728 hasil
Menampilkan 1–20 · 0,39 detik · RSS
EJNMMI Physics
Scopus
ISSN 2197-7364 · SpringerOpen · 728 artikel di indeks
-
Artikel Jurnal
SMGDiff: step mapping generalized diffusion model for efficient noise reduction in cardiac-gated myocardial perfusion SPECT images
Abstract Background Improving the image quality of cardiac gating myocardial perfusion single-photon emission computed tomography (CG MP-SPECT) is crucial for accurate diagnosis. Diffusion model (DM) has recently shown promise in MP-SPECT image denoising, but traditional DM typically require…
-
Artikel Jurnal
[177Lu]Lu-DOTA-TATE tumour and organ time-activity curves: prediction from a single-time-point [68Ga]Ga-DOTA-TATE PET/CT measurement
Abstract Aim Predicting the time-activity curve (TAC) of [177Lu]Lu-DOTA-TATE for organs at risk and neuroendocrine tumours (NETs) is an essential element in the calculation of the absorbed dose (AD) and a critical step for individualising peptide receptor radionuclide therapy (PRRT) treatment…
-
Artikel Jurnal
Clinical validation of a unified data-driven respiratory motion correction technique in 18F-FDG PET/CT imaging of upper abdominal lesions: a real-world study
Abstract Purpose Respiratory motion (RM)-related artifacts significantly impact image quality and diagnostic accuracy in PET/CT imaging. This study aimed to prospectively evaluate the clinical utility of the unified data-driven respiratory motion correction (uRMC) algorithm utilizing deep learning…
-
Artikel Jurnal
Quantitative performance of a 3D CZT and conventional SPECT/CT for Tb-161 imaging
Abstract Purpose This study aimed to assess the imaging performance of a 3D CZT SPECT/CT system for Tb-161 and compare its quantitative accuracy and image quality with those of a conventional [NaI(Tl)]-based SPECT/CT system. Methods A NEMA Image Quality (IQ) phantom was scanned with a 3D CZT…
-
Artikel Jurnal
Evaluation of precalculated attenuation correction map for preclinical cardiac PET/MR using a 1H/23Na surface coil
Abstract Background In preclinical PET/MR, attenuation correction (AC) uses a mix of pre-calculated attenuation maps accounting for animal cradles and organ segmentation obtained from whole-body MR using a volume coil. The development of X-nuclei such as 23Na or 31P may benefit from high…
-
Artikel Jurnal
It’s PET but not as we know it: radiation protection considerations when using a novel specimen PET-CT scanner during tumour resections for urology and head & neck patients
Abstract Purpose To evaluate the radiation protection requirements for a UK first specimen PET-CT scanner, the AURA10 (Xeos, Ghent), as assessed through a clinical trial investigating its use for intra-operative surgical margin assessment in urology and head and neck (H&N) tumour removal. Methods A…
-
Artikel Jurnal
Optimising $$^{90}Y$$ PET imaging for dosimetry in SIRT: insights from phantom and simulation studies on the Discovery MI scanner
Abstract Background The aim of this study was to optimise the acquisition and reconstruction parameters for $$^{90}Y$$ imaging on a digital PET scanner (Discovery MI 4-ring) under high (3 GBq), intermediate (1 GBq), and low (200 MBq) activity conditions. First, quantitative linearity was evaluated…
-
Artikel Jurnal
Data-efficient unsupervised deep learning deformable SPECT/CT registration framework for voxel-level radionuclide therapy dosimetry: validation using clinical 131I DTC therapy data
Abstract Purpose To develop a data-efficient, unsupervised deep learning framework for deformable SPECT/CT registration that supports voxel-based dosimetry in radionuclide therapy, particularly in clinical settings with limited imaging datasets. Methods We propose Nufit-Reg, an unsupervised deep…
-
Artikel Jurnal
Impact of reduced 18F-MK6240 PET/MR acquisition duration on image quality and tau pathology assessment in patients with cognitive impairment
Abstract Background ¹⁸F-MK6240 tau positron emission tomography (PET) is critical in Alzheimer’s disease diagnosis and therapeutic monitoring. However, the standard 20-minute static acquisition poses challenges for cognitively impaired patients with limited tolerance for prolonged scans. This study…
-
Artikel Jurnal
Denoising of 4D dynamic PET images using spatiotemporal regularization with integrated temporal restoration (SPRINTER)
Abstract Purpose High-quality 4D dynamic PET imaging is often compromised by noise, especially in low-count frames, which limits clinical utility and quantitative accuracy. This study proposes a novel spatiotemporal denoising method (SPRINTER) that integrates anatomical priors, self-supervised…
