87 hasil
Menampilkan 1–20 · 0,35 detik · RSS
JTCVS Structural and Endovascular
Scopus
ISSN 2950-6050 · Elsevier · 87 artikel di indeks
-
Artikel Jurnal
Enhanced recovery after surgery turnkey order set for periprocedural care of the patient undergoing transcatheter aortic valve replacement
Objective: Transcatheter aortic valve replacement is now a leading treatment for severe symptomatic aortic stenosis across the risk spectrum. The choice between transcatheter and surgical aortic valve replacement remains a shared decision, particularly for patients aged 65 to 80 years. Despite…
-
Artikel Jurnal
Prognostic value of endothelial activation and stress index (EASIX) on short-term and long-term outcomes in type B aortic dissection after thoracic endovascular repair: An observational study
Objective: The association between endothelial activation and stress index (EASIX) and both short-term and long-term outcomes in patients with type B aortic dissection (TBAD) undergoing thoracic endovascular repair (TEVAR) remains unclear. This study aimed to explore this relationship. Methods: We…
-
Artikel Jurnal
Impact of downtime on surgical outcomes after repair of acute type A aortic dissection presenting with cardiopulmonary arrest
Objective: The management of acute type A aortic dissection with cardiopulmonary arrest remains controversial. We evaluated the impact of downtime on outcomes after aortic repair in this high-risk population. Methods: We retrospectively reviewed 711 patients with acute type A aortic dissection…
-
Artikel Jurnal
Hospital volume and efficiency in transcarotid transcatheter aortic valve replacement: Insights from a national database of 10,000+ cases
Background: When transfemoral transcatheter aortic valve replacement (TAVR) is unsuitable, transcarotid TAVR offers a safe alternative. The relationship between hospital procedural volume and clinical outcomes remains unclear, and solidifying this relationship is key to establishing benchmarks and…
-
Artikel Jurnal
Balloon tamponade for central venous catheter–related perforations: A minimally invasive, vessel-sparing case series
Objective: Iatrogenic central venous injuries are rare but potentially catastrophic complications of catheter-based interventions. Management options remain limited, with surgical repair often infeasible in high-risk patients and covered stents associated with infection risk and permanent loss of…
-
Artikel Jurnal
Outcomes, survival, mortality, and major adverse events in aortic valve replacement surgeries in Africa: A systematic review and meta-analysis
Objectives: Aortic valve replacement (AVR) is the definitive treatment for severe aortic valve disease, yet outcome data from Africa remain scarce. This systematic review and meta-analysis assessed survival, mortality, and major adverse events after AVR across Africa. Methods: Adhering to Preferred…
-
Artikel Jurnal
Acute left ventricular unloading in chronic ovine biventricular failure with functional tricuspid regurgitation
Objectives: Right ventricular failure and functional tricuspid regurgitation are associated with left ventricular assist device implantation. We set out to investigate the effect of acute left ventricular unloading on right ventricular subvalvular geometry in the setting of ovine biventricular…
-
Artikel Jurnal
Deep learning for predicting transvalvular gradient outcomes for patients undergoing transcatheter aortic valve replacement for native aortic stenosis
Objectives: To develop a deep learning-based predictive model for preprocedurally predicting post-transcatheter aortic valve replacement (TAVR) gradient waveform using pre-TAVR echocardiographic information only for candidates for both balloon-expandable and self-expandable THV in a TAVR procedure…
-
Artikel Jurnal
Transcatheter aortic valve canting creates cusp-specific thrombogenic microenvironments through altered sinus hemodynamics
Objectives: Transcatheter aortic valve replacement has transformed the management of aortic stenosis; however, leaflet thrombosis and hypoattenuated leaflet thickening remain major clinical concerns. Flow disturbances from valve canting may alter local hemodynamics and promote thrombogenic…
-
Artikel Jurnal
Total endovascular repair using a branched endograft for thoracic aortic arch aneurysm: A single-center experienceCentral MessagePerspective
Objective: Thoracic endovascular aortic repair (TEVAR) for aortic arch aneurysms remains technically challenging because of supra-aortic vessel involvement and complex arch anatomy. This study evaluated the feasibility and outcomes of branched TEVAR using fenestrated stent grafts in conjunction…
-
Artikel Jurnal
Surgical management of infected thoracic endografts: A single-center experienceCentral MessagePerspective
Objective: Thoracic endovascular aortic repair is the preferred approach for treating pathology of the descending thoracic aorta. Infection after thoracic endovascular aortic repair is reported to occur in less than 1% of patients and is associated with significant mortality. The purpose of the…
-
Artikel Jurnal
Endovascular repair of diseases originating in the ascending thoracic aorta: A systematic review and meta-analysisCentral MessagePerspective
Objective: This report provides a concise overview of the published literature and clinical outcomes on ascending thoracic endovascular aortic repair (aTEVAR) for diseases originating in, but not restricted to, the ascending aorta. Methods: PubMed, Scopus, and Web of Science were systematically…
-
Artikel Jurnal
Elective interval thoracic endovascular aortic repair versus medical management for uncomplicated type B aortic dissection among Medicare patientsCentral MessagePerspective
Objective: To compare elective interval thoracic endovascular aortic repair (TEVAR) with ongoing medical management (MM) within 90 days for uncomplicated type B aortic dissection (uTBAD). Methods: Medicare MedPar files from 2001 to 2020 were queried for patients with acute uTBAD who were discharged…
-
Artikel Jurnal
Three-year outcomes of endovascular repair of descending thoracic aortic lesions with a single-branched endograft for left subclavian artery preservationCentral MessagePerspective
Objective: Zone 2 thoracic endovascular aortic repair with a single-branched endograft (GORE TAG Thoracic Branch Endoprosthesis [TBE], W.L. Gore & Associates, Inc) was approved by the Food and Drug Administration in May 2022 on the basis of 1-year results from a pivotal trial. This report presents…
-
Artikel Jurnal
Outcome of cerebral embolic protection during transcatheter aortic valve replacement in high-risk patient for strokeCentral MessagePerspective
Objectives: The sentinel cerebral embolic protection device has been used as prophylaxis of stroke and transient ischemic attack during transcatheter aortic valve replacement. However, there are no absolute criteria guiding cerebral embolic protection device placement. This study aimed to evaluate…