117 hasil
Menampilkan 1–20 · 0,93 detik · RSS
BMC Biomedical Engineering
ISSN 2524-4426 · BMC · 117 artikel di indeks
-
Artikel Jurnal
Performance of a wearable movement tracking system in detecting hypomobility in acute ischemic cerebrovascular events
Abstract Background Detecting new or worsening hypomobility in acute ischemic cerebrovascular patients is challenging, especially when asleep or unattended. This study used a wearable movement acceleration monitoring system to identify changes in these patients, aiming to improve early detection…
-
Artikel Jurnal
Performance of virtual unenhanced images on a prototype silicon photon counting detector CT: preliminary clinical results
Abstract Background To compare virtual unenhanced images (VUE) from a prototype deep silicon photon-counting detector computed tomography (PCD CT) system with true unenhanced images (TUE). Methods Five subjects including various anatomic structures were scanned on a prototype deep silicon PCD CT at…
-
Artikel Jurnal
ADHD classification using spherical phase space partitioning and symbolic time series analysis of multi-channel EEG signals
Abstract Attention Deficit Hyperactivity Disorder (ADHD) is one of the most common neurodevelopmental disorders in children, making early detection and intervention critically important. In this study, we propose a novel EEG based classification framework for ADHD that integrates advanced nonlinear…
-
Artikel Jurnal
Bench testing a contact sensing tracheal tube for monitoring the cuff–trachea interface
Abstract Cuffed tracheal tubes enable a secure airway during mechanical ventilation; however, improper cuff inflation can lead to complications such as inspiratory gas leaks, pulmonary ingress of orogastric secretions, or tracheal injury. This study explores a sensor-based approach to optimise cuff…
-
Artikel Jurnal
Multimodal data synchronization: a high-level software methodology for heterogeneous devices
Abstract Background Multimodal data acquisition from heterogeneous devices is frequently compromised by synchronization errors arising from clock skew and offset. Current solutions often necessitate complex external hardware or shared reference signals, which complicates deployment and limits…
-
Artikel Jurnal
Effect of seat cushion resilience and hardness on lower-limb loading during sit-to-stand
Abstract Background Seat cushion materials affect the mechanical demands of sit-to-stand (STS) movements; however, the effects of specific material properties, such as resilience and hardness, remain unclear. Understanding how these factors influence lower-limb joint moments and movement strategies…
-
Artikel Jurnal
Integrating statistical parametric mapping, functional principal component analysis, explainable machine learning, and equivalence testing for multimodal gait signal analysis
Abstract Background Gait speed is a key clinical indicator in neurological and orthopaedic conditions, yet waveform-level adaptations in ground reaction forces (GRF) and multi-muscle electromyography (EMG) remain poorly characterised. Existing approaches often analyse discrete outcomes or…
-
Artikel Jurnal
An edge-AI enabled wearable platform for real-time epileptic seizure detection with geolocated alerting
Abstract Epilepsy remains a major global health concern, particularly in regions where continuous medical monitoring is difficult to implement. This study introduces a wearable system powered by edge-based artificial intelligence, designed to detect epileptic seizures in real time. The device…
-
Artikel Jurnal
Development of a 3D-printed synthetic tracheal scaffold for partial tracheal wall reconstruction: an experimental animal study
Abstract Background Tracheal reconstruction remains a significant clinical challenge due to the difficulty of maintaining airway patency and promoting epithelial regeneration following tracheal injury or resection. Recent advances in tissue engineering have explored 3D-printed scaffolds as…
-
Artikel Jurnal
Comparative analysis of processed EEG indices and entropy-based metrics for assessing anesthetic depth: a scoping review - PRISMA-ScR
Abstract Background Processed electroencephalography (EEG) monitors such as the bispectral index (BIS) and patient state index (PSI), are used clinically to estimate anesthetic depth, yet their algorithmic design obscures how closely these indices reflect underlying neural complexity. Entropy-based…
-
Artikel Jurnal
Non-enzymatic sweat sensors for pediatric continuous glucose monitoring: a systematic review of engineering readiness and the cost-accuracy trade-off
Abstract Continuous glucose monitoring (CGM) in children with type 1 diabetes is faced with major challenges due to prohibitive price, invasiveness and lack of compliance with insulin of the currently available interstitial devices, which is particularly severe in low- and middle-income countries…
-
Artikel Jurnal
Linking neurological status to functional outcomes in spinal cord injury: a multi-class, task-specific approach
Abstract Background Spinal cord injury (SCI) causes long-term neurological deficits resulting in functional disabilities. While longitudinal recovery patterns of sensorimotor outcomes after SCI have been studied, few analyses have applied machine learning to systematically model the relationship…
-
Artikel Jurnal
Biomechanical evaluation of individual 3D-printed vertebrae
Abstract Background Personalized 3D-printed bone models are becoming increasingly popular in clinical care. Common applications include the visualization of idiopathic deformities or complex joint fractures. Functionalizing such printed replicas in terms of individual mechanical properties holds…
-
Artikel Jurnal
Quantifying mechanical and morphological properties of plantar foot soft tissues: a systematic review of techniques, methods and their clinimetric properties
Abstract Background Plantar foot soft tissues play a crucial role in absorbing and distributing mechanical stresses during weight-bearing activities. Accurate quantification of their mechanical and morphological properties is essential for understanding load distribution, tissue integrity, and…
-
Artikel Jurnal
Recent applications of chaos theory in medical sciences: progress and challenges
Abstract Background The application of chaos theory has positive results in different fields of science. Its nonlinear modeling properties and its vision of dynamic systems have enabled it to capture complex relationships in fields such as physics, financial econometrics, social systems and…
-
Artikel Jurnal
Feasibility study of an insole-type active assist device for ankle alignment correction during stepping in patients with knee osteoarthritis
Abstract Objectives This feasibility study aimed to examine whether an insole-type active assist device designed to dynamically adjust ankle alignment at heel contact can be safely delivered and evaluated during an on-the-spot stepping task in patients with medial knee osteoarthritis (OA). The…
-
Artikel Jurnal
Moving-average processing enables accurate quantification of time delay and compares the trending ability of cardiac output monitors with different response times
Abstract Background Continuous cardiac output (CCO) monitoring using pulmonary artery (PA) thermodilution and newly introduced beat-to-beat cardiac output (CO) monitoring technologies exhibits different response time delays. These differences can hinder accurate comparisons of their trending…
-
Artikel Jurnal
Diabetic retinopathy screening using machine learning: a systematic review
Abstract Diabetic retinopathy (DR) stands as a leading cause of global blindness. Early identification and prompt treatment are crucial in preventing vision impairment caused by diabetic retinopathy (DR). Manual screening of retinal fundus images is challenging and time-consuming. Additionally…
-
Artikel Jurnal
Identification of stiff-knee gait in stroke survivors
Abstract Background Stiff-knee gait is a common movement disorder in individuals with stroke; however, standardized criteria for its identification remain lacking. This study aimed to examine suitable criteria for identifying stiff-knee stroke survivors to facilitate comparisons across studies…
-
Artikel Jurnal
Effect of peroxybenzoic acid and hydroxybenzoic acid on allergic asthma
Abstract Objective Peroxybenzoic acid and hydroxybenzoic acid are phenolic compounds commonly used in cosmetics and pharmaceuticals that have shown potential as anti-inflammatory agents. We compared their effects on allergic airway inflammation and Th2 cytokine responses in a murine model of…