-
Artikel Jurnal
Estimation of effective half-life and lesion-specific kinetics in I-131 therapy for differentiated thyroid cancer using dual-timepoint imaging
Abstract Background Accurate estimation of lesion-specific effective half-life (Teff) is essential for patient-specific dosimetry in radioiodine (I-131) therapy for differentiated thyroid cancer (DTC). Although conventional multi-timepoint imaging provides detailed kinetic information, it is often…
-
Artikel Jurnal
A rapid total-body PET imaging approach for pediatric patients using non-attenuation-corrected PET scans
Abstract Background Pediatric lymphoma patients undergo multiple 18F-FDG PET/CT examinations for staging and response assessment, raising concerns about cumulative radiation dose, particularly from the CT component. We propose SnapPET, a CT-sparing deep learning–based framework that uses 2D…
-
Artikel Jurnal
Q.Clear reconstruction shortening the scanning time for 11C-CFT brain PET/MR imaging
Abstract Purpose As a tracer in brain PET imaging for diagnosis of Parkinson’s disease (PD), the application of 11C-methyl-N-2β-carbomethoxy-3β-(4-fluorophenyl)-tropane (11C-CFT) is limited due to its short half-life. This study aims to explore the feasibility of using Q.Clear reconstruction to…
-
Artikel Jurnal
Quantifying capillary transit time distribution: a novel tracer kinetic model accounting for leakiness, back diffusion, and perfusion in MRI and PET imaging—the outflow model
Abstract Background Brain blood perfusion is typically characterized through regional cerebral blood flow metrics. However, recent research demonstrates that the distribution of blood transit times through the capillary network also plays a significant role in physiological processes. Here, we…
-
Artikel Jurnal
Effective elimination of respiratory misregistration-induced attenuation correction errors in PET/CT via deep learning trained on data-driven gated PET from strictly respiratory-phase-matched PET/CT cases
Abstract Background In positron emission tomography (PET)/computed tomography (CT), CT is used for attenuation correction (AC). CT-based AC (CTAC) is susceptible to misregistration due to respiratory phase differences between CT and PET, frequently resulting in a “banana artifact (BA)”—an…
-
Artikel Jurnal
Improved patient models for simulation of clinically realistic 68Ga-SSTR PET and 177Lu-PRRT SPECT studies
Abstract Background The aim was to improve the realism of patient models for Monte-Carlo based evaluation of image-based quantification of tumour volume and activity in [68Ga]Ga-DOTA-TOC PET and [177Lu]Lu-DOTA-TATE SPECT images. Methods Three phantoms from the XCAT population were used as basis…
-
Artikel Jurnal
AI-based synthetic CT attenuation correction enables reliable quantitative SPECT in unilateral condylar hyperplasia
Abstract Purpose Unilateral condylar hyperplasia (UCH) is a rare mandibular growth disorder in which accurate assessment of condylar metabolic activity is essential for surgical decision-making. Quantitative 99mTc-methylene diphosphonate (MDP) SPECT/CT is commonly used for this purpose; however…
-
Artikel Jurnal
Multi-site distributed training with data protections for PET-based synthetic CT
Abstract Background Accurate PET quantification relies on attenuation correction (AC), commonly performed using a linear attenuation map derived from a CT acquisition. However, CT can introduce misregistration artifacts and adds radiation dose. Synthetic CT (sCT) from non-attenuation corrected…
-
Artikel Jurnal
Evaluation of segmentation accuracy and the improvement of time effectiveness using deep learning-based segmentation in 177Lu-DOTATATE dosimetry
Abstract Background The efficacy of deep learning-based artificial intelligence segmentation (AI-seg) in 177Lu-DOTATATE dosimetry remains underexplored. This study evaluates AI-seg’s contouring accuracy, dosimetric reliability, and time efficiency. Methods We analyzed 23 patients treated with…
-
Artikel Jurnal
Design and first experimental results of an edgeless PET prototype for breast imaging: DeepBreast
Abstract Background Breast cancer causes the largest number of cancer-related deaths among women worldwide. With the aim of improving Positron Emission Tomography (PET) technology for accurate breast cancer diagnosis and staging, we propose a system design based on monolithic crystals with inherent…