineering
Scopus
ISSN 2096-1529 · Editorial office of Chinese Journal of Electrical Engineering · 19 artikel di indeks
-
Artikel Jurnal
Design optimization and comparison of linear magnetic actuators under different topologies
In this study, several types of linear actuators that adopt different permanent-magnet (PM) topologies are studied and compared. These linear actuators are based on the concept of PM magnetic screw transmission, which offers high force density, high reliability, and overload protection. Using…
-
Artikel Jurnal
MESO-based robustness voltage sliding mode control for AC islanded microgrid
A new modified extended state observer (MESO)-based robustness voltage sliding mode control (SMC) strategy is proposed for an AC islanded microgrid under system uncertainties including system parameter and load variation. First, the disturbance effect on the system is regarded as a lumped…
-
Artikel Jurnal
Overview on submodule topologies, modeling, modulation, control schemes, fault diagnosis, and tolerant control strategies of modular multilevel converters
In the present scenario, modular multilevel converters (MMCs) are considered to be one of the most promising and effective topologies in the family of high-power converters because of their modular design and good scalability; MMCs are extensively used in high-voltage and high-power applications…
-
Artikel Jurnal
Capacity configuration of hybrid CSP/PV plant for economical application of solar energy
Concentrating solar power (CSP) technology has received increasing attention in recent years because of its distinct advantage for dispatchable power generation from solar energy. However, owing to its highly levelized costs of electricity, CSP plants are less competitive than photovoltaic (PV)…
-
Artikel Jurnal
Open-circuit fault diagnosis of traction inverter based on compressed sensing theory
This study proposes a new method of fault diagnosis based on the least squares support vector machine with gradient information (G-LS-SVM) to solve the insulated-gate bipolar transistor(IGBT) open-circuit failure problem of the traction inverter in a catenary power supply system. First, a…
-
Artikel Jurnal
Stability analysis of sampled-data control system and its application to electric power market
The stability of sampled-data systems is investigated using a new type of Lyapunov functional. The interval from the sampling point t k to t k+1 is assumed to be a sampling interval. By fully utilizing the characteristic information on the whole sampling interval, a new two-sided closed-loop…
-
Artikel Jurnal
Small signal stability of three-phase and six-phase synchronous motors: A comparative analysis
Small signal stability analysis is conducted for an asymmetrical six-phase synchronous motor in comparison with its equivalent three-phase counterpart. For this purpose, a linearized model of the six-phase synchronous motor is developed using the dq0 approach, which is used in eigenvalue criteria…
-
Artikel Jurnal
Control of UPQC based on steady state linear Kalman filter for compensation of power quality problems
A frequency lock loop (FLL) based steady state linear Kalman filter (SSLKF) for unified power quality conditioner (UPQC) control in three-phase systems is introduced. The SSLKF provides a highly accurate and fast estimation of grid frequency and the fundamental components (FCs) of the input…
-
Artikel Jurnal
Active disturbance rejection position servo control of PMSLM based on reduced-order extended state observer
To enhance the control accuracy of permanent magnet synchronous linear motor (PMSLM) servo systems affected by disturbances, such as time-varying parameters and abrupt load changes, an active disturbance rejection control (ADRC) algorithm based on a reduced-order extended state observer (ESO) is…
-
Artikel Jurnal
Review of parameter identification and sensorless control methods for synchronous reluctance machines
Synchronous reluctance machines (SynRMs) have drawn increasing attention in recent years owing to their advantages such as low cost, simple structure, ease of manufacture, and high robustness. The main obstacle to the promotion of SynRMs is severe parameter nonlinearity, which deteriorates drive…
-
Artikel Jurnal
Active power reserve photovoltaic virtual synchronization control technology
The photovoltaic virtual synchronous generator (PV-VSG) solves the problem of lack of inertia in the PV power-generation system. The existing PV plants without energy storage are required to participate in the power grid's frequency modulation (FM), but existing PV-VSGs with energy storage have…
-
Artikel Jurnal
Enhancing energy utilization efficiency of Pakistani system considering FACTS devices and distributed generation: Feasibility study
In recent years, voltage stability issues have become a serious concern with regard to the safety of electrical systems, these issues are more evident and have wider consequences in vertical networks with an insufficient reactive power reserve. Pakistan is currently suffering from the worst energy…
-
Artikel Jurnal
Reduction of high-frequency vibration noise for dual-branch three-phase permanent magnet synchronous motors
Two-level voltage source inverters with pulse width modulation (PWM) generate multiple carrier harmonics, thereby exciting high-frequency noise from the motor. Based on a special dual-branch three-phase permanent magnet synchronous motor (PMSM), a method that utilizes a known modified space vector…
-
Artikel Jurnal
An integrated reactive power control strategy for improving low voltage ride-through capability
Among all renewable energies, wind power is rapidly growing, whereby it has the most participation to supply power. Doubly fed induction generator (DFIG) is the most popular wind turbine, as it can play a very significant role to enhance low voltage ride through (LVRT) capability. Ancillary…
-
Artikel Jurnal
A missing power data filling method based on improved random forest algorithm
Missing data filling is a key step in power big data preprocessing, which helps to improve the quality and the utilization of electric power data. Due to the limitations of the traditional methods of filling missing data, an improved random forest filling algorithm is proposed. As a result of the…
-
Artikel Jurnal
Improved model predictive direct power control of grid side converter in weak grid using kalman filter and DSOGI
When grid side converter (GSC) is connected to weak grid, the small signal instability can happen due to terminal characteristics of the GSC that are incompatible with the grid impedance. This issue is not of wide concern in previous studies of direct power control (DPC) of GSC. By small signal…
-
Artikel Jurnal
Influence of magnet shape on the cogging torque of a surface-mounted permanent magnet motor
The influence of bread-loaf shaped magnet poles under parallel magnetization on the cogging torque of surface-mounted permanent magnet (SPM) motors is studied. For the SPM motors having magnetic poles with eccentricity and sine harmonic compensation, the electromagnetic performances of integer and…
-
Artikel Jurnal
Design and analysis of a wireless power transmission system with magnetic coupling resonance in the weak-coupling region
The magnetically coupled resonant wireless power transfer (MCR-WPT) system for implantable medical devices has gradually become one of the research hotspots. The transmission characteristics of the system in weak-coupling regions are of research significance. The mathematical model of the system's…
-
Artikel Jurnal
Vector control strategy of a T-type three-level converter driving a switched reluctance motor
A novel 12 voltage vector control strategy for switched reluctance motors (SRM) with a T-type three-level converter is proposed in this study. Based on a causal analysis of torque ripple under the control of conventional six voltage vectors, six new voltage vectors are added for further reduction…