46 hasil
Menampilkan 1–20 · 0,53 detik · RSS
Frontiers in Lab on a Chip Technologies
ISSN 2813-3862 · Frontiers Media S.A. · 46 artikel di indeks
-
Artikel Jurnal
Integrating synthetic biology and laboratory-on-a-chip technologies for next-generation biosensors
Biosensors harness biological components to detect and report on specific analytes, offering crucial insights across medicine, environmental monitoring, agriculture, and food security. The convergence of synthetic biology and laboratory-on-a-chip (LoC) technologies is enabling a new generation of…
-
Artikel Jurnal
Approaches to enable vortex chromatography in silicon devices
Most analytical applications are run with conventional high-performance liquid chromatography (LC) technology, however the separation of highly complex mixtures is still challenging. One key challenge is to minimize band broadening caused by the velocity profile within the channel. Miniaturization…
-
Artikel Jurnal
Laser-welded elastomeric valves for the rapid fabrication of flow control in microfluidics
Precise flow control using valves is essential for the functionality of microfluidic systems as valves serve as critical components for regulating fluid pathways. This work presents a pneumatic elastomeric membrane-based valving mechanism integrated into microfluidic devices and demonstrates laser…
-
Artikel Jurnal
The added value of micro-nanotextured surfaces integrated in microfluidics and lab-on-a-chip
In the last 20 years, micro- and nano-textured surfaces have been produced by means of various surface engineering processes, imparting enhanced properties, such as tunable wettability from superhydrophilicity to superhydrophobicity, tunable optical, and antifouling or antibacterial properties, to…
-
Artikel Jurnal
Analytical solutions for electroosmotic core–annular flow of power-law fluids
Understanding electroosmotic flow of non-Newtonian fluids in micro- and nanochannels is crucial for the electrokinetic handling of chemical and biological samples that often exhibit viscoelastic, shear-thinning, or shear-thickening behavior. A theoretical model is developed for the generalized…
-
Artikel Jurnal
Transient electrophoresis of an oil drop
The transient electrophoresis of a weakly charged oil drop of viscosity ηd in an electrolyte solution of viscosity η is investigated theoretically on the basis of the Baygents–Saville model. An analytical expression for the electrophoretic mobility in the Laplace domain is derived, from which an…
-
Artikel Jurnal
Droplet microfluidics for energy and bioelectrochemical applications
Droplet microfluidics has become a modern technology for chemical, biological, electrochemical and energy applications, which helps in the manipulation of a discrete droplet in a size range from 10 pL to 100 nL. Compared to conventional techniques, the droplet-based platform provides a 10–100-fold…
-
Artikel Jurnal
A roll-to-roll fabricated lab-on-foil platform for point-of-care genetic detection of lactose intolerance: system design, integration and analytical validation
IntroductionWe present a lab-on-foil (LOF) microfluidic platform for point-of-care (POC) genetic testing, combining roll-to-roll UV nanoimprint lithography (R2R UV-NIL) with on-chip loop-mediated isothermal amplification (LAMP) and sequence-specific detection of single nucleotide polymorphisms…
-
Artikel Jurnal
Extracellular vesicle-integrated brain organoid-on-a-chip systems for neuroimmune communication and precision therapy in viral encephalitis
Viral encephalitis causes substantial neurological morbidity and mortality through the combined effects of direct viral injury, blood–brain barrier (BBB) dysfunction, and dysregulated communication among neural, vascular, and immune cells. Extracellular vesicles (EVs) are increasingly recognized as…
-
Artikel Jurnal
Plastic surface-immobilized primers for integrated DNA capture and purification in simplified molecular diagnostics - a proof-of-concept study
IntroductionCurrent molecular diagnostic (MDx) platforms rely on silica-coated surfaces for nucleic acid extraction. This requires multiple wash buffers and complex automation, thereby creating cost and usability barriers for resource-limited settings. Several modifications of MDx towards…
-
Artikel Jurnal
Wax transfer patterning of porous paper for lab-on-a-chip
Paper-based microfluidics has emerged as a promising platform for low-cost analytical and biological assays. However, fabrication of hydrophobic barriers on porous substrates remains largely dependent on direct wax printing, which limits patterning flexibility, requires specialized equipment, and…
-
Artikel Jurnal
A microfluidic distillation system for rapid separation of sorbic acid from complex food matrices
IntroductionSorbic acid (SA) is widely applied as an antimicrobial preservative in processed foods, but its reliable determination remains difficult when complex matrices interfere with direct instrumental analysis. Conventional steam distillation can remove these interferences, although the…
-
Artikel Jurnal
Toward aptamer-enabled continuous health monitoring: challenges and opportunities
Continuous health monitoring has the potential to transform disease management by moving biomarker measurements from episodic testing to real-time tracking. Aptamers are promising affinity reagents for this purpose because they can recognize a wide range of targets and can be chemically…
-
Artikel Jurnal
Optimizing diagnostic procurement and waste management in low- and middle-income countries during emerging infectious disease threats: a scoping review
IntroductionTimely access to diagnostics is vital for detecting and controlling emerging infectious diseases. However, the procurement, utilization, and waste management of diagnostic devices in low- and middle-income countries (LMICs) remains a significant challenge. This scoping review study…
-
Artikel Jurnal
From lab to fab: overcoming the design–manufacture divide in microfluidic product development
Microfluidic technologies underpin many advances in diagnostics and life-science tools, yet only a minority of laboratory concepts survive the transition to manufacturable products. Drawing on development experience across multiple industry-facing projects within the Microfluidics Innovation Hub…
-
Artikel Jurnal
Bio-based materials: an alternative to synthetic polymers for the development of lab-on-a-chip devices
Lab-on-a-chip (LoC) devices have proved their potential for biomedical and analytical applications. Despite their growing demand, their environmental impacts remain insufficiently taken into account. These microfluidic devices are mainly made from petroleum-based materials like PDMS and…
-
Artikel Jurnal
Engineering liver organoids-on-a-chip
Advances in stem cell biology and microengineering have led to the emergence of liver organoids-on-a-chip systems, hybrid platforms that integrate self-organizing three-dimensional organoids with microfluidic devices. These technologies enable more physiologically relevant modeling of human liver…
-
Artikel Jurnal
Towards sustainable diagnostics: assessing biodegradable lateral flow cassettes in real world conditions in Africa
IntroductionThe widespread use of Lateral Flow Assays (LFAs) has significantly improved diagnostic accessibility in low- and middle-income regions, yet their reliance on single-use plastic cassettes poses urgent environmental concerns as conventional plastics persist for centuries, degrading only…
-
Artikel Jurnal
The environmental footprint of point-of-care diagnostics: quantitative review and a practical eco-design metric
Single-use biosensors such as lateral flow assays (LFAs) have transformed point-of-care (PoC) diagnostics, yet their environmental footprint is rarely considered during design. As deployment scales globally, this oversight raises pressing sustainability concerns. Although early integration of…
-
Artikel Jurnal
Organs-on-a-chip for global equity: a perspective from Guatemala on advancing biomedical research in resource-limited settings
Animal models have long supported biomedical research, particularly in the development of drugs and preclinical testing. Yet, persistent discrepancies between animal data and human clinical outcomes have prompted a critical reassessment of their translational value. Challenges, including biological…